background image

it in case scalding. 
3. Do not put metal objects into the inverter, this could cause electric shock. 
4. Do not touch the metal of the socket while insert the plug to the socket of the 
inverter. 
5. Keep the inverter away from explosives.   
6. Keep all AC electric equipment away from the inverter, it will damage the 
inverter and also may cause electric shock.   

 

Protect function and Restart work method; 

State description 

Function 

LED light 

Alarm 

AC output 

Restart work method 

Input low 

voltage 

alarm 

Green on 

Red off 

Alarm   

AC has output 

When the voltage of 
the battery returns to 
the related range, the 
alarm will stop 
automatically 
 

Input low 

voltage shut 

down 

Green on 

Red on 

Alarm 

No AC output   

When the voltage of 
the battery returns to 
the related range, the 
inverter will start 
working, green light 
will go on, red light will 
go off. 

Input over 

voltage 

protection 

Green on 

Red on 

No 

alarm 

No AC output 

When the voltage of 
the battery returns to 
the related range, the 
inverter will start 
working, green light 
will go on, red light will 
go off. 

Over load 

protection 

Green on 

Red on 

No 

alarm 

No AC output 

Reduce the load to 
acceptable range the 
inverter will start 
working, green light 
will go on, red light will 
go off. 

Over 

temperature 

protection 

Green on 

Red on 

Alarm 

No AC output 

When the inside 
temperature returns to 
acceptable range the 
inverter will restart 
work, green light will 
go on, red light will go 
off. 

Output short 

circuit 

Green on 

Red off 

No 

alarm 

No AC output 

When short circuit 
removed, the inverter 
will start to work 
automatically 

 

Содержание FTS800

Страница 1: ...DC TO DC POWER INVERTER USER INSTRUCTION MANUAL Applicable for FTS800 FTS1000 FTS1500 ...

Страница 2: ...rsion efficiency It has five protection functions which include input under voltage protection input over voltage protection overload protection over temperature protection and output short circuit protection These five functions can protect the electrical equipment and the circuit of the car Please read instructions carefully before use Features and cable diagram 1 Fan 5 Fault light red light 2 D...

Страница 3: ...e red cable connect with terminal of the battery and the clip on the black connect with the terminal Do not reverse or it will destroy the power inverter d Turn on the power inverter the green light will on Insert the plug of the electric equipment into the AC socket of the inverter 3 Scope of application a Electrical equipment can be used Office equipment Computers printers facsimile printers sca...

Страница 4: ...g and after a short period where it has cooled down the inverter will restart working automatically 6 To save energy the fan will not work unless a The fan will work when the load exceeds 30 of the related power of the inverter b When the inside temperature of the inverter exceed 60 degree the fan will work 7 Extension cable use a We do not recommend the use of any extension cables between the inv...

Страница 5: ...Alarm No AC output When the voltage of the battery returns to the related range the inverter will start working green light will go on red light will go off Input over voltage protection Green on Red on No alarm No AC output When the voltage of the battery returns to the related range the inverter will start working green light will go on red light will go off Over load protection Green on Red on ...

Страница 6: ...1600W 2000W 3000W Output wave Modified sine wave Efficiency 80 No load current 0 35A 0 45A 0 45A Input under voltage alarm DC 10 2 10 8V Input under voltage shut down DC 9 2 9 8V Input over voltage shut down DC 15 16V Overload shut down 850W 1040W 1150W 1300W 1700W 1950W Fuse 25A 4 30A 4 30A 6 The best working temperature 5 35 Cooling method Fan Accessories Cigar cable Battery clip cable Technical...