background image

D E V I C E   S E T U P

2 0

C O N N E C T I N G   D I R E C T L Y   T O   A   L A N   P O R T

By default, the ConnexNet is set to obtain its IP address automatically using DHCP.  Typically most PC’s are also 
configured to obtain their IP address from a DHCP server (i.e. switch, router, hub, etc).  If you want to connect the 
ConnexNet directly to the LAN on your PC, you will need to configure both devices with Static IP addresses.

A s s i g n i n g   C o n n e x N e t   a   S t a t i c   I P

1

Connect the ConnexNet device to your network Router, hub, switch, etc.

2

Open the Aerocomm Configuration utility.

3

Go to the PC settings page and select Product Type as “Connex4490.”

4

Change Port Type to “TCP/IP Port.”

5

Press the “Find Ports” button and wait for the software to find the device.

6

Once a device has been discovered, select it from the Port selection dropdown.

7

Type “2101” in the Port field.  This is the default TCP port used to connect to the ConnexNet.

8

Press the “Connect” button to open the selected Port.  The Port Status should now change to 
“Connected.”

9

Press the “Configure” button just below the Port field.  This will bring up a screen which allows 
you to change the IP settings and enable/disable DHCP.  Note: Check with your IT professional 
before making changes to the network configuration of the device.

10

Click on disable DHCP and select the button next to “Use these settings.”

11

Configure the IP address, subnet mask, and default gateway.  You will need to ensure that the 
subnet mask matches the mask used on your PC LAN port.  Note: Check with your IT 
professional before making changes to the network configuration of the device.

12

After making the necessary changes to the configuration, press the “Save Settings” button to 
save the new changes to the ConnexNet device.

A s s i g n i n g   y o u r   P C   L A N   a   S t a t i c   I P

1

Click Start -> Control Panel -> Network Connections.

2

Right click “Local Area Connection” and select “Properties” from the list.

3

Under Local Area Connection Properties, scroll down to “TCP/IP Internet Protocol” in the box 
titled “this connection uses the following items” and press the “Properties” button.

4

Select the bullet next to “Use these settings.”

5

Configure the IP address, subnet mask, and default gateway.  You will need to ensure that the 
subnet mask matches the mask used on your ConnexNet device.  Note: Check with your IT 
professional before making changes to the network configuration of the device.

6

Click “OK” to exit the “Properties” menu.

Содержание CN4490

Страница 1: ...VERSION 1 0...

Страница 2: ...Technical Support Phone 800 492 2320 E mail support aerocomm com Web www aerocomm com support Sales Phone 800 492 2320 E mail sales aerocomm com Web www aerocomm com...

Страница 3: ...mental requirements such as military medical life support or life sustaining equipment are specifically not recommended without additional testing for such application Limited Warranty Disclaimer Limi...

Страница 4: ...DOC U M E N T I NF O R M A T I O N 1 8 0 0 4 9 2 2 3 2 0 w w w a e r o c o m m c o m Revision Description Version 1 0 12 27 07 Initial release version...

Страница 5: ...10 Load Save to File Buttons 10 Port 1 Port 2 Buttons 11 Hex Decimal Button 11 Terminal Chat Page 12 Send Button 12 Hexadecimal ASCII Display 12 Range Test Page 13 Test Selection 13 Transmit Packet S...

Страница 6: ...CONNE XNE T FE ATURES Easy to implement manage and maintain Durable industrial grade enclosure Programmable Network Parameters Support for TCP UDP Telnet PPP connections Fixed 76 8 kbps RF data stream...

Страница 7: ...USA Canada 915 928 MHz Australia RF Data Rate Raw 76 8 kbps RF Technology Frequency Hopping Spread Spectrum FHSS Output Power EIRP 3dBi gain antenna 1000 mW Supply Voltage 7 25 VDC Current Draw mA TB...

Страница 8: ...ng power up or reset indicating successful startup T a bl e 3 S t at us L E D d es c ri pt i o n s LED Color Description Power Green On indicates that the unit is powered up Link Red On indicates that...

Страница 9: ...ernet PoE AUT O MD I MD IX INTER FACE The Auto MDI MDIX feature automatically configures the system hardware connections for proper operation eliminating the need to switch between standard and crosso...

Страница 10: ...e folder on the Aerocomm Tools Literature CD and install the development kit software To install the software run Setup exe and follow the installation prompts During the installation the software wil...

