8
Installation type can be selected using JUMPER 1 between the following options:
through wall or ducted (fig. 15).
instAllAtion tYPe settinG
Trickle speed can be selected using JUMPER (fig. 15).
tricKle sPeed settinG
to 95% Relative Humidity via dedicated trimmer, and with a timer which is adjustable
from 0 to approx. 30 minutes via dedicated trimmer (fig. 14B).
The fan runs continuously at selected trickle speed (set by the jumper switch
combination fig. 15), increases its speed in case the percentage of Relative Humidity
exceeds the settable threshold, and can anyway be boosted with a dedicated ON/
OFF switch (or PIR, CO2…sensor) or with a light switch (fig. 13B). Trickle speed can
be set to off (fig. 15).
To deactivate the humidistat function, turn the trimmer HY completely clockwise.
Automatic humidistat operation: when the percentage of Relative Humidity exceeds
the settable threshold, fan speed automatically increases to “comfort boost” speed,
(intermediate between the selected trickle speed and the boost speed). When the
percentage of Relative Humidity goes below the threshold, the fan continues to function
at “comfort boost” speed for a factory set period of time then returns to selected trickle
speed.
Operation with external switch: (fig. 13B). When the external switch is turned on, the
fan is boosted. After the external switch is turned off, the fan continues to run at boost
speed for a settable period of time, then it returns to selected trickle speed (or to
“comfort boost” speed in case automatic humidistat operation is on). The front cover
LED indicates when the external switch is on.
The over-run timer function is activated only if the external switch has been on for at
least 60 seconds.
2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following
standards:
Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2.
Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3-
2(2014); EN 61000-3-3(2013).
stAndArd conForMitY
Information on disposal of units at the end of life.
This product complies with EU Directive 2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be
collected separately from other waste at the end of its life. The user must,
therefore, dispose of the product in question at suitable electronic and
electro-technical waste disposal collection centres, or else send the
product back to the retailer when purchasing a new, equivalent type device.
Separate collection of decommissioned equipment for recycling, treatment
and environmentally compatible disposal helps to prevent negative effects
on the environment and on health and promotes the recycling of the
materials that make up the equipment.
Improper disposal of the product by the user may result in administrative
sanctions as provided by law.
disPosAl And recYclinG