THREE-WAY VALVE FOR COIL VCH
ACCESSORIES DATA
BC10
75
37
35
97
215
TECHNICAL DATA
Start input powert
VA
8
Operation input power
VA
3
Water temperature
°C
4 ÷ 100
Operation time
min.
2 ÷ 4
Max. differential pressure
kPa
30
Max. static pressure
kPa
1600
Room temperature
°C
0 ÷ 40
Protection degree
IP 44
Flow direction
Valve activated
AB - A
Valve unoperative
AB - B
Valve connectors [mm]:
AB
A
B
VCH
ø1/2”
ø1/2”