background image

29-1-2019

TriSensor user guide. : Aeotec

https://aeotec.freshdesk.com/support/solutions/articles/6000195459-trisensor-user-guide-

12/18

 
A Group Association is a specific function in Z-Wave that allows you to tell the TriSensor who it can speak to. Some
devices may only have 1 group association meant for the gateway, or multiple group associations that can be used for
specific events. This type of function isn't used too often, but when it is available, you may be able to use it to directly
communicate to Z-Wave devices instead of controlling a scene within a gateway which can have unforeseen delays.
 
Vera has the ability to set Group Associations to devices that have these special events and functions. In TriSensor
case, it can speak directly to the devices it is associated to for directly toggling On/Off controls via temperature or
motion sensor triggers without communicating to your gateway.
 
For example:

Using Group associations will talk directly to a Z-Wave device, this will process less than 1 second usually within
10-100ms.
Triggering a scene, a device will need to update its status to your gateway, then have the gateway process the
status update then send an action or change to a Z-Wave device based on the trigger. Sometimes there may be
delays if your gateway is already processing other data which can cause 1-2 second delays from time to time. 

 

How many devices you can control.

You can control 5 devices per Group Association for a total of 10 separate devices per button over 2 different Group
Associations 

Example;

5 devices on Group 2 (motion sensor control)
5 devices on Group 3 (temperature sensor control)

 

How do I control my devices using group association?

This is a bit difficult as many gateways provide this function and just as many gateways will not provide an option to
program this. You'll need to look into your gateways functions and see if they support "Group Association" and how to
do it.
 

5. Enable or disable Group 2 or 3 group association for direct control.

This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group
2 and group 3.

 

Parameter

Size Value Description 

Disabled All Group Basic Set Command 

 

 

Enabled Group 2 Basic Set Command, Group 3
Basic Set Command is disabled. 

 

 

Enabled Group 3 Basic Set Command, Group 2
Basic Set Command is disabled. 

 

 

Enabled Group 2 and Group 3 Basic Set
Command. 

DEFAULT SETTING = 3
 

6. Basic Set controls for Group 2.

This setting gives you more control as to how Group 2 is controlled by your motion sensor.

 

Parameter

Size Value Description 

Содержание TriSensor

Страница 1: ...ps aeotec com z wave motion sensor To see whether TriSensor is known to be compatible with your Z Wave system or not please reference our Z Wave gateway comparison http aeotec com z wave gateways list...

Страница 2: ...seconds Health Test Press and hold for 15 seconds Factory Reset Important safety information Please read this and other device guides carefully Failure to follow the recommendations set forth by Aeote...

Страница 3: ...your TriSensor into a Z Wave Network With it powered on it s now time to add your TriSensor to a Z Wave network To pair TriSensor you are not limited to only the Z Stick or Minimote You may use any Z...

Страница 4: ...ill deactivate without flashing white or green 3 You can test if your TriSensor has been successfully included into your Z Wave network by pressing its Action Button If you press the button and your s...

Страница 5: ...eing false motion tracking run trial and error to determine the best sensitivity from a range of 0 11 by going down 1 sensitivity level after every test first 5 4 3 2 then 1 while setting Parameter 3...

Страница 6: ...suggest you choose the second method using screws to affix the Back Mount Arm which would be more stable 2 After you have completed the affixing of Back Mount Arm you will need to lock TriSensor to t...

Страница 7: ...placement is necessary Recommendation For networks which do not offer a method to display For the battery level of your TriSensor it is recommended that the sensor be tested occasionally to ensure tha...

Страница 8: ...on 1 Remove TriSensors battery cover by unlocking then removing the cover 2 Press and hold TriSensors Action Button until LED turns yellow 5 seconds of holding 3 Release TriSensors button If you were...

Страница 9: ...etwork Your TriSensor can be removed from your Z Wave network at anytime You ll need to use your Z Wave network s main controller to do this and the following instructions tell you how to do this usin...

Страница 10: ...pdesk attachments 6064224662 Monitoring motion When TriSensor detects a motion event it will automatically send a notification report to Group 1 which is usually automatically set to report to your ga...

Страница 11: ...gateways that use the older style of motion reports If you do not see status changes over your motion sensor you must enable this setting Command Class COMMAND_CLASS_SENSOR_BINARY Command SENSOR_BINA...

Страница 12: ...or change to a Z Wave device based on the trigger Sometimes there may be delays if your gateway is already processing other data which can cause 1 2 second delays from time to time How many devices yo...

Страница 13: ...leared DEFAULT SETTING 0 7 Temperature Alarm Setting Group 3 control This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is lar...

Страница 14: ...rature report Parameter SizeValueDescription 12 1 0 Disable Default 1 Red 2 Green 3 Blue 4 Yelllow 5 Pink 6 Cyan 7 Purple 8 Orange 13 Light report LED This setting changes the color of the LED when yo...

Страница 15: ...0 US 1 0 1 1 Value and Description 0 Celcius 1 Fahrenheit 21 Temperature Threshold reporting Change threshold value for change in temperature to induce an automatic report for temperature sensor Scal...

Страница 16: ...22 Light Threshold Report Change threshold value for change in light sensor to induce an automatic report for temperature sensor Scale Lux Parameter SizeValue Description 22 2 0 Disable Threshold Rep...

Страница 17: ...92B29I https www amazon com HDE LX 1010B Digital Luxmeter Display dp B00992B29I This is purely an example the more accurate lux meter you have the better calibration setting you will be able to use 1...

Страница 18: ...29 1 2019 TriSensor user guide Aeotec https aeotec freshdesk com support solutions articles 6000195459 trisensor user guide 18 18...

Отзывы: