Rev 7-02/19
www.aeroex.com
3
Maintenance:
The mist collector can operate for long periods without maintenance. The maintenance period will depend on the
type of oil & solids/chips in air stream. Some soluble oil & synthetic concentrates will congeal requiring the
mechanical separator elements and agglomerator filter media to be manually cleaned/washed. The air flow will
reduce if this happens.
Inspect the unit after 3 months, 6 months & 1 year to establish the maintenance interval. If there is no fouling, the
mist separator can run indefinitely without maintenance. It is recommended that the 2
nd
stage agglomerator filter
media be replaced every 10 years.
HEPA filter replacement:
Replace when magnehelic pressure gauge
reaches 3” wg
Note:
If 2
nd
stage filter is plugged, no air flow will be go
to 3
rd
stage filter and pressure reading will be
low.