Installation Instructions for 

30-4100 

Gauge-Type UEGO Controller

 

 

 

 

 

 

AEM Gauge-Type UEGO Controller Parts 

1 x UEGO Gauge Assembly 
1 x UEGO Sensor 
1 x O2 Sensor Bung 
4 x Butt Connectors 
1 x Installation Instruction 

Replacement O2 Sensor Components 

30-2001 UEGO 

Sensor 

35-4005 Mild 

Steel 

Oxygen Sensor Bung (welding required) 

 

 
 

Содержание 30-4100

Страница 1: ...oller AEM Gauge Type UEGO Controller Parts 1 x UEGO Gauge Assembly 1 x UEGO Sensor 1 x O2 Sensor Bung 4 x Butt Connectors 1 x Installation Instruction Replacement O2 Sensor Components 30 2001 UEGO Sen...

Страница 2: ...Cell technology commonly called Narrow Band and sometimes erroneously described as Wide Band This is a very cost effective method that outputs a voltage based on the oxygen content of the gas being sa...

Страница 3: ...he entire operating range Each AEM UEGO sensor is individually calibrated and a resistor integral at the connector body is laser trimmed with this value This process replaces the traditional free air...

Страница 4: ...able Lambda input channel can be done using the Application Notes provided with the EMS If the Application Notes are not readily accessible a current list of AEM Engine Management Systems is illustrat...

Страница 5: ...51 0 47 10 94 4 83 11 72 6 72 10 83 0 62 11 24 4 96 12 05 6 91 11 12 0 78 11 56 5 11 12 39 7 10 11 44 0 94 11 88 5 25 12 73 7 30 11 76 1 09 12 18 5 38 13 05 7 48 12 06 1 25 12 50 5 52 13 40 7 68 12 37...

Страница 6: ...AEM UEGO Gauge shall be connected to Pin 2 RX on the serial port for receiving data Pin 5 GND on the serial port shall be grounded If a standard 9 pin serial cable is to be cut instead the RX wire is...

Страница 7: ...nector UEGO Sensor connector without latch If the UEGO sensor is to be put through a conduit or firewall a 1 05in 26 7mm drill is required Refer to the two diagrams above when reassembling the connect...

Страница 8: ...calibration is desired the AEM calibration can be changed to one of three available The AEM default position is P0 if an AFR Gauge was purchased and P1 if a Lambda Gauge was purchased These settings...

Страница 9: ...instructed above Below is the multiplier for calculating the Air Fuel Ratio AFR of common fuels from the Lambda value Gasoline AFR Lambda x 14 65 Methanol AFR Lambda x 6 47 Propane AFR Lambda x 15 7 E...

Страница 10: ...products will be free from defects in material and workmanship for a period of twelve 12 months from date of the original purchase Products that fail within this 12 month warranty period will be repa...