DC TO DC
POWER INVERTER
USER INSTRUCTION MANUAL
Applicable for: FTS800/FTS1000/FTS1500
Страница 1: ...DC TO DC POWER INVERTER USER INSTRUCTION MANUAL Applicable for FTS800 FTS1000 FTS1500 ...
Страница 2: ...rsion efficiency It has five protection functions which include input under voltage protection input over voltage protection overload protection over temperature protection and output short circuit protection These five functions can protect the electrical equipment and the circuit of the car Please read instructions carefully before use Features and cable diagram 1 Fan 5 Fault light red light 2 D...
Страница 3: ...e red cable connect with terminal of the battery and the clip on the black connect with the terminal Do not reverse or it will destroy the power inverter d Turn on the power inverter the green light will on Insert the plug of the electric equipment into the AC socket of the inverter 3 Scope of application a Electrical equipment can be used Office equipment Computers printers facsimile printers sca...
Страница 4: ...g and after a short period where it has cooled down the inverter will restart working automatically 6 To save energy the fan will not work unless a The fan will work when the load exceeds 30 of the related power of the inverter b When the inside temperature of the inverter exceed 60 degree the fan will work 7 Extension cable use a We do not recommend the use of any extension cables between the inv...
Страница 5: ...Alarm No AC output When the voltage of the battery returns to the related range the inverter will start working green light will go on red light will go off Input over voltage protection Green on Red on No alarm No AC output When the voltage of the battery returns to the related range the inverter will start working green light will go on red light will go off Over load protection Green on Red on ...
Страница 6: ...1600W 2000W 3000W Output wave Modified sine wave Efficiency 80 No load current 0 35A 0 45A 0 45A Input under voltage alarm DC 10 2 10 8V Input under voltage shut down DC 9 2 9 8V Input over voltage shut down DC 15 16V Overload shut down 850W 1040W 1150W 1300W 1700W 1950W Fuse 25A 4 30A 4 30A 6 The best working temperature 5 35 Cooling method Fan Accessories Cigar cable Battery clip cable Technical...