ROTARY SWITCH

 

Calibration screw position settings 

 
The calibration will not be changed until the rotary switch reaches the middle of the new 
position. 
 

AEM Lambda Gauge Owners

  

Because the Lambda gauge faceplate is calibrated for (

λ

) and all other calibration 

positions are for AFR (Gasoline), AEM does not recommended changing the controller 
calibration, as instructed above. 
 
Below is the multiplier for calculating the Air Fuel Ratio (AFR) of common fuels from the 
Lambda value. 
 
Gasoline AFR  

=  

Lambda x 14.65 

Methanol AFR  

=  

Lambda x 6.47 

Propane AFR  

=  

Lambda x 15.7 

Ethanol AFR   

=  

Lambda x 9.00 

CNG AFR    

=  

Lambda x 14.5 

11.0

11.5

12.0

12.5

13.0

13.5

14.0

14.5

15.0

15.5

16.0

16.5

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

Analog Voltage (V)

A

ir

/Fu

e

l G

a

s

o

li

n

e

 (A

FR

)

0.75

0.80

0.85

0.90

0.95

1.00

1.05

1.10

La
m

b

d

a

 (

λ

AFR Small Volt Range (P2)

AFR Autronic Emulation (P3)

AFR Nernst Emulation (P4)

AEM GAUGE Default (P0 & P1)

 

Calibration graph of available outputs 

Содержание 30-4100

Страница 1: ...oller AEM Gauge Type UEGO Controller Parts 1 x UEGO Gauge Assembly 1 x UEGO Sensor 1 x O2 Sensor Bung 4 x Butt Connectors 1 x Installation Instruction Replacement O2 Sensor Components 30 2001 UEGO Sen...

Страница 2: ...Cell technology commonly called Narrow Band and sometimes erroneously described as Wide Band This is a very cost effective method that outputs a voltage based on the oxygen content of the gas being sa...

Страница 3: ...he entire operating range Each AEM UEGO sensor is individually calibrated and a resistor integral at the connector body is laser trimmed with this value This process replaces the traditional free air...

Страница 4: ...able Lambda input channel can be done using the Application Notes provided with the EMS If the Application Notes are not readily accessible a current list of AEM Engine Management Systems is illustrat...

Страница 5: ...51 0 47 10 94 4 83 11 72 6 72 10 83 0 62 11 24 4 96 12 05 6 91 11 12 0 78 11 56 5 11 12 39 7 10 11 44 0 94 11 88 5 25 12 73 7 30 11 76 1 09 12 18 5 38 13 05 7 48 12 06 1 25 12 50 5 52 13 40 7 68 12 37...

Страница 6: ...AEM UEGO Gauge shall be connected to Pin 2 RX on the serial port for receiving data Pin 5 GND on the serial port shall be grounded If a standard 9 pin serial cable is to be cut instead the RX wire is...

Страница 7: ...nector UEGO Sensor connector without latch If the UEGO sensor is to be put through a conduit or firewall a 1 05in 26 7mm drill is required Refer to the two diagrams above when reassembling the connect...

Страница 8: ...calibration is desired the AEM calibration can be changed to one of three available The AEM default position is P0 if an AFR Gauge was purchased and P1 if a Lambda Gauge was purchased These settings...

Страница 9: ...instructed above Below is the multiplier for calculating the Air Fuel Ratio AFR of common fuels from the Lambda value Gasoline AFR Lambda x 14 65 Methanol AFR Lambda x 6 47 Propane AFR Lambda x 15 7 E...

Страница 10: ...products will be free from defects in material and workmanship for a period of twelve 12 months from date of the original purchase Products that fail within this 12 month warranty period will be repa...

Отзывы: