Aeris ATMOS ai Скачать руководство пользователя страница 1

ATMOS

DIVE COMPUTER

OPERATING MANUAL

ai

Содержание ATMOS ai

Страница 1: ...ATMOS DIVE COMPUTER OPERATING MANUAL ai...

Страница 2: ...ing design features Dive Time Remaining U S Patent no 4 586 136 Data Sensing and Processing Device U S Patent no 4 882 678 and Ascent Rate Indicator U S Patent no 5 156 055 User Setable Display U S Pa...

Страница 3: ...MATIONAL DISPLAYS 11 Tank Pressure Display 11 Depth Displays 11 Time and Date Displays 12 Temperature Display 12 AUDIBLE ALARM LED 13 BACKLIGHT 14 POWER SUPPLY 15 Battery Indicator 15 Low Battery Cond...

Страница 4: ...and Violation Gauge Mode 60 HIGH PO2 DIVE MODE 61 HIGH OXYGEN ACCUMULATION 64 USER SET DIGITAL GAUGE MODE 65 POST DIVE MODES 67 POST DIVE SURFACE MODE 68 TRANSITION PERIOD 68 AFTER THE TRANSITION PER...

Страница 5: ...L 85 CARE AND CLEANING 86 INSPECTIONS AND SERVICE 87 BATTERY REPLACEMENT 88 ALTITUDE SAMPLING COMPENSATION 93 SPECIFICATIONS 94 SERVICE RECORD 99 CONTENTS continued Pay special attention to items mark...

Страница 6: ...Mode g Icon Air Time Remaining h Icon Set Alarm i Icon Log Mode j Graphic Depth k Graphic Ascent Too Fast l Icon Operating Mode m Icon Time n Icon Safety Stop o Graphic Operating Mode p Graphic Pressu...

Страница 7: ...Prior to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well...

Страница 8: ...is complete Owner s Guide Remember that the rules you learned in your basic scuba certification course s still apply to the diving you will do while using a dive computer some will become even more im...

Страница 9: ...the Graph and as you ascend to shallower depths the Bar Graph will begin to recede indicating that additional no decompression time is allowed for multilevel diving The Nitrogen Bar Graph monitors 12...

Страница 10: ...resentation of ascent speed i e an ascent speedometer Green is a normal rate yellow a caution rate and red is Too Fast The segments of the Variable Ascent Rate Indicator represent 2 sets of speeds wh...

Страница 11: ...Displays During a dive the Current Depth display Fig 3b indicates depths from 0 to 330 feet 99 9 meters in 1 foot 1 meter increments The Maximum Depth reached during that dive will be displayed in the...

Страница 12: ...n of the window Fig 4b Both displays are identified by a clock icon Time of Day can be set for 12 hour format AM PM or 24 hour format Date is displayed in the lower screen only to identify dive data w...

Страница 13: ...is synchronized with the Audible Alarm and will indicate an Alarm when the unit emits a tone It will be OFF when the Alarm is acknowledged or Set OFF a user setting Warning situations that will sound...

Страница 14: ...check upon automatic return to Surface Mode from Simulator Mode upon completion of a fast battery change with calculations settings saved and upon change from Delayed to Full Violation after that dive...

Страница 15: ...d as a warning that the Battery is to be changed prior to conducting any fur ther dives with the unit If a Low Battery Condition exists when the unit is activated by pressing the button the Bat tery i...

Страница 16: ...wever oxygen related displays warnings and the O2 bar graph will not appear on the display for that dive or subse quent dives unless FO2 is set for a numerical value 21 50 Once a dive is made with the...

Страница 17: ...etitive nitrox dive or the value will automatically default to 50 and the dives will be calculated based on 50 O2 50 nitrogen for oxygen calcula tions and 21 O2 79 nitrogen for nitrogen calculations W...

Страница 18: ...your present depth before entering a decompression situation It is calculated based on the amount of nitrogen absorbed by hypothetical tissue compartments The rates each of these compartments absorb...

Страница 19: ...ss than the No Decompression Dive Time Remaining calculations for that depth will be controlled by oxygen Oxygen Time Remaining will then appear as the main numeric time display Fig 11b as signi fied...

Страница 20: ...ce with the tank pressure reserve that you selected during setup End Pressure Alarm Set Point When Air Time Remaining indicates zero Fig 12a you should immediately initiate a controlled ascent while m...

Страница 21: ...Prior to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well...

Страница 22: ...13 displaying all segments of the LCD as 8 s followed by dashes then a countdown from 9 to 0 The Backlight will be on Diagnostic Mode checks the display and battery voltage to ensure that everything...

Страница 23: ...the unit is rinsed and dried O will replace H2O WARNING If a Low Battery condition is displayed after diagnostics icon flashing DO NOT dive with the ATMOS ai until the Battery is changed While in the...

Страница 24: ...t to set by bypassing others The descriptions that follow describe access to each setting from Surface Mode Set Mode Access Timing While in Surface Mode press Both buttons simultaneously and hold afte...

Страница 25: ...er press from 21 to 50 then display Air again or Press and hold the Select Bottom button to scroll directly to 32 then press hold again to scroll to 50 and back to Air release at desired value For eac...

Страница 26: ...ng Press the Advance Front button 1 more time The graphics MAX FEET or M and dEEP and Alarm icon appear with the Max Depth value flashing Fig 20 Press and release the Select Bottom button until the de...

Страница 27: ...Advance Front button 2 more times The graphic EdT and Alarm and Dive Time icons appear with the Elapsed Dive Time value flashing Fig 21 Press and release the Select Side button until the desired Alarm...

Страница 28: ...Press the Advance Front button 3 more times The graphic PC appears with a 120 second countdown Fig 22 Download must be initiated before the countdown reaches 00 Download is initiated by the external...

Страница 29: ...or Met ric Press Both buttons simultaneously release when SET 2 ap pears Press and release the Advance Front button the Units screen appears with the graphics FT or M and the Temperature icon and lett...

Страница 30: ...Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 1 more time The graphic Hour appears with 12 or 24 flashing Fig 24 Press and release the Selec...

Страница 31: ...he Time of Day appears with the Hour value flashing Fig 25 Press and release the Select Bottom button to advance the Hour value in increments of one hour or press and hold to scroll Press the Advance...

Страница 32: ...ont button to accept the Year setting The Month value flashes Fig 28 Press and release the Select Bottom button to advance the Month value in increments of one Month or press and hold to scroll Press...

Страница 33: ...eously release when SET 2 ap pears Press and release the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 7 more times The graphic ALM and Alarm...

Страница 34: ...Front button the Units screen appears with the set point flashing Press the Advance Front button 8 more times The graphic ndc and Alarm icon appear with the full Nitrogen Bar Graph flashing Fig 31 Pr...

Страница 35: ...the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 9 more times The graphic trn and Alarm speaker icon appear with the Turn Pressure Alarm va...

Страница 36: ...the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 10 more times The graphic End and Alarm speaker icon appear with the End Pressure Alarm va...

Страница 37: ...ce Front button the Units screen appears with the set point flashing Press the Advance Front button 11 more times The graphic dtr and Alarm and Dive Mode icons appear with the Dive Time Remaining valu...

Страница 38: ...ton the Units screen appears with the set point flashing Press the Advance Front button 12 more times The graphics PO2 and MAX and Alarm icon appear with the PO2 value flashing Fig 35 Press and releas...

Страница 39: ...Press and release the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 13 more times The graphics FO2 and 50 appear with the ON or OFF flash in...

Страница 40: ...rs Press and release the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 14 more times The graphic GLO and Time icon appear with the Duration v...

Страница 41: ...ss Both buttons simultaneously release when SET 2 ap pears Press and release the Advance Front button the Units screen appears with the set point flashing Press the Advance Front button 15 more times...

Страница 42: ...urs after the dive Press Both buttons simultaneously release when SET 2 ap pears Press and release the Advance Front button the Units screen appears with the set point flashing Press the Advance Front...

Страница 43: ...prior to commencing a dive Press Both buttons simultaneously release when SET 2 ap pears Press and release the Advance Front button the Units screen appears with the set point flashing Press the Adva...

Страница 44: ...44 This page intentionally left blank...

Страница 45: ...Prior to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well...

Страница 46: ...t dive and surface interval To access the Dive Planner while in Surface Mode Press the Advance Front button 1 time Press and release the Select Bottom button to advance through the Depths Times availa...

Страница 47: ...umulation of oxygen if calcu lated to be oxygen controlled If the Nitrogen Bar Graph is displayed Fig 41 that next dive is controlled by nitrogen loading calculations If the O2 Bar Graph and O2 symbol...

Страница 48: ...erent Altitude than the Altitude at which it was activated Doing so will result in an error equal to the difference in barometric pressure and possibly a false dive mode with er roneous data The ATMOS...

Страница 49: ...r to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well as g...

Страница 50: ...cator Fig 43c shows how fast you are ascending When you exceed the maximum recommended ascent rate for the depth you are at it will enter the red Too Fast zone and you will be alerted by all segments...

Страница 51: ...or 7 seconds The Backlight will not activate during a Low Battery condition NO DECOMPRESSION DIVE MODE The ATMOS ai will enter the No Decompression Dive Mode when you descend deeper than 4 feet 1 2 m...

Страница 52: ...for Air press and hold the Advance Front button for 2 seconds to view the Secondary Display Air Time Remaining No Decompression Dive Mode Display 3 Fig 46 Information includes Current Depth Dive Time...

Страница 53: ...No Decompression dive in which depth exceeded 30 feet 9 meters a short beep will be emitted and a Safety Stop at 15 feet 4 5 meters will appear on the display with a 3 minute countdown timer that cou...

Страница 54: ...to a depth slightly deeper than or equal to the Required Stop Depth indicated Fig 49a and decompress for the Stop Time indicated Fig 49b The UP Arrow and Deco Bar will flash if you are greater than 10...

Страница 55: ...n includes Current Depth Total Ascent Time and Mode icon required decompression Stop Depth and Time both Arrows and the Deco Bar Tank Pressure and applicable bar graphs press hold the Advance Front bu...

Страница 56: ...view another display of information WARNING If you exceed certain limits the ATMOS ai will not be able to tell you how to get safely back to the surface These situations exceed tested limits and can...

Страница 57: ...to the Main Display after 3 seconds unless the Advance Front button is pressed to view another display of information Conditional Violation Mode The ATMOS ai will enter the Conditional Violation Mode...

Страница 58: ...pression Stop Depths and Time will decrease toward zero then the Nitrogen Bar Graph will recede into the yel low Caution Zone and the ATMOS ai will revert to the No Decompression Dive Mode NOTE Upon e...

Страница 59: ...s without causing the Total Ascent Time dis play to flash When the Required Stop Depth indicates 50 FT 15 M etc you can ascend to those depths and continue decompress ing Delayed Violation Mode 3 Fig...

Страница 60: ...ion would be preceded by entering Delayed Violation Mode 2 previously described The ATMOS ai would then operate with limited functions in Violation Gauge Mode during the remainder of that dive and for...

Страница 61: ...rm you of the time remaining before normal opera tion can resume with full ATMOS ai features and functions NOTE This condition is considered a Permanent Violation and in the event that a dive is made...

Страница 62: ...d a maximum value of 5 00 ATA in increments of 01 ATA When it reaches a value of 1 60 ATA or the PO2 Alarm set point a user setting the red LED will flash the Audible Alarm will sound unless set OFF a...

Страница 63: ...s you conduct during that 24 hour period whichever of the two is greater at that time The yellow Caution Zone of the O2 Bar Graph offers you a convenient way to consistently moni tor how close you are...

Страница 64: ...ace interval of at least 2 hours before reentering the water If you exceed the maximum 24 hour period allowable oxygen exposure dose you must allow a surface interval of at least 24 hours before reent...

Страница 65: ...beyond the normal depth limit of the unit Information displayed Fig 62 includes Current Depth Elapsed Dive Time Maximum Depth Time of Day Tank Pressure if in use and graphic GAUGE To view the Secondar...

Страница 66: ...decompression dives is extremely limited and virtually non existent for repetitive decompression diving Decompression diving greatly increases your risk of decompression sick ness Special training eq...

Страница 67: ...ior to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well as...

Страница 68: ...that dive during that activation period Surface Interval time colon flashing and icon flashing Temperature ambient Time of Day and icon Battery Indicator Tank Pressure and graphic Nitrogen Bar Graph i...

Страница 69: ...Surface Mode after 2 min utes if no button is pressed Log Data will not be stored in the unit s memory until the 10 minute Transition Period on the surface is completed Once 10 minutes have elapsed t...

Страница 70: ...press release the Select Bottom button to advance through the sequence of available depths times one screen at a time The unit will revert to Surface Mode after 2 minutes unless the Advance Front butt...

Страница 71: ...own 10 minutes after sur facing from a dive after the 10 minute Transition Period display ing the graphic FLY and a countdown that begins at 23 50 hr min and counts down to 0 00 hr min To access the T...

Страница 72: ...our diving involved de compression or a repetitive multi day profile it is strongly recommended that you wait a full 24 hours after your last dive to add a greater degree of protection As you should b...

Страница 73: ...hile in Log Mode press Both buttons simultaneously for 2 seconds The unit will automatically revert to Surface Mode after 2 minutes if no button is pressed while in the Log Mode HINT To bypass a dive...

Страница 74: ...ate maintained for 4 consecutive seconds during the dive Nitrogen Bar Graph showing tissue nitrogen loading at the time you surfaced at the end of the dive Also the segment that re flects the maximum...

Страница 75: ...wns after 2 hours if no button is pressed Wet Contacts If the graphic H2O appears during the Fly Mode Fig 73 and Desaturation Mode Fig 74 countdowns it is an indication that the water activation conta...

Страница 76: ...ealer The software program provides tabular and graphic profile data sampled throughout the dives See page 41 for setting Sampling Rate The Interface Cable will be connected to the Data Port located o...

Страница 77: ...Prior to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well...

Страница 78: ...OFF calculations to be cleared and FO2 to be set Access and Setup while in real Surface Mode Press and hold Both buttons for 6 seconds Release the buttons during the 2 second window when SIM and DEMO...

Страница 79: ...to accept the setting and advance to DEMO PSI or bAr with OFF CYL 3000 psi 206 5 bar or 4000 psi 275 5 bar flashing Fig 79 When set for OFF no calculations are made and no displays ap pear relating t...

Страница 80: ...pressing and releasing the Select Bottom button ad vances the FO2 setting from AIR to 21 through 50 in incre ments of 1 per button depression no scroll The Maximum Depth allowed for the PO2 Alarm Set...

Страница 81: ...tton during the De scent or stopped to access the Alternate Displays Press and hold the Select Bottom button for 4 seconds to ac cess Time Acceleration The small clock icon begins flashing Fig 82 Tap...

Страница 82: ...hic TOO FAST Fig 84 The Alarm will sound and the red LED will flash Pressing and holding the Advance Front button for 2 seconds will return the Rate to 1 fps Tap press release the Advance Front button...

Страница 83: ...to normal FO2 can be set 10 minutes after surfacing Tap press release the Advance Front button to access FO2 Set Mode The FO2 graphic and value previously set will ap pear with the value flashing Pre...

Страница 84: ...l press the Advance Front button one 1 time to access PLAN MODE While 30 feet or 9 meters is displayed in the PLAN MODE press and hold Both buttons until SET 2 appears then release the buttons Press a...

Страница 85: ...to diving with the ATMOS ai you must also read and understand the AERIS Dive Computer Safety Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well as gen...

Страница 86: ...of diving and check to ensure that the areas around the low pressure depth sensor Fig 87a download interface Data Port Fig 87b and buttons are free of debris or obstructions To dissolve salt crystals...

Страница 87: ...ue to have this inspection performed every year to ensure it is working properly The costs of annual inspections are not covered under the terms of the 2 year limited warranty WARNING If you are in do...

Страница 88: ...od to the nearest AERIS Regional Ser vice Facility or to AERIS Non warranty service must also be prepaid call for an estimate COD is not accepted If you have any questions regarding service call AERIS...

Страница 89: ...r the Aeris factory WARNING If damage moisture or corrosion is found it is recommended that you return your ATMOSai to an Authorized AERIS Dealer and DO NOT attempt to use it until it has received fac...

Страница 90: ...ossible injury or death Indication of tampering with the module will void the unit s warranty Turn the unit over to drop out the Battery Discard of properly Check the metal contacts inside the Battery...

Страница 91: ...nuine AERIS part that can be purchased from an Authorized AERIS Dealer Use of any other O ring will void the war ranty CAUTION Avoid touching the Battery Contacts or flat surfaces of the Battery skin...

Страница 92: ...ace Mode Observe the LCD display to ensure it is consistently clear and sharp in contrast throughout the screen WARNING If any portions of the display are miss ing or appear dim or a Low Battery Condi...

Страница 93: ...inutes while it is acti vated or every 30 minutes when it is not activated At an Altitude of 2 000 feet 610 meters it will automatically recalibrate itself to measure depth in feet of fresh water rath...

Страница 94: ...Limits Based on NOAA tables OPERATIONAL MODES Activation Diagnostic Surface Dive Planner Time to Fly Countdown Desaturation Countdown Dive Log Date Time Nitrogen Oxygen Set Mode 1 FO2 Air 21 50 Max De...

Страница 95: ...ive Current Depth Total Ascent Time Current PO2 value Bar Graphs Secondary Current Depth Air Time Remaining Stop Depth Time Tank Pressure Bar Graphs Violation types Conditional Delayed and Immediate G...

Страница 96: ...RAPHS Nitrogen Bar Graph segments Oxygen O2 Bar Graph segments No Decompression zone green 5 Normal zone green 3 No Deco Caution zone yellow 2 Caution zone yellow 1 Decompression Warning zone red 1 Da...

Страница 97: ...4 dives adds 25th dive in memory and deletes the first dive Altitude Operational from sea level to 14 000 feet 4 267 meters elevation Compensates for Altitude at elevations higher than 2 000 feet 610...

Страница 98: ...l reactivate if the H2O graphic is displayed Cannot be shut off manually Setting FO2 Automatically set for Air upon activation Remains set for Air unless an FO2 numerical value is set Nitrox set point...

Страница 99: ...ev Number __________________ Date of purchase _____________________ Purchased from ______________________ Below to be filled in by an Authorized AERIS Dealer R E S P O NSIBLE D I V E R Date Inspection...

Страница 100: ...Doc No 12 7153 r02 7 3 06 2002 Design 2002 AERIS 2002 Davis Street San Leandro CA 94577 Tel 510 346 0010 Fax 510 346 0015 Web site http www diveaeris com E mail info2 diveaeris com...

Отзывы: