P a g e
|
18
Permanent Keypad Code
Stores up to 200 codes, all of which can be used to gain
access 24/7.
Time (Restricted) Code
Stores up to 20 codes which will only work during pre-set
times and days of the week. (Relay 1 only).
Enter 4 digit code
Choose Relay 1 or Relay 2
Enter activation time. (0-9999 seconds)
Use 1 second for gate trigger.
Use approx. 5 secs for magnetic locks.
Use 0 for latching or toggle code.
Use 3600 secs for 1 hour hold open on gates
SMS String for adding keypad codes:
9999
#
81
1
code
#
time
#
Pass code
Function
code
4 digit user
code
1 = Relay 1
2 = Relay 2
=SECONDS
1-9999
0 = Latching
Enter 4 digit code
Enter Start and Finish time
(Military format without any colons.
E.g. 8am = 0800. 11pm = 2300)
Select days of the week the code is to
be active.
SMS String for time restricted code:
9999
#
83
#
day,day,day
#
time1,time2
#
code
#
Pass code
Function code
Enter start and end time in
24hr 4 digit format (no
colon), and separate with
comma. e.g. 0800,2300
Select days (up to 7)
3 digit format, separate
with commas.
E.g. mon,tue,wed,thu,fri
4 digit code
Содержание Cellcom Prime 5AB