AEI DK-9680 Series Скачать руководство пользователя страница 8

SPECIFICATIONS

!
!
!

!

!

!
!
!
!

!

Operation Voltage

Code Combinations

A)

Duress Output

Dimensions

Weight

:

Single User Mode --- 10,000 for each User Code

(DK-9880) -- 117(W)mm X 21(D)mm X 117(H)mm,

Slim Plastic Case

(DK-9680) -- 155g net
(DK-9880) -- 130g net

Specifications are subject to change for modification without notice

: 12V AC/DC Nominal , 10-14VAC or 12-16VDC
: Version ) 15-150mA; Version ) 15-110mA; Version ) 15-80mA
:

Single User Mode

- User Code 1, 2 & 3 (Fixed to 4 Digits)
- Master Code (Fixed to 4 Digits)
- Duress Code (Fixed to 4 Digits)
- Accelerated Code (2 Digits)
Multi User Mode
- User Codes in Group 1 - 100 Users (4-8 Digits)
- User Codes in Group 2 - 10 Users (4-8 Digits)
- User Codes in Group 3 - 10 Users (4-8 Digits)
- Master Code (4-8 Digits)
- Super User Code (4-8 digits Plus Output Number)
- Duress Codes (4-8 Digits)
- Accelerated Codes (2 Digits)

Multi User Mode ----- 111,110,000 for each User Code

: Output 1 -- 5A / 30VDC Max, N.C. & N.O. Dry Contacts,

Other Outputs -- 1A / 30VDC Max. N.C. & N.O. Dry Contacts (or NPN open

collector output)

: 100mA Sink / 12VDC Maximum, Open Collector switches to ground (-)
: 10 seconds, auto refresh
: 30 seconds, auto refresh
: Master Unit -- 120(W)mm X 87(D)mm X 32.5(H)mm

Keypad Unit: (DK-9680) -- 84(W)mm X 41(D)mm X 129(H)mm,

Weatherproof Plastic Case

: Master Unit -- 200g net

Keypad Unit :

A dry contact means that no electricity was connected to it. It is prepared for free connections. Usually the relay
output contacts provided in a keypad system are dry contacts.

Stands for Normally Closed, the contact is closed circuit at normal status. It is open circuit when activated.

Stands for Normally Open, the contact is open circuit at normal status. It is closed circuit when activated.

An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground similar to an N.O.
relay contact referring to ground. The transistor is normally OFF, and its output switches to ground (-) when
activates. The open collector transistor can only provide switching function for small power but it is usually
good enough for controlling of an alarm system.

Current Drain

A

B

C

Operation Codes Available

A)

B)

B)

Relay Output Contacts

Digit Entry Allowable Time
Code Entry Allowable Time

DRY CONTACT

N.C.

N.O.

TRANSISTOR OPEN COLLECTOR OUTPUT

APPENDIX

!

!

!

!

15

TYPICAL APPLICATION

Output 1:
Output 2:
Output 3:

Door Strike
Alarm Control
Auxiliary Security or Access Control

* Please consult your alarm / security system manual for the selection of N.C. or N.O. for the system ON-OFF

control. For those Open Collector Outputs at the DK-9680B / DK-9880B and DK-9680C / DK-9880C, please
consider them as N.O. output contacts referring to (-) ground.

RED LED

GREEN LED

FOR FREE CONNECTIONS

M A I N S

K E Y

A R M E D

L O C K

DOOR
B E L L

1

2

3

4

5

6

7

8

9

0

#

REMOTE KEYPAD

(inside the premises)

ALARM SYSTEM

AUXILIARY SYSTEM

OUTPUT 2

OUTPUT 3

OUTPUT 1

EGRESS

BUTTON

(inside the premises)

N.O.

12V DC

ELECTRIC

LATCH

MAGNETIC SWITCH

MC-01

N.C.

DOOR SENSING

(DK-9880)

or

(DK-9680 -- outside the premises)

12V AC/DC

POWER SUPPLY

DK-9680A /

DK-9880A

16

SINCE 1979

AEI ADVANCED ELECTRONICS INDUSTRY LTD.

#

Содержание DK-9680 Series

Страница 1: ...controlled by output 1 The circuit is open when the door is open It initiates the following functions 1 When the door is FORCED OPEN the door is opened without the use of a valid code or the EGRESS b...

Страница 2: ...T CCESS TO ROGRAMMING 3 STATUS 1 In programming mode 2 Successful key entry 3 Successful code entry 4 Unsuccessful code entry 5 DAP jumper not replaced 6 Standby mode TONES 1 Beep 2 Beeps 5 Beeps Cont...

Страница 3: ...ary Mode 601 Output 3 is 1 Second Momentary Mode 70 After 10 Successive False Code The Keypad Locks During 30 Seconds 80 Door Force Open Alarm Detection is Disabled 90 The Door Open Too long Timer is...

Страница 4: ...rm enabled k Set the allowable time for door left open for 60 seconds before triggering of the door Open Too Long alarm A SINGLE USER MODE OPERATION An Example 1 Re uirement 8 2 Programming NOTE a Pre...

Страница 5: ...door that is equipped with and leave it open for more than 60 seconds the programmed time The alarm starts Close the door the alarm stops automatically This feature reminds the owner to close the door...

Страница 6: ...ted Code is Output 3 starts Output 3 stops Output 3 starts Output 3 stops 0321 9270 22898 3289 1 3289 2 3289 3 31223 53221 92 9270 22 22898 User Codes of Group 1 The Corresponding Duress Codes 9270 92...

Страница 7: ...the programming mode by press the key E DELETE USER MULTI USER MODE 1 2 3 13 CONNECTING THE REMOTE KEYPAD UNIT S TO THE MASTER UNIT THE TAMPER SWITCH OF THE REMOTE KEYPAD UNIT The basic DK 9680 DK 98...

Страница 8: ...contacts Stands for Normally Closed the contact is closed circuit at normal status It is open circuit when activated Stands for Normally Open the contact is open circuit at normal status It is closed...

Отзывы: