![Aerotech BT 400-46 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/aerotech/bt-400-46/bt-400-46_installation-and-operation-maintenance_2863066012.webp)
AEROTECH HERMAN NELSON INTERNATIONAL INC.
100 Eagle Drive, Winnipeg, Manitoba Canada R2R 1V5
Phone: 204-633-1999 (24 Hours) Fax: 204-694-1612 Email:
Check Out Our Web site
www.hermannelson.com
New Items Added Weekly
12.18.07 REVISION 1.02
Section 3
• Preparation for Use & Storage
• • • • • • • • • • • • • • • •
3.1 General
3.2 Scope
3.3
The heater unit is shipped as a pre-tested, completely assembled unit. There are, however,
certain steps which shall be taken prior to putting the unit into operation or storage.
3.4 Preparation for use
3.5
To prepare the heater for use proceed as follows:
(a) Remove all crafting, blocking, and protective material from heater.
! CAUTION !
Do not use forklift to move heater.
This could cause damage to unit.
(b) Check action of parking brake and set brake to prevent heater from rolling.
(c) Inspect unit for any damaged gauges, meters, valves, loose connections or
mountings, loose or missing hardware, frayed insulation on wiring, or any
other damage.
(d) Check drive V-belt for proper tension and condition.
(e) Using a hydrometer, check each battery cell for a specific gravity of 1.250
or higher. Ensure electrolyte level is 1/4 inch to 1/2 inch above the top of the
battery plates.
! WARNING !
Use protective clothing, face shield, rubber gloves and apron when servicing battery.
! WARNING !
Do not smoke or use an open flame in heater vicinity while servicing the fuel tank.
Failure to comply may result in serious injury or death.
(g) Remove fuel tank filler cap and fill tank to capacity with recommended fuel.
Replace filler cap.
(h) Check engine oil level.
(i) Ensure tire pressure is 20 psi max.
6