Maintenance: 

 

The mist collector can operate for long periods without maintenance.  The maintenance period will depend on the 
type of oil & solids/chips in air stream.  Some soluble oil & synthetic concentrates will congeal requiring the 
mechanical separator elements and agglomerator filter media to be manually cleaned/washed.  The air flow will 
reduce if this happens. 

 

Inspect the unit after 3 months, 6 months & 1 year to establish the maintenance interval.  If there is no fouling, the 
mist separator can run indefinitely without maintenance.  It is recommended that the 2

nd

 stage agglomerator filter 

media be replaced every 10 years. 
 

 

HEPA filter replacement: 
Replace when magnehelic pressure gauge 
reaches 3” wg 
 
Note: 
If 2

nd

 stage filter is plugged, no air flow will be go 

to 3

rd

 stage filter and pressure reading will be 

low.

 

 

 

 

 

 

 

Содержание ROX-400

Страница 1: ...Oil Mist Eliminator ROX 400 600 800 1100 2000 Installation Service Manual www aeroex com AEROEX Technologies Inc 17 Hamilton Rd Barrie ON Canada L4N 8Y6 Tel 705 734 0199 Fax 705 734 1013 705 734 0199...

Страница 2: ...e can be used Do not locate suction intake on machining applications in direct line of the cutting spray A chip strainer mounted in the machine CNC enclosure is recommended Connect the 2 oil drain lin...

Страница 3: ...ter media to be manually cleaned washed The air flow will reduce if this happens Inspect the unit after 3 months 6 months 1 year to establish the maintenance interval If there is no fouling the mist s...

Страница 4: ...t Insert 3 8 bolt and jack lid up to open Remove the bolts on impeller inlet plate and remove Remove nut on pressure plate and remove Remove 1st stage mechanical separation elements They can be disass...

Страница 5: ...eroex com orderdesk aeroex com 5 On models prior to Jan 2013 Replace bottom foam gasket each time HEPA filter is changed Check oil drain line clean if necessary To remove to remove 3rd stage filter HE...

Страница 6: ...y or high solids coolant applications Use on oil applications 600AF 2010 1 4 a b 2nd stage agglomerator filter ring ROX 400 600 filter ring coolant ROX 400 600 filter ring oil 600FR 2204 600FR 2206 1...

Страница 7: ...solids coolant applications Use on oil applications 1100AF 2010 1 4 a b 2nd stage agglomerator filter ring ROX 800 1100 filter ring coolant ROX 800 1100 filter ring oil 1100FR 2204 1100FR 2206 1 1 5...

Страница 8: ...plications Use on oil applications 2000AF 2010 1 5 a b 2nd stage agglomerator filter ring ROX 2000 filter ring coolant ROX 2000 filter ring oil 2000FR 2204 2000FR 2206 1 1 Pressure Plate for Filter Ri...

Отзывы: