5.10    FILTER CLEAN REMINDER SETTING

Filter Clean Reminder Function

: Unit will remember its own operating time. When the setting time is up, this function will remind you to clean the filer. A dirty filter will result 

in bad heating and cooling performance, abnormal protection, bacteria gathering, etc.

Turn on Filter Clean Reminder Function

: When unit is on, press “FUNCTION” button and select Filter Clean Reminder. “

” icon will blink. Press “+” or “-” button to adjust 

the cleaning level, of which the range is 00, 10-39. Press “ENTER” to turn on this function.

Turn off Filter Clean Reminder Function

: When unit is on and this function has been turned on, press “FUNCTION” button and select Clean. Then “

” icon will blink. Set 

the cleaning level as 00 and press “ENTER” function to cancel this setting.

When Filter Clean Reminder time is up, “

” icon will light up to remind you to clean the filter. There are two ways to cancel filter clean reminding:

1. 

Press “

” button twice within one second to cancel reminding and it will retime according to the original cleaning level.

2. 

Press “FUNCTION” button to turn to Filter Clean Reminder Function, then press “ENTER” to cancel reminding, and it will retime according to the original cleaning level. The 
clean reminding can be cancel only when you didn’t reset the cleaning level under the setting of Filter Clean Reminder Function.

 

NOTE:

Description on cleaning level

: When setting the Filter Clean Reminder Function, timer zone will display 2 digits, of which the former indicates the pollution degree of oper-

ating place and the latter indicates the operating time of indoor unit. 

There are 4 types of situations:

Pollution level of the environment where 

the indoor unit is installed

Description of Levels

Turn off Clean reminding

Timer zone shows 00

Light Pollution

The former digit shows 1 while the latter one shows 0, which indicates the accumulating operating time is 5500 hours. Each time the 
latter digit increases 1, the operating time increases 500 hours. When it reaches 9, it means the operating time is 10000 hours.

Medium Pollution

The former digit shows 2 while the latter one shows 0, which indicates the accumulating operating time is 1400 hours. Each time the 
latter digit increases 1, the operating time increases 400 hours. When it reaches 9, it means the operating time is 5000 hours.

Heavy Pollution

The former digit shows 3 while the latter one shows 0, which indicates the accumulating operating time is 100 hours. Each time the 
latter digit increases 1, the operating time increases 100 hours. When it reaches 9, it means the operating time is 1000 hours.

5.11    X-FAN  SETTING

X-FAN function

: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew.

Under Cooling or Dry mode, press “FUNCTION” button to select X-FAN. “

” icon will blink.

Then press “ENTER” button to turn on/off this function.

5.12    I-DEMAND  SETTING

I-DEMAND Function

: The unit will operate in the “

SE

” mode to save energy. I-DEMAND function can be only used under cooling mode.

Under Cooling mode, press “FUNCTION” button to select I-DEMAND. “

” icon will blink.

Then press “ENTER” button to turn on/off this function.

5.13    ABSENT  SETTING

Absence Function

: This is used to maintain indoor temperature so that unit can realize fast heating after it is turned on. This function can only be used under Heating mode.

Under Heating mode, press “FUNCTION” button to select Absence. “

” icon will blink.

Then press “ENTER” button to turn on/off this function.

5.14    SHIELDING  STATUS

Remote Shield Function

: Remote monitor or central controller can disable the relevant functions of wired controller so as to realize the function of remote control.

When the remote monitor or central controller activates Remote Shield on the wired controller, “

” icon will show. If user wants to control through the wired controller, “

” icon will blink to remind that these controls are disabled.

5.15    CHILD LOCK FUNCTION

Child Lock Function

: When unit is turned on normally or turned off, pressing “+” and “-” button together for 5 seconds will turn on Child Lock function. “

” will show on the 

display. Pressing “+” and “-” together again for 5 seconds to turn off this function.
All the other buttons will be disabled when Child Lock function is on.

5.16    INQUIRY OF INDOOR TEMPERATURE WITH ONE BUTTON

In the homepage, hold “ENTER” button for 5 seconds, and the wired controller will display the indoor temperature for 5 seconds.
Within the 5 seconds, it can quit displaying the indoor temperature immediately and be responded to the instructions as usual after pressing any buttons.

5.17    SETBACK  FUNCTION

In unit off status with Setback Function activated, the unit will operate in heating mode automatically when indoor temperature is lower than temperature lower limit for 
Setback Function and operate in cooling mode automatically when indoor temperature is higher than temperature upper limit for Setback Function, so as to keep indoor 
temperature within the temperature upper and lower limit range for Setback Function.
In unit off status, if the air conditioner is operating in cooling or heating mode of Setback Function, the wired controller will display the status code “A9”.

