REVISIONE
NON SCALARE DISEGNO
FOGLIO 1 DI 1
A0
PESO:
fig-8
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
K
K
L
L
M
M
N
N
P
P
R
R
T
T
24
24
23
23
22
22
21
21
20
20
19
19
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
N. DISEGNO
SCALA:1:1
TITOLO:
MATERIALE:
DATA
DISEG.
VERIF.
APPR.
FABB.
Qual.
ANGOLARE:
FINITURA:
LINEARE:
BORDI NETTI
NOME
FIRMA
SE NON SPECIFICATO:
QUOTE IN MILLIMETRI
FINITURA SUPERFICIE:
TOLLERANZE:
INTERRUZIONE
QR
3.5 Rating label
3.4 space required
Make sure that enough space is left around the unit to allow easy maintenance (access to filters, terminal box and removal of the
side and front inspection panels).
To set the RIGHT orientation of the machine:
• Modify the orientation on the CTRL-DSP (§ 7.2 - Installer menu: 3 Machine Orientation).
• For the QR400 and QR550 units move the F7 filter from the left to the right side.
• Replace the ducting connection label on the top of the casing and the water drainage label on the bottom of the casing with
those supplied with this installation manual.
fig.3.c
Rating label
fig. 3.b
Connections in LEFT and RIGHT orientation - QR400A e QR550A.
4 tRAnsPoRt And stoRAGe
The appliance is delivered in one carton box.
The appliance should be stored and transported in such a way that it is protected against physical damage that can harm spigots,
casing, display etc...
It should be covered so that dust, rain and snow cannot enter and damage the unit and its components.
WARninG
Make sure that specific warnings and cautions in Chapter 2 “Precautions” are carefully read, understood and applied!
5 instAllAtion
This section describes how to install the unit correctly.
the unit must be installed according to these instructions.
5.1 unpacking
Verify that the unit (and eventual accessories) delivered is according to order before starting the installation. Any discrepancies
from the ordered equipment must be reported to the supplier.
5.2 Where/how to install
• All QR units are meant for indoor installation in a heated space.
• Mount the unit on flat surface (wall).
WARninG
Make sure that specific warnings and cautions in Chapter 2 “Precautions” are carefully read, understood and applied!
A
B
C
D
E
F
QR400A - QR550A
LEFT
A
Intake air from outside
B
Exhaust air to outside
C
Supply air to inside
D
Extract air from inside
E
Winter condensation drainage
F
Summer condensation drainage
RIGHT
A
Extract air from inside
B
Supply air to inside
C
Exhaust air to outside
D
Intake air from outside
E
Summer condensation drainage
F
Winter condensation drainage
Содержание QR280A
Страница 1: ...QR280A QR400A QR550A aL ...