C. C2 will be displayed. With the control in this position,
check to see that the water is being drawn out of the
regenerant tank. The water level in the regenerant
tank should recede very slowly.
D. Observe that water is being drawn from the
regenerant tank for at least three minutes. If the
water level does not recede, check all regenerant line
connections for air leaks.
8. If the water level is receding from the regenerant tank, you
can quick cycle the control back to the treated water position
by pressing SET and the UP buttons simultaneously.
9. Finally, turn on a faucet plumbed after the water conditioner.
Run the faucet until the water runs clear.
10. Add the appropriate amount of regenerant to the regenerant
tank.
The Water Conditioning System
is Now Fully Operational.
Placing WC400 Water Conditioning System
Into Operation (Fill Brine Tank First)
Quick Cycling the Analyzer Control
It is required that the control be quick cycled to specific
regeneration cycles when placing the conditioner into operation.
Please review the following instructions for quick cycling the
control before proceeding to startup.
1. With the control in the treated water position, press and
hold the REGEN button on the control for five seconds. This
will initiate a manual regeneration. The control will display
an hourglass indicating that the motor and camshaft are
turning. The control also displays the total regeneration time
remaining. When the control reaches the pre-pressurize cycle,
the hourglass is no longer displayed and the motor will turn
off. Pressing the SET button will display the time remaining
for the current cycle.
2. Press and release the UP and SET buttons to move the control
to the next cycle.
Note:
The control can be sent directly back to the treated
water position from any regeneration cycle. Press and hold the
UP and SET buttons (about five seconds) until the hourglass
icon appears solid. The control will now skip all remaining
regeneration cycles.
Startup
After you have performed the previous initial power-up steps,
you will need to place the conditioner into operation. Follow
these steps carefully, as they differ from previous WC400 valve
instructions.
1. Remove the cover from the valve. Removing the cover will
allow you to see that the camshaft is turning, and in which
cycle the camshaft is currently positioned.
2. With the supply water for the system still turned off, position
the bypass valve to the “not in bypass” (normal operation)
position.
3. Press and hold the REGEN button on the Analyzer control for
five seconds. This will initiate a manual regeneration. The
control will display an hourglass indicating that the motor
and camshaft are turning. The control also displays the total
regeneration time remaining. When the control reaches the
repressurize cycle (C4), the hourglass is no longer displayed
and the motor will turn off. Pressing the SET button will
display the time remaining for the current cycle.
4. Press and release SET and UP simultaneously to advance
to each cycle.
5. Advance the control to the Backwash cycle (C1).
See Cycle Sequence Table.
Cycle Sequence Table
C#
Cycle Description
Time in Minutes
C0
Service
C4*
Repressurize
3
C8
Brine Refill
Calculated
C0
Brine Make-up
120
C1
Backwash
14
C2
Brine Draw
Calculated
C3
Slow Rinse
Calculated
C4*
2nd Repressurize
3
C5
Fast Rinse
6
C6
2nd Backwash
1
C7
2nd Fast Rinse
1
*Note: C4 repressurization does not have flow to drain.
6. Fill the media tank with water.
A. While the controller is in the backwash (C1)
cycle, open the water supply valve very slowly
to approximately the 1/4 open position.
WARNING:
If opened too rapidly or too far,
media may be lost out of the tank into the valve
or the plumbing. In the 1/4 open position, you
should hear air slowly escaping from the valve
drain line.
B. When all of the air has been purged from the media
tank (water begins to flow steadily from the drain
line), open the main supply valve all of the way. This
will purge the remaining air from the tank.
C. Allow water to run to drain until the water runs clear
from the drain line. This purges any refuse from the
media bed.
D. Turn off the water supply and let the system stand for
about five minutes. This will allow any air trapped to
escape from the tank.
7. Add water to the regenerant tank (conditioner only).
A. With a bucket or hose, add enough water to the
regenerant tank to have water visible.