background image

 

Page 8

 

 

 

 

 

 

WARRANTY 

12 MONTH LIMITED WARRANTY 

 
Advanced  Engine  Management  Inc.  warrants  to  the  consumer  that  all  AEM  High  Performance  products  will  be  free  from  defects  in  material  and 
workmanship  for  a  period  of  twelve  (12)  months  from  date  of  the  original  purchase.  Products  that  fail  within  this  12-month  warranty  period  will  be 
repaired  or  replaced  at  AEM’s  option,  when  determined  by  AEM  that  the  product  failed  due  to  defects  in  material  or  workmanship.  This  warranty  is 
limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be 
responsible  for  special,  incidental  or  consequential  damages  or  cost  incurred  due  to  the  failure  of  this  product.    Warranty  claims  to  AEM  must  be 
transportation  prepaid  and  accompanied  with  dated  proof  of  purchase.  This  warranty  applies  only  to  the  original  purchaser  of  product  and  is  non-
transferable.  All  implied  warranties  shall  be  limited  in  duration  to  the  said  12  month  warranty  period.  Improper  use  or  installation,  accident,  abuse, 
unauthorized  repairs  or  alterations  voids this  warranty.  AEM  disclaims  any  liability for  consequential damages  due  to  breach  of  any  written  or  implied 
warranty  on  all  products  manufactured  by  AEM.  Warranty  returns  will  only  be  accepted  by  AEM  when  accompanied  by  a  valid  Return  Goods 
Authorization (RGA) number.  Product must be received by AEM within 30 days of the date the RGA is issued. 
 
Please  note  that  before  AEM  can  issue  an  RGA  for  any  product,  it  is  first  necessary  for  the  installer  or  end  user  to  contact  the  AEM  Performance 
Electronics tech line at 1-800-423-0046 to discuss the problem.  Most issues can be resolved over the phone.  Under no circumstances should a system 
be returned or a RGA requested before the above process transpires. 
 

Need additional help?  Contact the AEM Performance Electronics tech department at  
1-800-423-0046 or [email protected], or visit the AEM Performance Electronics forum at 

http://forum.aempower.com/forum/

 

Содержание 30-3431

Страница 1: ...net adapter is installed the Series 2 EMS will be able to send and receive data on the AEMnet Instructions for configuring the Series 2 EMS to output data are included in this manual Instructions on configuring the Series 2 EMS to receive data from other AEMnet enabled products are contained in the individual product manuals Upon completion of these instructions the Series 2 EMS will be configured...

Страница 2: ... powered by AEMnet The red and black wires will need to be connected when using the Series 2 EMS with devices that are powered by AEMnet such as the Dyno Shaft see individual instructions for details The AEMnet connectors are shown below in figure 1 See table 1 for the AEMnet connection pinout Figure 1 AEMnet connectors wire entry view AEMnet Connector Series 2 EMS Connector Pin 1 White CAN1H Pin ...

Страница 3: ...lly pry white plastic retainer using both slots in the retainer so it disengages vertically about 1mm as shown in figures 2 and 3 please note some connectors may have a lock opposite to the wires in between the pins these can be removed simply using a pair of needle nose pliers Figure 2 Pry in these areas Figure 3 Lock that has to move up 1mm ...

Страница 4: ...ying on the plastic tabs that secure the pin in the plastic connector while gently pulling on the wire at the same time as shown in figures 4 and 5 Figure 4 Pry this tab up with the screwdriver or paper clip to release pin Figure 5 While prying tab gently pull wire back ...

Страница 5: ...R HARNESS 4 Table 2 below lists the corresponding CAN1L and CAN1H pin locations for each Series 2 EMS CAN1L Green wire CAN1H White wire EMS Adapter p n LOCATION LOCATION 30 6040 30 3431 A22 C2 30 6300 30 3434 75 13 Table 2 CAN1L and CAN1H pin locations Figures 7 and 8 below show the connectors for each Series 2 EMS Figure 7 Wire side view of pinout for 6040 EMS Figure 8 Wire side view of pinout fo...

Страница 6: ...NL and CANH pins into the receptacle of the plug and push in until it clicks as shown in figure 9 Figure 9 Pushing pin into ECU plug 6 Push the pin lock back into place until it is flush with the ECU plug as shown in figure 10 Figure 10 Ensure pin lock is relocked ...

Страница 7: ...ware and later To activate the AEMnet data stream open AEMTuner and go to Wizards Setup Wizard and select the AEMnet Data Stream See figure 11 below Figure 11 Selecting the AEMnet Datastream With the AEMnet enabled the Series 2 EMS broadcasts information as shown below in figure 12 Figure 12 AEMnet Data ...

Страница 8: ...t and is non transferable All implied warranties shall be limited in duration to the said 12 month warranty period Improper use or installation accident abuse unauthorized repairs or alterations voids this warranty AEM disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by AEM Warranty returns will only be accepted by AEM ...

Отзывы: