P a g e
|
25
9999
#
73
*
#
Delete all caller ID numbers
N/A
Service & diagnostic messages (no passcode required for some of these!)
*
20
#
Check reception level 1-31 (no passcode needed)
N/A
*
21
#
Check stored numbers. O = dial out number. I = dial in
number. E = end of message. (no passcode needed)
N/A
*
22
#
Check input status and relay status. (No passcode needed)
N/A
*
23
#
Sends SMS messages of the last 20 events.
N/A
1234
#
25
#
Check stored keypad codes.
N/A
Keypad Programming
9999
#
81X
code
#
time
#
Permanent codes
- X=1 or 2 for relay 1 or 2. Code = 4-6
digits. Time = 1-9999 seconds, or 0 for latching code.
N/A
9999
#
83
#
day,day,day
#
time1,time2
#
code
#
Time restricted codes
Day = day of the week e.g. mon,tue,wed,thur,fri.
Time1 = start time. Time2 = end time (24 hr format, no colon.
E.g. 11:30pm = 2330. 8.30am = 0830.
Code = pin code 4-6 digits.
N/A
9999
#
82
#
hours
#
code
#
Temporary codes
Hours = time to expire in hours (1-168 hours).
Code = Pin code 4-6 digit code.
N/A
9999
#
84
code
#
Delete code
– Code=known code to be deleted.
N/A
9999
#
84
*
#
Delete all codes.
N/A
Notifications
9999
#
80
X
#
X=1 to disable. X=2 to enable.
N/A
9999
#
78
XXX
#
X=phone number to send notifications to. (*=delete number)
N/A
9999
#
79
text
#
X=text to send to the receiving
phone e.g. “gate opened”
N/A
Automatic Time Clock Trigger Times
1234
#
X
#
day,day,day
#
time
#
X=1,2.3 (trigger, latch, unlatch relay 1) 4,5,6 (relay 2)
Day = days of the week (mon,tue,wed,thur,fri,sat,sun)
Time = time of day (24 hr format, no colon. E.g. 8:30am =
0830)
N/A
1234
*
X
#
Delete ALL automatic trigger times.
N/A
Clock Sync - Auto Time Calibration after Power Fail
9999
#
86
XXX
#
X=telephone number of SIM inside the intercom.
N/A
9999
#
86
*
#
Delete the phone number.
N/A
Summer Daylight Auto Correct
9999
#
87
??
#
?? = number of days between SMS calibration SMS should
be sent. 0 = no message sending.
N/A
Do Not Disturb (push button de-activated during set times)
1234
#
21
#
ON
#
ON = activated. OFF = de-activated.
OFF
9999
#
21
#
day,day,day
#
time1,time2
#
Enter all active days during which button should operate.
Enter start and end time button should operate
(24 hr format, no colon. E.G 8:30am = 0830)
N/A
Содержание Cellcom Prime 5AB