Содержание WRC50

Страница 1: ...2 3 0 2 5 3 8 5 7 4 6 _ 0 0 T r a n s l a t i o n o f O r i g i n a l i n s t r u c t i o n s User manual w w w a e r m e c c o m WRC50 WIRED CONTROLLER ...

Страница 2: ... any notice thereof Thank you again Aermec S p A COMPANYCERTIFICATIONS SAFETYCERTIFICATIONS This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the envi ronment or human health from uncontrolled disposal of Waste Electrical and Electronic Equipment WEEE please return the device using appropriate collection system...

Страница 3: ... p 13 Mode Setting p 13 Temperature Setting p 14 Fan Setting p 14 Timer Setting p 14 Set delivery fin swing p 16 Quiet Function Setting p 16 Sleep Setting p 16 Energy Saving Function Setting p 16 Filter clean reminder setting p 18 X fan Setting p 18 I Demand Setting p 18 Absent Setting p 18 Shielding status p 18 Child Lock function p 18 Inquiry of Indoor Temperature with one button p 18 Setback Fu...

Страница 4: ...nternal parts 3 Do not modify or repair the air conditioner by yourself 4 Do not move or re install the device by yourself 5 Do not use flammable materials near the device To clean the device do not use organic solvents such as paint thinners Possible result damages electric shock or fire accidents WARNINGS FOR THE INSTALLER This device cannot be used on its own Also refer to the user manuals of t...

Страница 5: ... the wireless remote controller with wet hands 5 This product is applicable to LPG unit whose outdoor unit and indoor unit communicate with each other by live line and neutral line 6 When two wired controllers control one or more indoor unit s the address of wired controller should be different 3 DISPLAY Fig 3 1 Outside View of the Wired Controller 2 3 D 3 1 LCD OF THE WIRED CONTROLLER Fig 3 2 LCD...

Страница 6: ...ion 14 FUNCTION NOT AVAILABLE 15 Remind to clean the filter 16 X FAN function 17 FUNCTION NOT AVAILABLE 18 Save status of indoor unit 19 FUNCTION NOT AVAILABLE 20 I DEMAND function Indoor unit optional function 21 Quiet status including Quiet and Auto Quiet two status 22 Night time comfort function 23 Left Right Swing Setting 24 Up Down Swing Setting 25 3 D FUNCTION NOT AVAILABLE 26 FUNCTION NOT A...

Страница 7: ...munication wire Fig 4 3 Length of communication wire L L01 L02 L1 L2 L n 1 n 16 1 2 3 n L1 L2 L n 1 MASTER SLAVE L02 L01 Indoor unit Indoor unit Indoor unit Indoor unit Wired panel Cable type Max lenght Size Note Standard 2 pole cable with PVC sheath 60227 IEC 52 60227 IEC 53 L 250 m From 2 x 0 75 to 2 x 1 25 mm2 1 Totallengthofcommunicationlinecan texceed250m 2 ThecordshallbeCircularcord thecores...

Страница 8: ...erature object or the place is likely to be spattered with water 4 It is not allowed to install the wired controller outdoor 4 1 3 Requirements for wired connection Network connecting methods between wired controller and indoor unit are as below Fig 4 4 one wired controller controls one indoor unit 1 D1 D2 or N 1 2 3 2 H1 H2 1 2 Indoor unit Outdoor unit Fig 4 5 two wired controllers control one in...

Страница 9: ... can be adopted for the wired controller connecting LPG unit 2 When one or two wired controller s control s multiple indoor units simultaneously the wired controller can connect to any one indoor unit The total quantity of indoor unit controlled by wired controller can t exceed 16 sets and the connected indoor unit must be within the same indoor unit s network Wire controller must set quantity of ...

Страница 10: ...ion hole in the wall and thread the wire through the hole in the back of soleplate of wired controller 3 Stick the soleplate of wired controller on the wall and use Self tapping Screw ST3 9 25 MA or screw M4 25 to fix the soleplate with the installation hole of wall 4 Connect the 2 core twisted pair to wiring terminal H1 and H2 and then tighten the screw 5 Arrange the wires in the back of panel an...

Страница 11: ...door unit Temperature zone displays current indoor unit project number Timer zone displays outdoor ambient temperature C08 View Filter Clean Reminder time 4 416 days Timer zone displays Filter Clean Reminder time C09 Display the address of the wired panel 01 02 Timer zone displays the address of wired controller C11 View the indoor unit quantity 01 16 This parameter indicates in the timer zone the...

Страница 12: ...0 C 01 F 00 This parameter specifies which unit of measure is used to display temperatures P30 Set static pressure of indoor fan motor 01 09 static pressure level of indoor fan motor 05 P42 Setting the serial address of the indoor unit 1 36 for CC2 1 255 for BMS Setting indoor unit address when it is connected to a CC2 centralized controller or a third party management system BMS P46 Clear Filter ...

Страница 13: ...De Humidification D Ventilation E Heating F FUNCTION NOT AVAILABLE G FUNCTION NOT AVAILABLE H FUNCTION NOT AVAILABLE 3 D A B C D E F G H Or A Auto B Cooling C De Humidification D Ventilation E Heating A B C D E NOTE 1 The available modes are different for different models the wired controller will automatically select mode setting range according to the model of indoor unit 2 Under Auto mode if th...

Страница 14: ...ith two kinds of timer general timer and clock timer General timer is factory defaulted setting Please refer to 4 2 3 Activation of indoor unit operating parameter modification menu p 12 Parameter Setting for the timer setting way 5 5 1 General timer Unit On Off after a desired hour can be set through general timer Set Timer when timer is not set press TIMER button to enter timer setting and HOUR ...

Страница 15: ...n unit On status 1 Unit is on and timer is not set 2 Press TIMER button to set unit On time 3 Press or button to adjust unit On time 4 Press TIMER button to switch to unit Off time setting 5 Press or button to adjust unit Off time 6 Press ENTER button to finish setting 1 2 4 3 5 6 ...

Страница 16: ...button to turn to Quiet function and then press ENTER button to cancel Quiet function NOTE 1 When Quiet function is enabled indoor unit will operate at quiet fan speed Fan speed is lowered so as to reduce the noise of indoor fan motor 2 When Auto Quiet function is enabled indoor unit will change fan speed automatically according to room temperature After room temperature reaches a set point unit w...

Страница 17: ...a sound and then unit will en ter into Energy Saving setting mode icon is blinking Mode icon is on Press MODE button to switch to Heating mode Press or button to adjust the temperature limit for Save function Press ENTER button to start up Save function After starting up save function it will display icon for all modes under on and off status Cancel Energy Saving function When the unit is off pres...

Страница 18: ...reases 1 the operating time increases 100 hours When it reaches 9 it means the operating time is 1000 hours 5 11 X FAN SETTING X FAN function After the unit is turned off the water in evaporator of indoor unit will be automatically evaporated to avoid mildew Under Cooling or Dry mode press FUNCTION button to select X FAN icon will blink Then press ENTER button to turn on off this function 5 12 I D...

Страница 19: ...unication errors remember that different indoor units must have different serial addresses It is not possible to connect more than 36 indoor units to centrilized controller CC2 The MINIMODBUS20 accessory to be purchased separately is mandatory for connecting the units to the CC2 centralized controller 5 19 SET THE INDOOR UNIT ADDRESS BMS To manage the indoor unit with BMS supervision system each i...

Страница 20: ...tection C9 Compressor driver memory chip failure AE Outdoor unit fan motor current detection circuit error EL Emergency stop fire alarm Ac Outdoor unit fan motor starting error oE Outdoor unit error for the specific error refer to the state indicated on the main board of the outdoor unit Aj Outdoor unit fan motor phase displacement protection error Dc Compressor intake temperature probe error UL O...

Страница 21: ...or Q7 Indoor unit DC fan motor card reset error DH Control panel card fault Q8 Indoor unit DC fan motor overcurrent error L4 Control panel power supply fault Q9 Indoor unit DC fan motor power error 6 1 3 Table of status codes Code Description Code Description Fo Refrigerant gas recovery mode H1 Ordinary defrosting state ...

Страница 22: ......

Страница 23: ......

Страница 24: ...m qrcode asp q 19388 http www aermec com qrcode asp q 19387 http www aermec com qrcode asp q 19386 http www aermec com qrcode asp q 19385 http www aermec com qrcode asp q 19384 A e r m e c S p A V i a R o m a 9 9 6 3 7 0 4 0 B e v i l a c q u a V R I t a l i a T e l 3 9 0 4 4 2 6 3 3 1 1 1 F a x 3 9 0 4 4 2 9 3 5 7 7 m a r k e t i n g a e r m e c c o m w w w a e r m e c c o m ...

Отзывы: