background image

P a g e

 | 

25

 

9999

#

73

*

#

 

Delete all caller ID numbers 

N/A 

Service & diagnostic messages (no passcode required for some of these!) 

*

20

Check reception level 1-31 (no passcode needed) 

N/A 

*

21

Check stored numbers. O = dial out number. I = dial in 
number. E = end of message. (no passcode needed) 

N/A 

*

22

Check input status and relay status. (No passcode needed) 

N/A 

*

23

Sends SMS messages of the last 20 events. 

N/A 

1234

#

25

Check stored keypad codes. 

N/A 

Keypad Programming 

9999

#

 

81X

code

#

time

Permanent codes

 - X=1 or 2 for relay 1 or 2. Code = 4-6 

digits. Time = 1-9999 seconds, or 0 for latching code. 

N/A 

9999

#

 

83

#

day,day,day 

#

time1,time2

#

 

code

Time restricted codes 

Day = day of the week e.g. mon,tue,wed,thur,fri.  
Time1 = start time. Time2 = end time (24 hr format, no colon. 
E.g. 11:30pm = 2330. 8.30am = 0830. 
Code = pin code 4-6 digits. 

N/A 

9999

#

 

82

#

hours

#

 

code

Temporary codes  

Hours = time to expire in hours (1-168 hours). 
Code = Pin code 4-6 digit code. 

N/A 

9999

#

84

code

Delete code

 

– Code=known code to be deleted. 

N/A 

9999

#

84

*

Delete all codes. 

N/A 

Notifications 

9999

#

80

X

X=1 to disable. X=2 to enable. 

N/A 

9999

#

78

XXX

X=phone number to send notifications to. (*=delete number) 

N/A 

9999

#

79

text

X=text to send to the receiving 

phone e.g. “gate opened” 

N/A 

Automatic Time Clock Trigger Times 

1234

#

X

day,day,day

time

#

 

X=1,2.3 (trigger, latch, unlatch relay 1) 4,5,6 (relay 2) 
Day = days of the week (mon,tue,wed,thur,fri,sat,sun) 
Time = time of day (24 hr format, no colon. E.g. 8:30am = 
0830) 

N/A 

1234

*

X

Delete ALL automatic trigger times. 

N/A 

Clock Sync - Auto Time Calibration after Power Fail 

9999

#

86

XXX

X=telephone number of SIM inside the intercom. 

N/A 

9999

#

86

*

Delete the phone number. 

N/A 

Summer Daylight Auto Correct 

9999

#

87

??

?? = number of days between SMS calibration SMS should 
be sent. 0 = no message sending. 

N/A 

Do Not Disturb (push button de-activated during set times) 

1234

#

21

#

ON

#

  

 

ON = activated. OFF = de-activated. 

OFF 

9999

#

 

21

#

day,day,day 

#

time1,time2

Enter all active days during which button should operate. 
Enter start and end time button should operate  
(24 hr format, no colon. E.G 8:30am = 0830) 

N/A 

 

Содержание Cellcom Prime 5AB

Страница 1: ...ONAL INSTALL ONLY Do NOT give this manual to the end user home owner GSM Intercom System Models 5AB 5ABK 5AS 5ASK 5HS 5HSK 5HB 5HBK 5FB 5FBK 5IMP 5IMPK Manual Version 3 Scan QR code below to download...

Страница 2: ...s Control Pg 9 Internal Clock Pg 9 Winter Summer Daylight Saving Pg 10 Do Not Disturb Pg 10 Out of Hours Pg 10 Programming Keypad Codes Permanent Codes Pg 11 Temporary Codes Pg 11 Time Restricted Code...

Страница 3: ...ets and will not work in the unit Power TIP Most technical calls received are due to installers using CAT5 or alarm cable to power the unit Neither are rated to carry enough power 2 amp peak Please us...

Страница 4: ...de View Flush Panels Call Button Optional keypad module Remove Side View Flush with surface Tip Use appropriate fixings to ensure the intercom cannot be removed from the wall Do not remove the protect...

Страница 5: ...d Pre wired to push button Optional exit button triggers output 1 for programmed time 24v DC Optional gate position limit switch Relay outputs Signal LED CPU Power Micro SIM Insert this way Please ens...

Страница 6: ...ing 1 bar signal 2 bars signal 3 bars signal 4 bars signal System booted Booting TIPS My GSM LED is still searching Check the SIM card is registered and can make a call in a phone Check the SIM card i...

Страница 7: ...apple devices you can download the AES programming app called Cellcom Prime Programmer or scan QR code below 2 Open the app and allow all permissions Android users Register your details first time fo...

Страница 8: ...all 1 Go to MORE CLIENT LIST to reveal the screen shown 2 Press and HOLD to select the desired client 3 Iphone users press the info symbol Android users press and hold the client and then press upload...

Страница 9: ...be taken to their SMS screen to confirm before sending the string The intercom should then reply with a signal level between 1 and 31 1 12 Poor 13 20 Medium 21 31 Good For good performance signal leve...

Страница 10: ...for a 10 button system 2 Simply enter cell phone numbers and or landline phones which the intercom is to call when the call button is pressed 10 button model please enter button number 3 Press SAVE No...

Страница 11: ...time 3 Press SAVE Note iphone users will be taken to their SMS screen to confirm the SMS string press send 4 The intercom should reply with an SMS to your phone showing the SMS string and an OK statu...

Страница 12: ...igger times etc Mic SPK Volume Avoid voicemail picking up un answered calls Service Calls prevent SIM being turned off due to inactivity Diagnostics Programmer and user pass codes Default relay pulse...

Страница 13: ...lling Times Talk Time Change ringing times on each number to avoid voicemail picking up a call on un answered call so the unit can roll over to the next number Note Default 20 secs includes 5 8 sec co...

Страница 14: ...ll call or SMS at the time at which the feature was activated So if you set this feature up at 5pm it will make the service call or SMS at 5pm at the next interval SMS string for choosing SMS or CALL...

Страница 15: ...tus of the input terminals called STATUS on the intercom can be used with a limit switch Relay status shown to check if any relay is latched Last 5 digits of phone number which answered the gate Last...

Страница 16: ...any further programming If the 1234 user access code is changed then you will also need to change it on the home owners app SMS Strings 9999 01XXXX X new programmers code 9999 02XXXX X new user acces...

Страница 17: ...ed to trigger the gates and grant access Quick Enable disable this feature Enter the phone number to receive the SMS alert and press SAVE Enter text which you want the user to receive when access is g...

Страница 18: ...ecs for 1 hour hold open on gates SMS String for adding keypad codes 9999 811code time Pass code Function code 4 digit user code 1 Relay 1 2 Relay 2 SECONDS 1 9999 0 Latching Enter 4 digit code Enter...

Страница 19: ...String for temporary code 9999 82 hours code Pass code Function code Can be between 1 168 hours 4 digit code Delete Codes You can use these buttons to delete a recently stored temp or time restricted...

Страница 20: ...entary latch unlatch 2 Choose the days 3 Enter the time in military 24hr format without colon E g 8 30am 0830 11 10pm 2310 1234 1 day day day time USER passcode Command 1 trigger relay 1 2 latch relay...

Страница 21: ...ular power cuts and your client is using timed features Note Using this feature will cause the unit to be busy for 2 3 minutes after a reboot Please be patient with programming etc after a re boot 999...

Страница 22: ...digit format no colon and separate with comma e g 0800 2300 Select days up to 7 3 digit format separate with commas E g mon tue wed thu fri To activate enter the following code 1234 21 ON change ON t...

Страница 23: ...call a different number after hours For example in commercial premises it can call the office phones during business hours and then call a security guard after hours 1 Enter phone number to call after...

Страница 24: ...number adjust this to avoid voicemail picking up a call 10 99 secs 20 secs 9999 46 Calling time for second number adjust this to avoid voicemail picking up a call 10 99 secs 20 secs 9999 47 Calling ti...

Страница 25: ...84code Delete code Code known code to be deleted N A 9999 84 Delete all codes N A Notifications 9999 80X X 1 to disable X 2 to enable N A 9999 78XXX X phone number to send notifications to delete num...

Страница 26: ...o thin Refer to manual for guidelines 2 Not responding to SMS messages and not making outgoing calls A No credit on SIM card A Power cable not within spec Refer to manual for guidelines 3 Not triggeri...

Страница 27: ...r in kits 1 2 2 Software feature added for call log to show last 25 caller ID calls 1 3 2 Main capacitor regulator diode upgraded for 24v ac 1 4 2 Micro Sim Holder and complete board respin 1 4 3 Call...

Страница 28: ...P a g e 28...

Отзывы: