background image

CHT-100 Cylinder Head Temperature Indicator 

Page 6 of 11

 

 

Aerospace Logic Inc. 

3150 Ridgeway Drive, Unit #43, Mississauga, Ontario, L5L 5R5, CANADA 

Tel. (905) 569-3887 | Fax. (416) 352-5854 | Email. [email protected] 

www.aerospacelogic.com 

CHT-100 Operations & Installation Manual – Ver. 1.9 – June 5, 2003

 

 

4. SETUP

 

 
Once installed your instrument will require setup to match the specific engine 
parameters as well the user defined preferences. 
 
Instrument setup is only required when a parameter or display configuration is to 
be changed.  With proper planning you should only have to perform this function 
once in the life of the instrument. All information is stored in the instruments 
lifetime memory, which will be retained without battery power for up to 100 years. 
 
To enter 

SETUP

 mode turn off all power to the instrument. Next press and 

HOLD

 

the 

A M S

 switch in the 

S

 position and turn on the power to the instrument. Hold 

the switch in this position until 

SEt-

 is displayed. At this point release the switch. 

 

NOTE: When in the setup mode the display bar will remain blank. The CYL 
digit and the four digit display shows the parameter value and type as per 
the enclosed instructions.
 

 
In order to set the manufacturer specified limits for your engine you will require 
the manufacturer specified high and low limits. Please refer to your engine 
operator’s manual for this information. Most engines will operate between 350ºF 
and 435ºF. 
 
 

CyLS

 (Cylinder Count Selection) 

 
For a 6 cylinder instrument, moving the 

A M S

 switch to the 

A

 position and back 

to the 

M

 position will allow selection between 4 and 6 cylinder operation. 

 
For a 4 cylinder instrument, no choice of cylinder count is available.  Simply 
move the 

A M S

 switch once to the 

S

 position and release. The 4 cylinder 

configuration will now be saved and the display will move to the next parameter. 
 
 

Int

 (Intensity Source Selection) 

 
Moving the 

A M S

 switch to the 

A

 position and back to the 

M

 position will allow 

selection between 

I

 (internal intensity control) or 

E

 (external intensity control). 

 
Select the appropriate intensity source and move the 

A M S

 switch once to the 

S

 

position and release. The intensity source will now be saved and the display will 
move to the next parameter. 
 
 
 
 
 

Содержание CHT-100

Страница 1: ...0 Cylinder Head Temperature Indicator This instrument is a complex precision instrument manufactured to exceed Airborne Equipment Standards DO 160D DO 178B and TSO C43c standards In order for your ins...

Страница 2: ...o ensure that it is functioning correctly In turn the main processor validates the independent monitoring processor Any failure detected in either processor and your instrument display will be shut do...

Страница 3: ...sure proper operation The instrument has been software calibrated and never needs recalibration provided no wiring modifications are made at installation time Now connect the supply and dimmer wiring...

Страница 4: ...r 4 RED Cylinder 2 GREEN Cylinder 5 WHITE Cylinder 3 YELLOW Cylinder 6 If you have purchased a complete instrument and probe kit appropriate connectors for interconnection of the signal wires and prob...

Страница 5: ...Page 5 of 11 Aerospace Logic Inc 3150 Ridgeway Drive Unit 43 Mississauga Ontario L5L 5R5 CANADA Tel 905 569 3887 Fax 416 352 5854 Email sales aerospacelogic com www aerospacelogic com CHT 100 Operati...

Страница 6: ...n the setup mode the display bar will remain blank The CYL digit and the four digit display shows the parameter value and type as per the enclosed instructions In order to set the manufacturer specifi...

Страница 7: ...tch once to the S position and release The low limit will now be saved and applied to all cylinders The display will move to the next parameter H High Temperature Limit Set The high temperature limit...

Страница 8: ...isplay the STEP message for approximately five seconds before starting the step process Once started it will step through all cylinders When the last is reached it will revert back to the first 1 Disp...

Страница 9: ...his mode of operation is the single most important feature of this instrument and should be used for all leaning and cooling function If the instrument is switched from the automatic mode back to the...

Страница 10: ...mocouple Signal Wire Junction Where possible plan the installation such that the junction between the thermocouple and signal wire takes place on the cockpit side of the firewall If this is not possib...

Страница 11: ...sation for thermocouple sensor linearity Minimum 256 times measurement validation before display Operating Temperature 15C to 55C 5F to 131F Power Consumption 370mA Max daytime operation 50mA Min nigh...

Отзывы: