P a g e
|
7
Basic Keypad Programming
0
0
0
0
*
*
Quick start guide
1) Enter programming mode (amber LED should be ON)
1
0
2
0
0
?
?
?
?
#
0
2) Enter a new user code...
*
*
3) Exit programming mode
4) Enter the new user code to check the relay clicks.
Full Keypad programming
Enter programming mode..
0
0
0
0
*
*
Exit programming mode..
*
*
Enter a new ENGINEERS code…
Go into programming mode firstly then enter the following sequence…
Location
0
1
?
?
?
?
4-8 digit code
Validate
#
Enter or delete new user codes
There are 3 groups of user codes. Group 10 for relay 1, group 20 for relay 2, and group 30 for
relay 3. The programming sequence is shown below…
Memory locations
000-999 for relay 1
001-100 for relay 2
001-100 for relay 3
1
0
2
0
0
10
= relay 1 codes
(1000 available)
20
= relay 2 codes
(100 available)
30
= relay 3 codes
(100 available)
?
?
?
?
#
0
2= add code
5= delete code
Pin code 4-8 digits
Validate
Example: Add user 31 to have access code 5555 operating relay 2….
2
0
2
0
3
5
5
5
5
#
1
Group 2
Add code
Location 31
Pin code 5555
Validate
Tip:
The engineer code
must be the same length as
user codes. So if using a 6
digit engineers code, then
user codes must also be 6
digits long etc.
The unit is now in programming mode. Amber LED on the
keypad should remain permanently on. 0000 is the default
programming passcode.
The unit should exit programming mode and the amber LED
should start flashing again.
Replace ???? with your new ENGINEERS
code.
Содержание 603 FB