How to modify a parameter in the installer menu:

 

To

 

enter

 

the

 

INSTALLER

 

menu,

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A).Once

 

the

 

key

 

has

 

been

 

pressed

 

the

 

password

 

must

 

be

 

insertedfor

 

access

 

to

 

the

 

various

 

menus.

 

To

 

access

 

the

 

user

 

menu

 

the

 

password is 030

.

 

To

 

modify

 

the

 

value

 

of

 

the

 

password

 

use

 

thearrow

 

keys.

 

Once

 

the

 

correct

 

password

 

has

 

been

 

inserted,

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A).

 

The

 

dis

play

 

shows

 

the

 

index

 

of

 

the

 

INSTALLER

 

parameter

 

and

 

a

 

string

 

of

 

three

 

characters

 

that

 

identify

 

it.

 

The

 

string

 

remains

 

displayed

 

for

 

one

 

sec

ond,

 

after

 

which

 

it

 

is

 

replaced

 

by

 

the

 

value

 

relative

 

to

 

the

 

parameter

 

itself.

 

To

 

pass

 

to

 

the

 

next

 

parameter,

 

use

 

the

 

arrow

 

keys

 

(Fig.B).

 

To

 

modify

 

a

 

parameter,

 

just

 

select

 

it,

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A),

 

mod

ify

 

the

 

value

 

using

 

the

 

arrow

 

keys

 

shown

 

in

 

(Fig.B).

 

To

 

confirm

 

the

 

modification

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A)

 

again.

 

 

 

 

 

7. LIST OF CONTROLS FOR THE GUIDED 

PROCEDURE 

How to modify a parameter in the user menu:

 

To

 

enter

 

the

 

USER menu 

press

 

the

 

key

 

shown

 

in

 

(Fig.A).

 

Once

 

the

 

key

 

has

 

been

 

pressed

 

the

 

password

 

must

 

be

 

inserted

 

for

 

access

 

to

 

the

 

various

 

menus.

 

To

 

access

 

the

 

user

 

menu

 

the

 

password

 

is

 

000 

(which

 

is

 

the

 

de

fault

 

displayed);

 

to

 

modify

 

the

 

value

 

of

 

the

 

password

 

use

 

the

 

arrow

 

keys.

 

Once

 

the

 

correct

 

password

 

has

 

been

 

inserted,

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A).

 

The

 

display

 

shows

 

the

 

index

 

of

 

the

 

USER 

parameter

 

and

 

a

 

string

 

of

 

three

 

characters

 

that

 

identify

 

it.

 

The

 

string

 

remains

 

displayed

 

for

 

one

 

second,

 

after

 

which

 

it

 

is

 

replaced

 

by

 

the

 

value

 

relative

 

to

 

the

 

parameter

 

itself.

 

To

 

pass

 

to

 

the

 

next

 

parameter,

 

use

 

the

 

arrow

 

keys

 

(Fig.B).

 

To

 

mod

ify

 

a

 

parameter,

 

just

 

select

 

it,

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A),

 

modify

 

the

 

value

 

using

 

the

 

arrow

 

keys

 

shown

 

in

 

(Fig.B).

 

To

 

confirm

 

the

 

modification

 

press

 

the

 

key

 

shown

 

in

 

(Fig.A)

 

again.

 

 

 

.

 

Содержание ANK

Страница 1: ... 7 5 7 WATER FLOW RATE ALARM 8 6 MAINTENANCE 8 6 1 HYDRAULIC CIRCUIT 8 6 2 ELECTRICAL CIRCUIT CHECKS 8 6 3 COOLING CIRCUIT CHECKS 8 6 4 MECHANICAL CHECKS 8 6 5 REFRIGERANT LOAD PROCEDURE 8 7 LIST OF CONTROLS 9 8 TROUBLESHOOTING 11 WIRING DIAGRAM 12 WARRANTY 13 ANK INSTALLATION MANUAL NORTH AMERICAN REVISION Table of contents GENERAL WARNING FOR THE INSTALLER The chiller must be installed by a qual...

Страница 2: ...ly most desirable Position the heat pump to avoid direct contact with water snow or ice from a roof line overhead The heat pump must be installed on a solid level mounting pad that will not settle or shift Isolate the pad from the building structure to avoid possible transmission of sound or vibration from the heat pump into the conditioned space The heat pump foundation should be raised to a mini...