Страница 11: ...are is run it will prompt you to select a product Select the correct product in the Product pull down menu Doing this will automatically select the default baud rate for that particular transceiver If...

Страница 12: ...i o n s These are additional options that can be enabled S A V E S E T T I N G S O N E X I T When enabled all changes made to the Settings page will be automatically loaded the next time the software...

Страница 13: ...he text appears gray the current state will not be shown The text shown in the bottom status bar gives a simplified status of the current pending software process The software has no pending process w...

Страница 14: ...page Radio Interface Radio RF Radio Features Radio Other and Info Center The fields displayed in these sections vary depending on the Product Mode The Info Center provides a quick description of each...

Страница 15: ...ll be updated with the default settings for the selected product This feature is only available on the GUI Page and will not work when using the EEPROM Editor View P a i r i n g B u t t o n The pairin...

Страница 16: ...s depressed the Write Radio and Read Radio buttons communicate through Port 1 When Port 2 is depressed the Write Radio and Read Radio buttons communicate through Port 2 H e x D e c i m a l B u t t o n...

Страница 17: ...it is appended to the appropriate Port window An example of the Terminal Chat page is shown below S e n d B u t t o n This button sends the data in the textbox out the selected port s The current use...

Страница 18: ...selected There are three typical hardware setups 1 One radio is plugged into a serial or USB port on a PC The second radio is plugged into a separate power supply with a loopback adapter connected 2 O...

Страница 19: ...o select how the received packets will be displayed Received packets can either be displayed in ASCII or Hexadecimal format marked with a time stamp and show only when an error has occurred Ta b l e 5...

Страница 20: ...scovered select it from the Port selection dropdown 7 Type 2101 in the Port field This is the default TCP port used to connect to the ConnexNet 8 Press the Connect button to open the selected Port The...

Страница 21: ...acy systems to a network To connect to the ConnexNet the Host simply needs to install the Virtual COM Port driver and then connect to the device using the COM port specified during setup Before you ca...

Страница 22: ...17 DEVICE SETU P www aerocomm com 7 The Choose Destination Location screen will appear Accept the default location 8 The Setup Status screen appears while files are being copied...

Страница 23: ...M port If a User Name Password are selected the credentials will be stored in the Windows registry When any application opens a mapped COM port the details from the registry are used to transparently...

Страница 24: ...Select Raw mode set Port No to 2101 12 After setup is complete press the Done button to finish the installation 13 A completion screen will appear You will be prompted to reboot the computer Select Y...

Страница 25: ...to change the IP settings and enable disable DHCP Note Check with your IT professional before making changes to the network configuration of the device 10 Click on disable DHCP and select the button...

Страница 26: ...covery Manager wait for your device to be discovered 4 Write down the value of the DHCP IP Address 5 Double click on the discovered device to bring up the Edit Attributes dialog E N G I N E E R S T I...

Страница 27: ...fault setting with the IP address shown in the DHCP IP Address field This will be our static IP for the time being and is set to simplify configuration 7 After the changes have been made press the Set...

Страница 28: ...23 DEVICE SETU P www aerocomm com 9 Select TCP IP from the Connect using drop down Type in the IP address you noted from the Auto Discovery Manager Set the port to 23 Press OK to continue...

Страница 29: ...D E V I C E S E T U P 24 10 When prompted login to the device Login admin Password admin...

Страница 30: ...t for an OK response 15 At the prompt type the following command set bridge enable 16 Wait for an OK response 17 At the prompt type the following command set bridge ipmodule ip address 10 16 202 81 No...

Страница 31: ...D E V I C E S E T U P 26 23 At the prompt type the following command save 24 Repeat for second and additional radios...

Страница 32: ...you will not be able to access the device using a TCP socket with the default port of 2101 In order to re gain access to the serial to ethernet functionality you will need to disable the bridge featur...

Страница 33: ...D E V I C E S E T U P 28 3 When prompted login to the device Login admin Password admin...

Страница 34: ...ration 5 Check to make sure that the device reports that bridge is enabled 6 Wait for an OK response 7 At the prompt type the following command set bridge disable 8 The device should respond by statin...

Страница 35: ...l correspondence with Technical Support company name phone number product part number a good description of the problem or question and the EEPROM files for both radios To save the EEPROM files read t...

Отзывы: