6.
MAINTENANCE
6.1.
Prior warnings
Before doing any work on the appliance:
The appliance may still be charged even though the 230 VAC power supply circuit has been cut off,
leading to a risk of electrical shocks.
➔
Wait at least 5 min after cutting off the power supply before intervention on the appliance.
The appliance may be stopped but restarts automatically (for example if there is a momentary
interruption in the control circuit of the MS version), with a risk of injury.
➔
Never insert anything through the fan, in particular at the suction stream in which the turbine is located.
➔
Never handle an appliance or remove it from its stack when it is live.
➔
Cut off the power supply and make sure that it cannot be reconnected.
➔
Wait for the turbine to come to a full stop.
6.2.
Maintenance and cleaning
We recommend carrying out a visual observation of the proper operation of each fan and cleaning its blades once a year:
1) Cut off the power supply.
2) Remove the product from the base on which it is placed in order to reach the turbine.
Wearing suitable gloves while handling the product is strongly recommended (some of the metal
parts have sharp edges).
3) Using a cloth moistened with a cleaning product or a brush, which should be non-metallic so as not to damage the
galvanization, clean the blades of the turbine and the fixed vanes.
Take care not to twist the blades or the vanes of the fan during this operation. Do not apply solvent
on the ball bearings (this might impair their lubrication).
4) Wipe with a dry cloth
5) Put the fan back in place
6) Reconnect the power supply. In the MS mode, restarting will take a few minutes, the time needed to reset the modules.
Door access to VBP+ C4 :
We recommend carrying out a visual observation of the proper operation of each fan once a year
and if necessary,
cleaning its blades.
1)
Cut the plastic clips that secure the access hatch to the fixed
part of the fence.
DO NOT CUT the metallic staple linking the access hatch to the
support.
2)
Open to clean the inside of the fan.
3)