SET THE SYSTEM TO SINGLE USER MODE

SET THE SYSTEM TO MULTI-USER MODE

REFRESH THE SYSTEM

You are required to decide the keypad for Single User or Multi-User Mode in operation. The system can be set for

with the command code "

" and stay in that mode unless the system is refreshed for other

mode.

he system can be set for

with the command code "

" and stay in that mode unless the

system is refreshed for other mode.

A system was set to

It is possible to change it to

; or vice versa. Just refresh

the system with the above operation command codes.

A refreshed keypad will reset itself as a fresh unit with the Default Values.

Make sure all the

and

are set to

after the system is refreshed for Single

User Mode operation. Otherwise, code entry will not be successful.

It is necessary to change the Master Code to 4 digits first (if it was more than 4 digits in Multi Users Mode)
before refreshing from Multi User Mode to Single User Mode.

The system takes approximate 2 to 3 seconds to refresh itself for new operation mode after the refresh code is
entered. DO NOT enter any code during the system is being refreshed until the 2 confirmation beeps are heard.

Single User Mode

8900

MASTER CODE

Single User Mode

Multi User Mode

8901

MASTER CODE

Multi-User Mode

Single User Mode.

Multi-User Mode

All the programmed data that saved

previously are cleared except the Master Code.

IMPORTANT NOTES:
1)

User Codes

Master Code

4 Digits

2)

3)

(wait 2-3 seconds until the confirmation beeps are heard)

(wait 2-3 seconds until the confirmation beeps are heard)

T

-- CHANGE OF OPERATION MODE

q

* 8900 # --------

* 8901 #

PROGRAM AND USE THE KEYPAD

-- OPERATION

Once the operation mode is selected - Single User or Multi Users, all the three outputs will operate with that mode.

-- Set the following data into the system:

a) Single User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set User Code 1 in 8321
d) Set User Code 2 in 6854
e) Set User Code 3 in 9270
f ) Set Output 1 in Momentary Mode, 1 second
g) Set Output 2 in Start / Stop Mode without accelerated code
h) Set Output 3 in Start / Stop Mode with accelerated code
i ) Set the keypad to lock itself during 15 minutes after 10 successive false codes
j ) Set the keypad with door Forced-Open-Alarm enabled
k ) Set the allowable time for door left open for 60 seconds before triggering of the door Open-Too-Long

alarm

A) SINGLE USER MODE OPERATION

-- An Example

1) Re uirement

8

2) Programming

NOTE:

a)

Press

is not

required.

b)

Duress Code

User Code 1 of Two units

For example:

NOTE:

-- Set the above requirement into the keypad:

---------------- Enter to programming mode with the factory-set Master Code

a) **Enter the Single User Mode Command Code "8900" may not be necessary if the keypad was

already in Single User Mode.

b) In case of wrong entry during programming, cancel it with

key, or, wait 10 seconds, then re-

enter.

To command the output 1, 2 & 3, enter the corresponding codes into the keypad.

The

does not need to program. The keypad determines it automatically by increasing the

first digit of the

.

The User Code 1 is "1234", then the Duress Code is "3234"; or the User Code 1 is
"8321", then the Duress Code is "0321".

To command the Duress Function, enter the Duress Code.

i) The Duress Code has double actions. It activates the Duress Output and at the same time activates

the Output 1 as like the User Code 1. The Duress Code can always activates or deactivates (in Start
/ Stop mode) Output 1, but cannot deactivate (reset) the Duress Output. ONLY the User Code 1 can
deactivate (reset) the Duress Output.

ii) All alarms will be stopped, including the door forced-open-alarm and the door open-too-long alarm,

when Duress function is in operation.

0000 *
8900 #
0 3289 #
1 8321 #
2 6854 #
3 9270 #
40 1 #
51 #
62 #
72 10 #

81 #
9 60 #
*

8321
6854
9270

0321

---------------- System has been set for Single User Mode**

------------ 3289 has been saved as the new Personal Master Code
------------ 8321 has been saved as User Code 1, with Duress

Alarm OFF Code functions

------------ 6854 has been saved as User Code 2
------------ 9270 has been saved as User Code 3

---------------- Output 1 has been set in Momentary Mode, 1 second

-------------------- Output 2 has been set in Start / Stop Mode without accelerated code
-------------------- Output 3 has been set in Start / Stop Mode with accelerated code

-------------- The keypad has been set to lock during 15 minutes after 10 successive false

codes

-------------------- The keypad has been set with door Forced-Open-Alarm enabled

---------------- The keypad has been set with 60 seconds allowable time for door left open

--------------------------- Keypad exits programming mode. All the data above are saved and ready for use

-- Taking the data programmed above as reference

----------------- Output 1 activates for 1 second
----------------- Output 2 starts (or stops)
----------------- Output 3 starts (or stops)

----------------- Duress output activates (output switches to ground) & Output 1 activates for 1

second

&

3) Operate The Keypad

#

#

Содержание DK-9680 Series

Страница 1: ...controlled by output 1 The circuit is open when the door is open It initiates the following functions 1 When the door is FORCED OPEN the door is opened without the use of a valid code or the EGRESS b...

Страница 2: ...T CCESS TO ROGRAMMING 3 STATUS 1 In programming mode 2 Successful key entry 3 Successful code entry 4 Unsuccessful code entry 5 DAP jumper not replaced 6 Standby mode TONES 1 Beep 2 Beeps 5 Beeps Cont...

Страница 3: ...ary Mode 601 Output 3 is 1 Second Momentary Mode 70 After 10 Successive False Code The Keypad Locks During 30 Seconds 80 Door Force Open Alarm Detection is Disabled 90 The Door Open Too long Timer is...

Страница 4: ...rm enabled k Set the allowable time for door left open for 60 seconds before triggering of the door Open Too Long alarm A SINGLE USER MODE OPERATION An Example 1 Re uirement 8 2 Programming NOTE a Pre...

Страница 5: ...door that is equipped with and leave it open for more than 60 seconds the programmed time The alarm starts Close the door the alarm stops automatically This feature reminds the owner to close the door...

Страница 6: ...ted Code is Output 3 starts Output 3 stops Output 3 starts Output 3 stops 0321 9270 22898 3289 1 3289 2 3289 3 31223 53221 92 9270 22 22898 User Codes of Group 1 The Corresponding Duress Codes 9270 92...

Страница 7: ...the programming mode by press the key E DELETE USER MULTI USER MODE 1 2 3 13 CONNECTING THE REMOTE KEYPAD UNIT S TO THE MASTER UNIT THE TAMPER SWITCH OF THE REMOTE KEYPAD UNIT The basic DK 9680 DK 98...

Страница 8: ...contacts Stands for Normally Closed the contact is closed circuit at normal status It is open circuit when activated Stands for Normally Open the contact is open circuit at normal status It is closed...

Отзывы: