5.3    TEMPERATURE  SETTING

Press “+” or “-” button under on status to increase or decrease set temperature by 0.5°C/1°C or 1°F; hold “+” or “-” button to increase or decrease set temperature by 0.5°C/1°C 
or 1°F every 0.3s. Please refer to "4.2.3 Activation of indoor unit operating parameter modification menu p. 12" Parameter Setting for the setting method of the temperature 
setting interval in Celsius.
n Dry mode, when temperature is 16°C or 61°F, continuously press “-” button twice to decrease temperature to 12°C or 54°F (when save function is activated, the temperature 
in Dry mode can’t be adjusted to 12°C or 54°F).
When the control method under Dry mode is humidity control, press “+” or “-” button to adjust the set humidity at 5% intervals.
The humidity setting range is 45%-75%, and the default value is 65%. The humidity control method under Dry mode can only be set for the unit with this function. 
Please refer to "4.2.3 Activation of indoor unit operating parameter modification menu p. 12" Parameter Setting for the setting method.

 

NOTE:

1. 

Only when the wired controller controls LPG indoor units can the setting temperature be adjusted by pressing “+” or “-” under Auto mode.

2. 

When Absence function is activated, the setting temperature cannot be adjusted by pressing “+” or “-”.

5.4    FAN  SETTING

Under On status, pressing “FAN” button can set fan speed circularly as:

AUTO

In unit on status, press “FUNCTION” button to switch to Turbo function with Turbo function icon “TURBO” blinking, and then press “ENTER” button to start or cancel Turbo 
function.

When Turbo function is activated, Turbo function icon “

” will be bright.

 

NOTE:

1. 

Under Dry mode, fan speed is low and can’t be adjusted.

2. 

If indoor unit’s fan speed is set auto, indoor unit will change fan speed automatically according to room temperature in order to make the room temperature more stable 
and comfortable.

5.5    TIMER  SETTING

The wired controller is equipped with two kinds of timer: general timer and clock timer. 
General timer is factory defaulted setting. Please refer to "4.2.3 Activation of indoor unit operating parameter modification menu p. 12" Parameter Setting for the timer 
setting way.

5.5.1    General  timer

Unit On/Off after a desired hour can be set through general timer.

Set Timer

: when timer is not set, press “TIMER” button to enter timer setting and “HOUR” icon is blinking. Press “+” or “-” button to adjust timer time. Press “TIMER” button to 

save the setting and then exit setting.

Cancel Timer

: when timer is set, press “TIMER” button to cancel it.

Timer setting range

: 0.5-24h. Press “+” or “-” button to increase or decrease timer time by 0.5h; hold “+” or “-” button to increase or decrease timer time by 0.5h every 0.3s.

5.5.2    Clock  setting
Clock display

: when the timer setting way is clock timer, timer zone displays system clock in unit On and Off status. The clock can be set at this time.

Clock setting

: long press “TIMER” button for 5s to enter clock setting. Press“+” or “-” button to increase or decrease clock time by 1min; hold “+” or “-” button for 5s to increase 

or decrease clock time by 10min; hold “+” or “-” button for 10s to increase or decrease clock time by 60min.
Press “ENTER” button or “TIMER” button to save the setting and then exit setting.

5.5.3    Clock  timer

Unit On/Off at a certain time can be set through clock timer.

Timer Setting

:

1. 

Press “TIMER” button to enter timer on setting and the “ON” icon is blinking.

2. 

Press “+” or “-” button to adjust unit On time. Press “ENTER” button to finish setting.

3. 

Before pressing “ENTER” button, pressing “TIMER” button can save unit On time and then switch to unit Off time setting with “OFF” icon blinking.

4. 

Press “+” or “-” button to adjust unit Off time. Press “ENTER” button to finish setting.

Cancel Timer

:

Press “TIMER” button to enter timer setting; press “TIMER” button again to switch to the setting of unit ON time or unit Off time; press “ENTER” button to cancel timer.
Press “+” or “-” button to increase or decrease timer time by 1min; hold “+” or “-” button for 5s to increase or decrease timer time by 10min; hold “+” or “-” button for 10s to 
increase or decrease 60min.

Содержание WRC50

Страница 1: ...2 3 0 2 5 3 8 5 7 4 6 _ 0 0 T r a n s l a t i o n o f O r i g i n a l i n s t r u c t i o n s User manual w w w a e r m e c c o m WRC50 WIRED CONTROLLER ...

Страница 2: ... any notice thereof Thank you again Aermec S p A COMPANYCERTIFICATIONS SAFETYCERTIFICATIONS This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the envi ronment or human health from uncontrolled disposal of Waste Electrical and Electronic Equipment WEEE please return the device using appropriate collection system...

Страница 3: ... p 13 Mode Setting p 13 Temperature Setting p 14 Fan Setting p 14 Timer Setting p 14 Set delivery fin swing p 16 Quiet Function Setting p 16 Sleep Setting p 16 Energy Saving Function Setting p 16 Filter clean reminder setting p 18 X fan Setting p 18 I Demand Setting p 18 Absent Setting p 18 Shielding status p 18 Child Lock function p 18 Inquiry of Indoor Temperature with one button p 18 Setback Fu...

Страница 4: ...nternal parts 3 Do not modify or repair the air conditioner by yourself 4 Do not move or re install the device by yourself 5 Do not use flammable materials near the device To clean the device do not use organic solvents such as paint thinners Possible result damages electric shock or fire accidents WARNINGS FOR THE INSTALLER This device cannot be used on its own Also refer to the user manuals of t...

Страница 5: ... the wireless remote controller with wet hands 5 This product is applicable to LPG unit whose outdoor unit and indoor unit communicate with each other by live line and neutral line 6 When two wired controllers control one or more indoor unit s the address of wired controller should be different 3 DISPLAY Fig 3 1 Outside View of the Wired Controller 2 3 D 3 1 LCD OF THE WIRED CONTROLLER Fig 3 2 LCD...

Страница 6: ...ion 14 FUNCTION NOT AVAILABLE 15 Remind to clean the filter 16 X FAN function 17 FUNCTION NOT AVAILABLE 18 Save status of indoor unit 19 FUNCTION NOT AVAILABLE 20 I DEMAND function Indoor unit optional function 21 Quiet status including Quiet and Auto Quiet two status 22 Night time comfort function 23 Left Right Swing Setting 24 Up Down Swing Setting 25 3 D FUNCTION NOT AVAILABLE 26 FUNCTION NOT A...

Страница 7: ...munication wire Fig 4 3 Length of communication wire L L01 L02 L1 L2 L n 1 n 16 1 2 3 n L1 L2 L n 1 MASTER SLAVE L02 L01 Indoor unit Indoor unit Indoor unit Indoor unit Wired panel Cable type Max lenght Size Note Standard 2 pole cable with PVC sheath 60227 IEC 52 60227 IEC 53 L 250 m From 2 x 0 75 to 2 x 1 25 mm2 1 Totallengthofcommunicationlinecan texceed250m 2 ThecordshallbeCircularcord thecores...

Страница 8: ...erature object or the place is likely to be spattered with water 4 It is not allowed to install the wired controller outdoor 4 1 3 Requirements for wired connection Network connecting methods between wired controller and indoor unit are as below Fig 4 4 one wired controller controls one indoor unit 1 D1 D2 or N 1 2 3 2 H1 H2 1 2 Indoor unit Outdoor unit Fig 4 5 two wired controllers control one in...

Страница 9: ... can be adopted for the wired controller connecting LPG unit 2 When one or two wired controller s control s multiple indoor units simultaneously the wired controller can connect to any one indoor unit The total quantity of indoor unit controlled by wired controller can t exceed 16 sets and the connected indoor unit must be within the same indoor unit s network Wire controller must set quantity of ...

Страница 10: ...ion hole in the wall and thread the wire through the hole in the back of soleplate of wired controller 3 Stick the soleplate of wired controller on the wall and use Self tapping Screw ST3 9 25 MA or screw M4 25 to fix the soleplate with the installation hole of wall 4 Connect the 2 core twisted pair to wiring terminal H1 and H2 and then tighten the screw 5 Arrange the wires in the back of panel an...

Страница 11: ...door unit Temperature zone displays current indoor unit project number Timer zone displays outdoor ambient temperature C08 View Filter Clean Reminder time 4 416 days Timer zone displays Filter Clean Reminder time C09 Display the address of the wired panel 01 02 Timer zone displays the address of wired controller C11 View the indoor unit quantity 01 16 This parameter indicates in the timer zone the...

Страница 12: ...0 C 01 F 00 This parameter specifies which unit of measure is used to display temperatures P30 Set static pressure of indoor fan motor 01 09 static pressure level of indoor fan motor 05 P42 Setting the serial address of the indoor unit 1 36 for CC2 1 255 for BMS Setting indoor unit address when it is connected to a CC2 centralized controller or a third party management system BMS P46 Clear Filter ...

Страница 13: ...De Humidification D Ventilation E Heating F FUNCTION NOT AVAILABLE G FUNCTION NOT AVAILABLE H FUNCTION NOT AVAILABLE 3 D A B C D E F G H Or A Auto B Cooling C De Humidification D Ventilation E Heating A B C D E NOTE 1 The available modes are different for different models the wired controller will automatically select mode setting range according to the model of indoor unit 2 Under Auto mode if th...

Страница 14: ...ith two kinds of timer general timer and clock timer General timer is factory defaulted setting Please refer to 4 2 3 Activation of indoor unit operating parameter modification menu p 12 Parameter Setting for the timer setting way 5 5 1 General timer Unit On Off after a desired hour can be set through general timer Set Timer when timer is not set press TIMER button to enter timer setting and HOUR ...

Страница 15: ...n unit On status 1 Unit is on and timer is not set 2 Press TIMER button to set unit On time 3 Press or button to adjust unit On time 4 Press TIMER button to switch to unit Off time setting 5 Press or button to adjust unit Off time 6 Press ENTER button to finish setting 1 2 4 3 5 6 ...

Страница 16: ...button to turn to Quiet function and then press ENTER button to cancel Quiet function NOTE 1 When Quiet function is enabled indoor unit will operate at quiet fan speed Fan speed is lowered so as to reduce the noise of indoor fan motor 2 When Auto Quiet function is enabled indoor unit will change fan speed automatically according to room temperature After room temperature reaches a set point unit w...

Страница 17: ...a sound and then unit will en ter into Energy Saving setting mode icon is blinking Mode icon is on Press MODE button to switch to Heating mode Press or button to adjust the temperature limit for Save function Press ENTER button to start up Save function After starting up save function it will display icon for all modes under on and off status Cancel Energy Saving function When the unit is off pres...

Страница 18: ...reases 1 the operating time increases 100 hours When it reaches 9 it means the operating time is 1000 hours 5 11 X FAN SETTING X FAN function After the unit is turned off the water in evaporator of indoor unit will be automatically evaporated to avoid mildew Under Cooling or Dry mode press FUNCTION button to select X FAN icon will blink Then press ENTER button to turn on off this function 5 12 I D...

Страница 19: ...unication errors remember that different indoor units must have different serial addresses It is not possible to connect more than 36 indoor units to centrilized controller CC2 The MINIMODBUS20 accessory to be purchased separately is mandatory for connecting the units to the CC2 centralized controller 5 19 SET THE INDOOR UNIT ADDRESS BMS To manage the indoor unit with BMS supervision system each i...

Страница 20: ...tection C9 Compressor driver memory chip failure AE Outdoor unit fan motor current detection circuit error EL Emergency stop fire alarm Ac Outdoor unit fan motor starting error oE Outdoor unit error for the specific error refer to the state indicated on the main board of the outdoor unit Aj Outdoor unit fan motor phase displacement protection error Dc Compressor intake temperature probe error UL O...

Страница 21: ...or Q7 Indoor unit DC fan motor card reset error DH Control panel card fault Q8 Indoor unit DC fan motor overcurrent error L4 Control panel power supply fault Q9 Indoor unit DC fan motor power error 6 1 3 Table of status codes Code Description Code Description Fo Refrigerant gas recovery mode H1 Ordinary defrosting state ...

Страница 22: ......

Страница 23: ......

Страница 24: ...m qrcode asp q 19388 http www aermec com qrcode asp q 19387 http www aermec com qrcode asp q 19386 http www aermec com qrcode asp q 19385 http www aermec com qrcode asp q 19384 A e r m e c S p A V i a R o m a 9 9 6 3 7 0 4 0 B e v i l a c q u a V R I t a l i a T e l 3 9 0 4 4 2 6 3 3 1 1 1 F a x 3 9 0 4 4 2 9 3 5 7 7 m a r k e t i n g a e r m e c c o m w w w a e r m e c c o m ...

Отзывы: