Installation and Configuration
Ndrive QL Hardware Manual
2.2. Electrical Installation
The Ndrive QL has one AC input power connector. For a complete list of electrical specifications, refer to
Section 1.1. Electrical Specifications
.
2.2.1. Power Input (TB101)
AC input power to the QL is applied to the Input Power (TB101) connector.
The connection requires a minimum of 100 VAC input to operate properly. The AC1 and AC2 inputs are
internally fused.
Figure 2-1
shows the required connections to the control power input.
POWER INPUT
AC1
AC2
TB101
100-240V~
50/60Hz
2A MAX
Figure 2-1:
Power Input Connections
Table 2-1:
Power Supply Wiring (TB101)
Pin
Description
Recommended Wire Size
AC1
100 - 240 VAC Input Range
1.3 mm
2
(#16 AWG)
AC2
100 - 240 VAC Input Range
1.3 mm
2
(#16 AWG)
Protective Ground (Required for Safety)
1.3 mm
2
(#16 AWG)
Type
Aerotech P/N
Phoenix P/N
Screw Torque
Value: Nm
Wire Size:
AWG [mm
2
]
3-Pin Terminal Block
ECK00213
1754465
0.5 - 0.6
12-30 [3.3 - 0.516]
20
Chapter 2
www.aerotech.com
All manuals and user guides at all-guides.com