c)
Accelerated Code
First Two Digits
activate
d)
Safety
1) Re uirement
The
is the
of the User Code. If the User Code 1, 2 or 3 has been
programmed in Start/Stop mode with Accelerated Code, it is possible to
the corresponding
Output 1, 2 or 3 with only the First Two Digits of the User Code. Deactivating of the corresponding
Output 1, 2 or 3 always requires the composition of its own Complete User Code.
----------------- Output 3 starts
---------------- Output 3 stops
Try to put some random false codes to the keypad to test its
. The keypad considers 4 digits as
one code and it generates 5 beeps for each unsuccessful code entry. The keypad locks itself during 15
minutes after 10 successive false codes are entered. Normal operation will be resumed after 15 minutes
expired, or, it can be reset with the Master Code during the locking period.
----------- Locking is reset and keypad resumes normal operation
----------------- Alarm stops
-- Set the following data into the system:
a) Multi-User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set 1st User Code of Group 1 in 8321
d) Set 2nd User Code of Group 1 in 11223
e) Set 3rd User Code of Group 1 in 33221
f ) Set 1st User Code of Group 2 in 6854
g) Set 2nd User Code of Group 2 in 54321
h) Set 1st User Code of Group 3 in 9270
i ) Set 2nd User Code of Group 3 in 22898
j ) Set Output 1 in Momentary Mode, 1 second
k) Set Output 2 in Start / Stop Mode without accelerated code
l ) Set Output 3 in Start / Stop Mode with accelerated code
m) Set the keypad to lock itself during 15 minutes after 10 successive false codes
n) Set the keypad with door Forced-Open-Alarm enabled
o) Set the allowable time for door left open for 60 seconds before triggering of the door Open-Too-Long
alarm
In this example, Output 3 has been programmed in Start / Stop Mode with Accelerated Code.
The Complete Code of Code 3:
The Accelerated Code of Code 3:
In this example, the keypad has been programmed with
enabled. Try to open
the door that is equipped with
, without the use of
or the
.
The alarm will activate instantly for 60 seconds. The alarm can be stopped by User Code 1 before the
end of the alarm time.
The testing may not be feasible if the door is locked. It is necessary to un-lock the door with the
mechanical key before testing.
The
has been enabled in programming. Try to command Output 1 with
or the
. Open the door that is equipped with
, and leave it open for
more than 60 seconds (the programmed time). The alarm starts. Close the door, the alarm stops
automatically. This feature reminds the owner to close the door in case it is stuck.
The keypad incorporates
. To activate the door chime, just simply press the
key.
e)
Door Forced-Open-Alarm
Door Sensing Switch
Code 1
Egress Button
NOTE:
f)
Door Open-Too-Long Alarm
Code
1
Egress Button
Door Sensing Switch
g)
Door Chime
BELL
9270
92
92 #
9270
3289 #
8321
B) MULTI-USER MODE OPERATION
-- An Example
q
9
2) Programming
NOTE:
3) Operate The Keypad
a)
b)
-- Set the above requirement into the keypad:
-------------------------- Enter to programming mode with the factory-set Master Code
------------------------- System has been set for Multi User Mode**
-------------------- 3289 has been saved as the new Personal Master Code
Super User
Code
--------------- 8321 has been saved as the 1st User Code of Group 1 with Duress
Alarm OFF Code functions
------------- 11223 has been saved as the 2nd User Code of Group 1 with Duress
Alarm OFF Code functions
------------- 33221 has been saved as the 3rd User Code of Group 1 with Duress
Alarm OFF Code functions
----------------- 6854 has been saved as the 1st User Code of Group 2
--------------- 54321 has been saved as the 2nd User Code of Group 2
----------------- 9270 has been saved as the 1st User Code of Group 3
--------------- 22898 has been saved as the 2nd User Code of Group 3
------------------------- Output 1 has been set in Momentary Mode, 1 second
----------------------------- Output 2 has been set in Start / Stop Mode without accelerated code
----------------------------- Output 3 has been set in Start / Stop Mode with accelerated code
----------------------- The keypad has been set to lock during 15 minutes after 10 successive
false codes
----------------------------- The keypad has been set with door Forced-Open-Alarm enabled
------------------------- The keypad has been set with 60 seconds allowable time for door left
open
------------------------------------ Keypad exits programming mode. All the data above are saved and ready
for use
a) **Enter the Multi User Mode Command Code "8901" may not be necessary if the keypad was
already in Multi User Mode.
b) In case of wrong entry during programming, cancel it with
key, or, wait 10 seconds, then re-
enter.
-- Taking the data programmed above as reference
To command the output 1, enter any one of the User Codes in Group 1 into the keypad and validate via
the
key
------------ Output 1 activates for 1 second
---------- Output 1 activates for 1 second
---------- Output 1 activates for 1 second
To command the output 2, enter any one of the User Codes in Group 2 into the keypad and validate via
the
key
------------ Output 2 starts (or stops)
---------- Output 2 starts (or stops)
0000 *
8901 #
0 3289 #
1 01 8321 #
1 02 11223 #
1 03 33221 #
2 1 6854 #
2 2 54321 #
3 1 9270 #
3 2 22898 #
40 1 #
51 #
62 #
72 10 #
81 #
9 60 #
*
8321 #
11223 #
33221 #
6854 #
54321 #
&
&
&
&
#
#
#
10