AEM 30-4100 Скачать руководство пользователя страница 4

Gauge-Type UEGO Controller Installation 

 

 

RED 

<Power>

 

 

Connect to a switched 10-18 volt power source utilizing a 10A fuse. 

 
BLACK 

<Ground>

   

Connect to a clean power ground. 

 
*WHITE 

<Analog Output><optional hookup>

 

Connects to any Stand Alone ECU unit that accepts a 0-5 volt input. 

 
*BLUE 

<Serial Output><optional hookup>

 

Connects to a RS-232 com port for hyper-terminal data logging. 

 
*optional (see below)

 

 
 

Analog Output 

If the AEM UEGO gauge is to be connected to an AEM EMS, the UEGO gauge’s 
WHITE Analog Output wire shall be connected to an EMS Lambda input. Locating a 
suitable Lambda input channel can be done using the Application Notes provided with 
the EMS. If the Application Notes are not readily accessible, a current list of AEM 
Engine Management Systems is illustrated below.  
 

Lambda input channel locations of current EMS application list ( see EMS 
instructions for ECU connector pictures)

 

 

AEM EMS P/N 

Lambda #1 Pin 

Lambda #2 Pin 

30-1000/1001/1002/1040 D14 

D16 

30-1010/1012/1050/1052 C16 

A23 

30-1020/1060 D7 

D14 

30-1030/30-1070 C13 C14 

30-1100/1101 B47 

B48 

30-1110 1C 

9C 

30-1120/1121/1130 B6  B14 

30-1300 4 

66 

30-1310/1311/1312/1313 76 

75 

30-1400 29 

43 

30-1401 44 

43 

30-1510 C2-31 

C2-33 

30-1600/1601/1602/1603 19 

NA 

30-1610/1611/1612 46  52 
30-1620/1621/1622 29  55 

30-1710 2N 

4J 

30-1720 C3 

D3 

30-1800 C3 

A2 

30-1810 D19 

B17 

Содержание 30-4100

Страница 1: ...oller AEM Gauge Type UEGO Controller Parts 1 x UEGO Gauge Assembly 1 x UEGO Sensor 1 x O2 Sensor Bung 4 x Butt Connectors 1 x Installation Instruction Replacement O2 Sensor Components 30 2001 UEGO Sen...

Страница 2: ...Cell technology commonly called Narrow Band and sometimes erroneously described as Wide Band This is a very cost effective method that outputs a voltage based on the oxygen content of the gas being sa...

Страница 3: ...he entire operating range Each AEM UEGO sensor is individually calibrated and a resistor integral at the connector body is laser trimmed with this value This process replaces the traditional free air...

Страница 4: ...able Lambda input channel can be done using the Application Notes provided with the EMS If the Application Notes are not readily accessible a current list of AEM Engine Management Systems is illustrat...

Страница 5: ...51 0 47 10 94 4 83 11 72 6 72 10 83 0 62 11 24 4 96 12 05 6 91 11 12 0 78 11 56 5 11 12 39 7 10 11 44 0 94 11 88 5 25 12 73 7 30 11 76 1 09 12 18 5 38 13 05 7 48 12 06 1 25 12 50 5 52 13 40 7 68 12 37...

Страница 6: ...AEM UEGO Gauge shall be connected to Pin 2 RX on the serial port for receiving data Pin 5 GND on the serial port shall be grounded If a standard 9 pin serial cable is to be cut instead the RX wire is...

Страница 7: ...nector UEGO Sensor connector without latch If the UEGO sensor is to be put through a conduit or firewall a 1 05in 26 7mm drill is required Refer to the two diagrams above when reassembling the connect...

Страница 8: ...calibration is desired the AEM calibration can be changed to one of three available The AEM default position is P0 if an AFR Gauge was purchased and P1 if a Lambda Gauge was purchased These settings...

Страница 9: ...instructed above Below is the multiplier for calculating the Air Fuel Ratio AFR of common fuels from the Lambda value Gasoline AFR Lambda x 14 65 Methanol AFR Lambda x 6 47 Propane AFR Lambda x 15 7 E...

Страница 10: ...products will be free from defects in material and workmanship for a period of twelve 12 months from date of the original purchase Products that fail within this 12 month warranty period will be repa...

Отзывы: