BA10/20/30 Series User’s Manual
Cable Drawings
Version 1.6
Aerotech, Inc.
C-1
APPENDIX C:
CABLE DRAWINGS
In This Section:
•
Description ................................................ C-1
Description
The following section provides the user with 2 reference drawings for connecting
Aerotech cables to the BA amplifiers.
Figure C-1.
BA Feedback Cable (PFC)
BLU / BLK
SIGNALS CONNECT TO CONTROLLER OR TO
BA10/20 SERVO AMPLIFIER AS SYSTEM
CONFIGURATION DICTATES.
BA Series
Servo Amp
TYPICAL INTERCONNECT
: SYSTEM
CONFIGURATION
DETERMINES WHETHER
APPLICABLE SIGNAL
CONNECTS TO BA10/20 OR
NOT.
CONNECTIONS TO P1-8
(COS-N) AND P1-19 (SIN-N)
ARE NOT APPLICABLE ON
REV. - OR REV A AMPLIFIER
PC BUS. (690D1499)
NOTE
CABLE IS SIGNAL
BUNDLE OF
682A1023 (ECX413)
BASE
COLOR
CONSOLIDATED
#5720 (20 COND. #24). ECX___
OR
#5738 (20 COND. #22). ECX579
STRIPE
STRAIGHT PLUG MS3106A - 20 (MCM454)
INSERT MS20 - 295 (MCM464)
CLAMP AM3057 - 12 (MCM457)
BUSHING AN3055 - 22 - 12 (MCM493)
S
T
E
F
B
A
D
C
G
H
K
M
P
J
BRAKE +
BRAKE -
MARKER
MARKER-N
COS-N
COS
SIN-N
SIN
ENC COM
ENC 5V
HALL EFFECT A
HALL EFFECT B
HALL EFFECT C
CW LMT-N
CCW LMT-N
HOME LMT-N
LMT COM
LMT 5V
#22 G/YEL
SPLICE
P1
6
5
19
18
14
2
4
16
17
15
20
1
1 FT
#24 GRY
#24 VIO
#24 W/GRY
#24 W/BRN
#24 W/ORN
#24 W/RED
#24 W/GRN
#24 W/YEL
#22 W/BLK
#22 YEL
#24 R/GRN
#24 R/YEL
#24 W/BLK/BRN
#24 W/BLU
#24 W/VIO
#24 R/BLK
#22 BRN
#22 PINK
#24 TAN
#24 W/BLK/RED
WHT / BLK
GRN / WHT
ORN / BLK
ORN / RED
WHT / RED
BLK / RED
BLU / RED
GRN / BLK
RED / BLK
RED / WHT
BLK / WHT
BLU / WHT
WHT
BLK
ORN
GRN
RED
BLU
RED / GRN
3
CONNECTOR TYPE
9 PIN FEMALE “D”
DE9S, ECK340
+ BACKSHELL, 3M# 3357-9209. ECK158
OR
CINCH# DE24657, EIZ294
#24 W/BLU
#24 W/VIO
#24 R/BLK
#22 BRN
#22 PINK
5
4
2
1
1 1/4“
STRIP BACK INSULATION 3/16“ FROM
THIS END, COVER ALL SOLDER
CONNECTIONS WITH HEATSHRINK.
LOOP LIMIT CONNECTOR WIRES (PINK,
BRN, WHT/VIO, WHT/BLU, RED/BLK) BACK
OUT OF MS CONNECTOR THROUGH
HEATSHIRNK.
LEAVE LIMIT CONNECTOR WIRES PROTRUDE OUT OF
JACKET 7 1/2“ FOR MAKING CONNECTION TO LIMIT
CONNECTOR. ORIGINAL LENGTH OF CABLE MUST BE
15’ 6 1/2”.
LIMIT CONNECTOR
HEATSHRINK LIMIT CONNECTOR WIRES (PINK, BRN,
WHT/VIO, WHT/BLU, RED/BLK). THIS HEATSHRINK
SHOULD TUCK UNDER THE SHRINK THAT IS USED TO
THICKEN OVERALL CABLE.
USE GROMMET (EIZ131) TO
BUILD UP THICKNESS SO THAT
CLAMP GRIPS CABLE.
14 FT
OR
A.R.
STRIP BACK INSULATION
3/8“ AND TIN WIRES.
630C1582-1
REV B
3C1582B1.DWG
Содержание BA10 SERIES
Страница 4: ...Table of Contents BA10 20 30 Series User s Manual iv Aerotech Inc Version 1 6...
Страница 6: ...List of Figures BA10 20 30 Series User s Manual vi Aerotech Inc Version 1 6...
Страница 8: ...List of Tables BA10 20 30 Series User s Manual viii Aerotech Inc Version 1 6...
Страница 10: ...Regulatory Information BA10 20 30 Series User s Manual x Aerotech Inc Version 1 6...
Страница 22: ...Introduction BA10 20 30 Series User s Manual 1 12 Aerotech Inc Version 1 6...
Страница 48: ...Technical Details BA10 20 30 Series User s Manual 3 8 Aerotech Inc Version 1 6...
Страница 50: ...Troubleshooting BA10 20 30 Series User s Manual 4 2 Aerotech Inc Version 1 6...
Страница 52: ...Glossary of Terms BA10 20 30 Series User s Manual A 2 Aerotech Inc Version 1 6...
Страница 60: ...Revision History BA10 20 30 Series User s Manual R 2 Aerotech Inc Version 1 6...
Страница 62: ......