Aeotec TriSensor Скачать руководство пользователя страница 9

29-1-2019

TriSensor user guide. : Aeotec

https://aeotec.freshdesk.com/support/solutions/articles/6000195459-trisensor-user-guide-

9/18

Green = Great Health

 

Manually Factory Reset TriSensor.

 
This method is not fully advised unless your gateway has failed, and you do not yet have another gateway to perform a
general unpair on TriSensor. 

1. Press and hold TriSensor Action button 
2. Wait until the RGB LED turns from: 

- Red 
- Orange 
- Cyan 
- Red LED flashes 5 times which will indicate a factory reset. 

3. If your TriSensor has been successfully factory reset from its previous network, the LED will become a solid

yellow when you tap its Action Button. If this has failed, the LED will become a solid purple color for 2 seconds
when you tap the Action Button.

 

Removing your TriSensor from Z-Wave Network.

 
Your TriSensor can be removed from your Z-Wave network at anytime.You'll need to use your Z-Wave network's main
controller to do this and the following instructions tell you how to do this using Aeotec by Aeon Labs' Z-Stick and
Minimote controllers. If you are using other products as your main Z-Wave controller, please refer to the part of their
respective manuals that tells you how remove devices from your network. 
 

If you're using a Z-Stick:

 
1. If your Z-Stick is plugged into a gateway or a computer, unplug it. 
 
2. Take your Z-Stick to your TriSensor.
 
3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.
 
4. Press the Action Button on your TriSensor 3x times within 2 seconds. The LED on TriSensor will become a solid
purple color.
 
5. If your TriSensor has been successfully removed from your network, the LED will flash white, green, white, green
(white, then green 2x times).
 
6. Press the Action Button on the Z-Stick to take it out of removal mode.
 

Содержание TriSensor

Страница 1: ...ps aeotec com z wave motion sensor To see whether TriSensor is known to be compatible with your Z Wave system or not please reference our Z Wave gateway comparison http aeotec com z wave gateways list...

Страница 2: ...seconds Health Test Press and hold for 15 seconds Factory Reset Important safety information Please read this and other device guides carefully Failure to follow the recommendations set forth by Aeote...

Страница 3: ...your TriSensor into a Z Wave Network With it powered on it s now time to add your TriSensor to a Z Wave network To pair TriSensor you are not limited to only the Z Stick or Minimote You may use any Z...

Страница 4: ...ill deactivate without flashing white or green 3 You can test if your TriSensor has been successfully included into your Z Wave network by pressing its Action Button If you press the button and your s...

Страница 5: ...eing false motion tracking run trial and error to determine the best sensitivity from a range of 0 11 by going down 1 sensitivity level after every test first 5 4 3 2 then 1 while setting Parameter 3...

Страница 6: ...suggest you choose the second method using screws to affix the Back Mount Arm which would be more stable 2 After you have completed the affixing of Back Mount Arm you will need to lock TriSensor to t...

Страница 7: ...placement is necessary Recommendation For networks which do not offer a method to display For the battery level of your TriSensor it is recommended that the sensor be tested occasionally to ensure tha...

Страница 8: ...on 1 Remove TriSensors battery cover by unlocking then removing the cover 2 Press and hold TriSensors Action Button until LED turns yellow 5 seconds of holding 3 Release TriSensors button If you were...

Страница 9: ...etwork Your TriSensor can be removed from your Z Wave network at anytime You ll need to use your Z Wave network s main controller to do this and the following instructions tell you how to do this usin...

Страница 10: ...pdesk attachments 6064224662 Monitoring motion When TriSensor detects a motion event it will automatically send a notification report to Group 1 which is usually automatically set to report to your ga...

Страница 11: ...gateways that use the older style of motion reports If you do not see status changes over your motion sensor you must enable this setting Command Class COMMAND_CLASS_SENSOR_BINARY Command SENSOR_BINA...

Страница 12: ...or change to a Z Wave device based on the trigger Sometimes there may be delays if your gateway is already processing other data which can cause 1 2 second delays from time to time How many devices yo...

Страница 13: ...leared DEFAULT SETTING 0 7 Temperature Alarm Setting Group 3 control This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is lar...

Страница 14: ...rature report Parameter SizeValueDescription 12 1 0 Disable Default 1 Red 2 Green 3 Blue 4 Yelllow 5 Pink 6 Cyan 7 Purple 8 Orange 13 Light report LED This setting changes the color of the LED when yo...

Страница 15: ...0 US 1 0 1 1 Value and Description 0 Celcius 1 Fahrenheit 21 Temperature Threshold reporting Change threshold value for change in temperature to induce an automatic report for temperature sensor Scal...

Страница 16: ...22 Light Threshold Report Change threshold value for change in light sensor to induce an automatic report for temperature sensor Scale Lux Parameter SizeValue Description 22 2 0 Disable Threshold Rep...

Страница 17: ...92B29I https www amazon com HDE LX 1010B Digital Luxmeter Display dp B00992B29I This is purely an example the more accurate lux meter you have the better calibration setting you will be able to use 1...

Страница 18: ...29 1 2019 TriSensor user guide Aeotec https aeotec freshdesk com support solutions articles 6000195459 trisensor user guide 18 18...

Отзывы: