14
3.4 Rating labels
3.3 Space required
Make sure that enough space is left around the unit to allow easy maintenance (access to filters, terminal box and inspection
panel removal).
3.2 Dimensions (mm) and Weight (kg)
Fig.3.c
Rating labels.
4 TRANSPORT AND STORAGE
The appliance is delivered in one carton box.
The appliance should be stored and transported in such a way that it is protected against physical damage that can harm spigots,
casing, display etc...
It should be covered so that dust, rain and snow cannot enter and damage the unit and its components.
5 INSTALLATION
This section describes how to install the unit correctly.
The unit must be installed according to these instructions.
5.1 Unpacking
Verify that the unit (and eventual accessories) delivered is according to order before starting the installation. Any discrepancies
from the ordered equipment must be reported to the supplier.
5.2 Where/how to install
• AIRQURE P1 unit are meant for indoor installation in a heated space.
• The unit should be mounted horizontally.
• Mount the unit on flat surface (ceiling or floor).
•
It’s important that the unit is completely leveled before it is put into operation.
•
When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspection door
should be easily accessible.
•
Leave free space for opening the removable panel and for removal of the main components
Weight
8,3
386
247
457
500
44
Ø124,5
506
385 404
WARNING
Make sure that specific warnings and cautions in Chapter 2
“Precautions” are carefully read, understood and applied!
WARNING
Make sure that specific warnings and cautions in Chapter 2
“Precautions” are carefully read, understood and applied!
15
1. Ventilation unit
4. Manual
7. 2x Metal clamps
2. Pre-Filter
5. Diffuser
8. 2x Mylar flap
3. Duct
6. wall plugs
Fig. 5.a
Fig. 5.b
5.3 What is in the box
5.4 Diffuser Installation
When fitting the diffuser near a smoke alarm the blanking plates provided must be fitted to avoid blowing air over the smoke
alarm and affecting its operation. If the unit is installed in a dwelling 3 storeys or above, it should be linked to a smoke alarm
in such a way that power is removed from the unit if the smoke alarm is activated. Our standard diffuser is not suitable for
installation in 3 storey or above homes or fire protected areas.
In case of installation of the AIRQURE P1-H model (with heating element) the flexible duct should be the shortest possible.
Alternatively use a thermal insulated duct (accessory on request).
Fig. 5.c
Fig 5.d
5.5 Ceiling installation
The unit must be installed in the following position.
Fig. 5.e
Spirit level
Fig. 5.f
5.e
Prepare the surface where the unit is to be mounted. Make sure that the surface is flat, leveled and that it supports the weight
of the unit. Perform the installation in accordance with local rules and regulations.
5.f
Use appropriate screws (not supplied) to fix the unit to the ceiling. It is recommended to fit the unit with anti-vibration mounts
(not supplied).