18
DC/AC MicroProbe Models K100 and K110
4.4 MODEL K110 OPERATION EXAMPLES
4.4.1 Measuring the DC Component of an (AC+DC) Waveform
(K110)
• Conductor carrying 20.0 mA
DC
+ 15.0 mA
AC
• Voltmeter placed in DC Volts mode
• Voltmeter displays 200.0 mV
15 mA AC
+
20 mA DC
PUSH
DC Zero
200.0
mV
AC
V
DC
V
Figure 11
4.4.2 Measuring the AC Component of an (AC+DC) Waveform
(K110)
• Conductor carrying 20.0 mA
DC
+ 15.0 mA
AC
• Voltmeter placed in AC Volts mode
• Voltmeter displays 150.0 mV
PUSH
DC Zero
150.0
mV
AC
V
DC
V
15 mA AC
+
20 mA DC
Figure 12