BC 2000 DIGITAL
Audio Routing, Mixing and Processing System for Program Production Centres
.
ARENA DM CONTROL SURFACE
FUNCTIONAL DESCRIPTION
36
3.2.3. Working Configuration display.
The Working Configuration screen is accessed by pressing the button under the “Working
Config.” label in the Select access area. It looks as follows:
From this screen different available options can be selected through the P1 to P5 push-buttons
placed under these options.
3.2.3.1. Loading a new configuration.
1º. Using the E2 central rotating encoder scroll up and down on the list of configurations
available, until reaching the new configuration, which will be loaded (the
configuration appears highlighted).
2º. Once the desired configuration is highlighted the E2 encoder (“SELECT NEW”)
must be pressed, in order to place the selected option into the New Selected area.
No configuration has been loaded yet; it has only been selected. The same
configuration still appears as the active configuration (“Current Work Config.”),
although now the new one appears on “New Selected“ area. If a wrong configuration
has been selected press “CANCEL SELECTN.” to cancel the selection or press
“MAIN SCREEN” to go back.
3º. The effective load of the new configuration is made by pressing under “LOAD
SELECTN.”, although the system asks the user for a confirmation. If the load is
accepted
,
press under the “YES” label (pushbutton P1). Choosing the “CANCEL”
label returns the user to the main screen, cancelling the new selection.