4.3. Motor Mounting
DANGER
:
Electrical Shock Hazard!
l
Do not connect or disconnect electrical components, wires, and cables while this
product is connected to a power source.
l
Before you do maintenance to the equipment, disconnect the electrical power.
l
Uncouple or otherwise prevent motion of motor-coupled machinery when you do ser-
vice to the equipment.
Table 4-1:
Hardware Requirements
Motor
Screw Size
Shaft Coupling Screw
Size
Coupling Screw Bit Size
Coupling Screw Torque
M4
M2.5
2 mm Hex
7 in·lbs
IMPORTANT
: Use Loctite 242 or Loctite 248 on the motor and coupling adapter
hardware (
). Loctite products are printed with an expiration date. Before use,
be sure that the expiration date is legible and the product has not expired.
If your stage is used in a vacuum or cleanroom environment, contact Aerotech.
Figure 4-3:
Motor Mounting Overview
4.3. Motor Mounting
ECO165SL Hardware Manual
48
www.aerotech.com
Содержание ECO165SL Series
Страница 1: ...Revision 2 01 ECO165SL Series Mechanical Bearing Ball Screw Stage HARDWARE MANUAL...
Страница 14: ...This page intentionally left blank Handling and Storage ECO165SL Hardware Manual 14 www aerotech com...
Страница 22: ...Figure 2 2 Tabletop Accessory Dimensions TT3 Option 2 1 Dimensions ECO165SL Hardware Manual 22 www aerotech com...
Страница 23: ...Figure 2 3 Z Axis Bracket Dimensions ECO165SL Hardware Manual 2 1 Dimensions www aerotech com 23...
Страница 46: ...Figure 4 1 Hardcover Screw Removal 4 2 Cleaning and Lubrication ECO165SL Hardware Manual 46 www aerotech com...
Страница 47: ...Figure 4 2 Hardcover Removal ECO165SL Hardware Manual 4 2 Cleaning and Lubrication www aerotech com 47...
Страница 58: ...This page intentionally left blank Appendix B Revision History ECO165SL Hardware Manual 58 www aerotech com...