TROUBLESHOOTING 

 

 

 

 

Page 26 of 32 

8  Troubleshooting 

If problems arise with the dehumidifier please check the following points. Should 

the fault not be located please contact your technical advisor. 

 

WARNING 

Danger of injury by electric shock and risk of material 

damage 

  The air dehumidifier may only be repaired by trained 

specialised staff. Within the warranty period, any work 

on the dehumidifier shall only be carried out by the 

manufacturer or persons commissioned by the 

manufacturer. Any work carried out by unauthorised 

persons shall lead to the forfeiture of all warranty 

claims! 

 

Problem 

Possible cause 

Remedy 

Air dehumidifier 

shows poor or no 

humidification 
performance. 

The ambient humidity is 

lower than 40% r. h. or 

the ambient temperature 
is less than +3 °C. Under 

these conditions 

operation of the air 

dehumidifier is 

uneconomical. 

Switch the air dehumidifier off.  

Tip: set the hygrostat to an 

achievable value  
(e.g. to about 50% r. h.) to ensure 

that the dehumidifier will switch 

off in time in respect of the 

ambient humidity. 

The air filter is severely 
soiled. The air flow is 

insufficient. In the long 

run, soiled filters can 

cause damage to the air 

dehumidifier. 

Clean or, if required, replace the 
filter. 

Tip: perform maintenance as 

described in chapter 7 at regular 

intervals! Use only original  

AERIAL

 air filters. 

Compressor and/or fan 

motor are/is defective. 

Entrust a specialised company 

with the repair of the air 

dehumidifier.  

Содержание AD 420

Страница 1: ...MADE IN GERMANY AD 420 430 11 2013 Rev 3 EN INSTRUCTION MANUAL Air Dehumidifier Series AD 420 AD 430...

Страница 2: ......

Страница 3: ...hts reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manual Any use of...

Страница 4: ...___ 10 Pump out kit for condensate___________________________________ 10 Method of operation _________________________________________ 11 5 Transport and installation _________________________________...

Страница 5: ...________________________________________ 29 Storage ___________________________________________________ 29 Disposal __________________________________________________ 30 10 Technical specifications __...

Страница 6: ...keep this instruction manual in a safe place In the section below you will find information about the target groups of this instruction manual and the conventions used in this document Target groups T...

Страница 7: ...occurs are described in this way WARNING Type and source of hazard This symbol in connection with the word Warning warns of a risk involving severe injury Measures to avert danger or immediate measure...

Страница 8: ...ories Waste water hoses and air filters must be properly installed and must not disable the protection devices of the condensation dryers The operating elements must always be accessible Authorised op...

Страница 9: ...increased lime deposits In rooms with salt or liquids with a salt content 1 incl brine baths In rooms with ozone treated air In rooms with high solvent concentration In rooms with extreme dust load P...

Страница 10: ...limits of designated use also involves observing the specified operating conditions refer to page 15 Any use of the air dehumidifier not in conformity with or going beyond the designated use is consid...

Страница 11: ...ally a wall bracket is available for stationary attachment to a wall Fig 1 AD 420 430 series air dehumidifier isometric view 1 Carrying handle 4 Operating panel 2 Front wall air outlet 5 Ventilation p...

Страница 12: ...intake area with air filter 5 AMP connector for connecting a pump out kit with dummy plug for operation without pump 3 Condensate drain pipe for condensate drain hose The water collecting tank is loca...

Страница 13: ...AD 420 430 air dehumidifiers can be equipped with a pump out kit Ask your AERIAL dealer for the pump out kit It can be installed in just a few steps and can be removed just as quickly too Fig 3 Pump...

Страница 14: ...principle of condensation with heat recovery The fan Fig 4 item 4 draws the moist air in through a cooling coil evaporator Fig 4 item 2 In the cooling coil the air is cooled so far below the dew point...

Страница 15: ...ipping CAUTION Material damage Pulling the power cable may damage the cable Always disconnect the mains plug from the socket outlet before transport Always use the carrying handles to transport the ai...

Страница 16: ...ording to the local regulations 3 Check the delivery refer to page 7 for completeness 4 Should any transport damage be detected after unpacking of the air dehumidifier or should the delivery be incomp...

Страница 17: ...ce due to improper operating conditions improper installation Ensure that the wall is suitable for attachment of the wall bracket and can carry the weight of the air dehumidifier Attach the air dehumi...

Страница 18: ...ons can result in damage problems in case of immediate switching on Therefore allow the air dehumidifier to adjust to the temperature before switching it on The suitable location for the air dehumidif...

Страница 19: ...of installation The following items must be checked prior to electrical connection of the air dehumidifier Is the mains voltage in conformity with the voltage of the air dehumidifier Are socket and su...

Страница 20: ...metre Do not immerse the hose end in water water back up may occur Never bend the hose Do not place any objects on the hose Check regularly whether condensate is properly discharged 1 Remove the wate...

Страница 21: ...r 4 Ensure that the turn lock has been turned fully to the left horizontal position The bottom rabbet of the pump out kit rear wall must engage in the bottom edge of the water tank compartment 5 Put t...

Страница 22: ...xample before transport of the air dehumidifier We recommend to empty the pump whenever the air dehumidifier is to be transported because otherwise water may flow out when the device is tilted To remo...

Страница 23: ...nditions or improper operation of the air dehumidifier may constitute a risk Read the instruction manual before commissioning the air dehumidifier Series AD 420 430 operating elements Fig 5 Series AD...

Страница 24: ...sition 80 100 The air dehumidifier will switch off at a relative humidity of about 80 95 and switch on again when a humidity of 80 95 is exceeded Position 60 80 The air dehumidifier will switch off at...

Страница 25: ...Fig 5 item 1 If the air dehumidifier has been correctly connected and the existing humidity is higher than the set humidity value the air dehumidifier will start to work Operator control 1 Select the...

Страница 26: ...area of the evaporator It transmits the defrost signal to the DryLogic electronics which will determine the defrosting demand and automatically start the defrost cycle During the defrost cycle the co...

Страница 27: ...cleaning with compressed air WARNING Danger of injury due to sharp edged lamellae Wear protective gloves during cleaning of the heat exchanger CAUTION Damage to the appliance Cleaning agents can caus...

Страница 28: ...Visual inspection collecting tank drain pipe and connected hose if any 10 Clean casing on the outside with a moist cloth do not use any aggressive detergent 11 Insert new or cleaned filter Use only o...

Страница 29: ...Air dehumidifier shows poor or no humidification performance The ambient humidity is lower than 40 r h or the ambient temperature is less than 3 C Under these conditions operation of the air dehumidi...

Страница 30: ...he air dehumidifier on Air dehumidifier without power supply Have the power cable the plug connection any extension cable used the plug socket and the building fusing checked by an expert Connect the...

Страница 31: ...onments The humidity set on the hygrostat is not achieved or the air dehumidifier does not automatically switch off Hygrostat set to a value 45 r h Depending on the ambient conditions your air dehumid...

Страница 32: ...m dust Storage To store a single air dehumidifier we recommend to proceed as follows 1 Package the air dehumidifier using cardboard 2 Store the air dehumidifier in conformity with the specified operat...

Страница 33: ...to leave the top side completely free This allows storage of another air dehumidifier of this type stacked on top of the lower unit Disposal Please do not dispose of this air dehumidifier with the do...

Страница 34: ...on for indoor swimming pools RCCB to be installed by user Operating conditions 3 C to 32 C 40 r h to 95 r h Type Unit AD 420 AD 430 Air circulation rate Fan speed I cbm h 300 500 Fan speed II cbm h 39...

Страница 35: ...430 The product described is an air dehumidifier ready for connection Applicable standards EN ISO 12100 Safety of Machinery EN 61 000 Electromagnetic Compatibility EMC EN 60 335 2 40 Safety of electri...

Страница 36: ......

Страница 37: ...aerial de Internet www aerial de Branch Switzerland T fernstrasse 20 CH 5405 Baden D ttwil Phone 0041 56 470 21 55 Telefax 56 470 21 57 E Mail info aerial ch Internet www aerial ch klima24 ch Branch...

Отзывы: