59
Delayed Violation Mode #2
(Fig. 55)
The ATMOS ai cannot calculate decompression times for Stop
Depths much greater than 60 feet (18 meters) and offers no indica-
tion of how much dive time would result in the need for a greater
Stop Depth.
If your Decompression obligation requires a Stop Depth 'be-
tween' 60 feet (18 meters) and 70 feet (21 meters),
the Nitrogen
Bar Graph will flash. Total Ascent Time will still be displayed.
You must ascend to just deeper than, and stay as close as possible
to, 60 feet (18 meters) without causing the Total Ascent Time dis-
play to flash. When the Required Stop Depth indicates 50 FT/ 15
M, etc., you can ascend to those depths and continue decompress-
ing.
Delayed Violation Mode #3
(Fig. 56)
If you descend deeper than 330 feet (100 meters),
the accumu-
lated Nitrogen Bar Graph segments will flash, and the Current
Depth and Max Depth displays will only indicate 3 dashes (
- - -
).
Upon ascending above 330 feet (100 meters), the Current Depth
display will be restored, however Max Depth will only display 3
dashes for the remainder of that dive. The Log for that dive will
also only indicate 3 dashes as the Max Depth achieved.
Fig. 56 - Delayed Violation #3
Flashing
Fig. 55 - Delayed Violation #2
Full BG Flashing
Содержание ATMOS ai