Страница 3: ...gs connected from the disconnect to the heat pump shall be rated for outdoor use Check the heat pump rating plate and follow the appropriate instructions below NOTE All wiring must be suitable for outdoor use Use copper conductors only All field wiring must be done in accordance with National Electrical Code requirements applicable requirements of UL or local codes where applicable Electrical wiri...

Страница 4: ...sized minimum 1 inch Reducing fitting shall not be used Use care with the water glycol lines during the installation process If pex is used it can be cut by sharp objects Do not remove the caps from the lines or system connection points until connections are ready to be completed 1 Route the supply and return lines from the fittings on the indoor manifold or tank to the fittings on the heat pump R...

Страница 5: ...it Position the main system switch external to the appliance at ON 2 2ELECTRICAL CONNECTIONS The ANK heat pumps are completely wired at the factoryand only require connection to the electrical mains downstream from a unit switch according to that envisioned by the Standards in force on this subject in the country of installation It s also advised to check the following The electrical mains feature...

Страница 6: ...LED see subsequent pages 4 CONTROLS AND COMMISSIONING 4 1 PREPARATION FOR COMMISSIONING Before starting the unit make sure that 1 All safety conditions have been respected 2 The unit is correctly fixed to the support surface 3 The minimum technical spaces have been respected 4 The hydraulic connections have been made respecting theinlet and outlet 5 The hydraulic plant has been loaded and bled of ...

Страница 7: ...he temperature detected by the probe postioned at the outlet of the heat exchanger and in inlet to the chiller is below 4 C 39 F THIS ANTI FREEZE SET TEMPERATURE CAN ONLY BE VARIED BY AN AUTHORISED AFTER SALES CENTRE AND ONLY AFTER HAVING CHECKED THAT THERE IS ANTI FREEZE SOLUTION IN THE WATER SYSTEM The intervention of this alarm determines compressor stop and not pump block which remains active ...

Страница 8: ...WHENEVER THIS ALARM INTERVENES WE ADVISE YOU CALL THE NEAR EST AFTER SALES SERVICE IMMEDIATELY 5 7 WATER FLOW RATE ALARM The MODUCONTROL manages a water flow rate alarm controlled by the differential pressure switch installed in series on the machine This type of safety device intervenes after the first 40 seconds of pump function ing if the water flow rate is not sufficient The intervention of th...

Страница 9: ...in Fig B To confirm the modification press the key shown in Fig A again 7 LIST OF CONTROLS FOR THE GUIDED PROCEDURE How to modify a parameter in the user menu To enter the USER menu press the key shown in Fig A Once the key has been pressed the password must be inserted for access to the various menus To access the user menu the password is 000 which is the de fault displayed to modify the value o...

Страница 10: ...on 5 Envisioned Set the parameter ASA index A INSTALLER MENU with the value 1 4 Is a 3 way diverter valve envisioned in the DHW production circuit Reply Operations to be performed Not envisioned Go to question 5 Envisioned Set the parameter AAS index C INSTALLER menu with the appropriate value in seconds This parameter indicates the stand by tome for inversion of the 3 way diverter valve on the DH...

Страница 11: ...rational limits Check Pressure switch dysfunction Replace the component Circuit breaker protection interruption Check power supply voltage Check electric isolation of the windings High discharge pressure High external air temperature High water input temperature Check Insufficient air flow Insufficient water flow Check fan functioning Check pump functioning Fan regulation anomalous functioning Che...

Страница 12: ...iler control C F IA AE REF CEI EN 60335 2 40 ATTENTION all others give a reinforced insulation opposed to main power supply line Terminals 6 and 7 provide basic insulation 2RCR 1RCR RCR2 M7S 5 M7S 7 M7S 8 M1 8 M1S 8 M5S1 1 M5S1 2 M7 6 M7 5 M7S 4 M7S 3 RCR1 Contact between 4 5 opened unit off closed unit on Contact between 3 5 opened unit oin heating closed unit on Contact between 10 11 opened unit...

Страница 13: ...roper materials or workmanship as determined by MITS the company will at its sole discretion replace the defective part or component Conditions In the event MITS replaces a part or component the repaired or replaced product shall be warranted under the original limited warranty for the remainder of the original warranty period The warranty does not cover any failure of components not supplied by M...

Страница 14: ...nding Aermec reserves the right to apply at any time all the modifications deemed necessary for improving the product 1608 Bonhill Road Mississauga ON CA L5T 1C7 Phone 905 564 2221 Canada www aermec ca Toll Free 1 800 567 2221 US www aermec us Toll Free 1 888 567 2227 ...

Отзывы: