83
Surfacing from a Simulated Dive
The Simulator will enter
Demo Surface Mode
(Fig. 85) upon as-
cending to 3 feet (1 meter) or shallower.
Press and hold the Select (Bottom) button for 4 seconds to ac-
cess Time Acceleration. The small Time Clock icon will begin
flashing.
Tap (press/release) the Select (Bottom) button to increase Sur-
face Interval Time 1 minute per real time second.
Tap (press/release) the Select (Bottom) button during the Time
Acceleration to restore the time rate to normal.
FO2 can be set 10 minutes after surfacing.
Tap (press/release) the Advance (Front) button to access FO2
Set Mode. The FO2 graphic and value previously set will ap-
pear with the value flashing.
Press/release the Select (Bottom) button to increase the FO2
value in increments of 1%, or press and hold it to scroll.
Tap (press/release) the Advance (Front) button to accept the
FO2 setting and return to Demo Surface Mode.
To make another dive, press and hold the Select (Bottom) but-
ton for 2 seconds to access Dive Mode.
To revert operation to real Surface Mode (Fig. 86), press and
hold Both buttons simultaneously for 2 seconds.
Fig. 85 - Demo Surface Mode
Fig. 86 - Real Surface Mode