Installation and Configuration
Npaq® Hardware Manual
2.10.2. Analog Inputs (J10)
To interface to a single-ended (non-differential) voltage source, connect the signal common of the source to
the negative input and the analog source signal to the positive input. A floating signal source should be
referenced to the analog common as shown in
.
Table 2-43:
Differential Analog Input 1 Specifications (J10)
Specification
Value
(AI+) - (AI-)
+10 V to -10 V
(1)
Resolution (bits)
16 bits
Resolution (volts)
305 µV
1. Signals outside of this range may damage the input
Table 2-44:
Analog Input Pins on the Analog I/O Connector (J10)
Pin #
Description
In/Out/Bi
1
Analog Input 0+
Input
2
Analog Input 1+
Input
3
Analog Input 2+
Input
4
Analog Input 3+
Input
7
Analog Ground
N/A
8
Analog Ground
N/A
9
Analog Input 0-
Input
10
Analog Input 1-
Input
11
Analog Input 2-
Input
12
Analog Input 3-
Input
15
Analog Ground
N/A
Figure 2-41:
Analog Inputs (J10)
www.aerotech.com
Chapter 2
77
Содержание A3200 Series
Страница 1: ...Revision 3 08 00 Npaq Hardware Manual...
Страница 14: ...Npaq Hardware Manual Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Страница 25: ...Introduction Npaq Hardware Manual Figure 1 3 Dimensions www aerotech com Chapter 1 25...
Страница 28: ...Npaq Hardware Manual Introduction 28 Chapter 1 www aerotech com This page intentionally left blank...
Страница 96: ...Npaq Hardware Manual Options Figure 3 3 ESTOP2 Option Category 3 PL d 96 Chapter 3 www aerotech com...
Страница 97: ...Options Npaq Hardware Manual Figure 3 4 ESTOP3 Option Category 3 PL d www aerotech com Chapter 3 97...
Страница 122: ...Npaq Hardware Manual Revision History 122 Appendix B www aerotech com This page intentionally left blank...
Страница 128: ...Npaq Hardware Manual Avertissements 128 Appendix C www aerotech com This page intentionally left blank...