![Aegis M-PA UHF Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/aegis/m-pa-uhf/m-pa-uhf_service-manual_2860379013.webp)
LBI-33057
13
Table 5 - General Troubleshooting
SYMPTOM
POSSIBLE CAUSES
Completely inoperative (no audio and no LCD in-
dication)
1. Dead Battery Pack.
2. Fuse blown: Check radio fuse in Battery Plate.
3. Control Board problem: See LBI-39157.
At power up, radio beeps:
a. twice (once in addition to power up beep)
b. continuously at a 2 Hz rate
c. continuously at a 2 Hz rate and "NO LOCK" is
displayed
1a. Weak Battery Pack
1b. Unit is not programmed: Program radio.
1c. Synthesizer is not locked: Check LOCK DET line, synthesizer
loading and VCO tuning voltage.
At power up, display:
a. flashes "PERS ERR"
b. flashes all segments and the radio beeps.
1a. EEPROM problem on Control Board: See LBI-39157.
1b. Interprocessor communication failure on Control Board: See
LBI-39157.
Receiver inoperative or weak(clear mode).
1. Squelch levels programmed too high: Press Monitor Button to
disable squelch.
2. Channel Guard or Type 99 Enabled: See Operator's Manual.
3. Defective antenna.
4. RF Board problem: Troubleshoot Rear Cover Assembly.
Transmitter inoperative or low range.
1. Power levels programmed low: Check RF output and reprogram
unit if necessary.
2. Weak battery. Note "BAT" flag.
3. Defective antenna
4. RF Board problem: Troubleshoot Rear Cover Assembly.
TX and RX inoperative on some channels only
1. Programming incorrect: Reprogram unit.
2. Synthesizer problem (VCO or prescaler): Check LOCK DET
line (high = lock), VCO tuning voltage and modulas control
line.
3. EEPROM Problem: Troubleshoot Control Board.
TX and RX inoperative on all channels
1. Programming incorrect: Reprogram unit.
2. Synthesizer problem: Check LOCK DET line (high = lock),
VCO tuning voltage and modulas control line.
3. Control Board problem: See LBI-39157.
4. Check SW1, and the low pass filter circuit on the RF Board
Trunk Mode Problems (trunked radios only)
1. Modem circuitry problem: Check U19 and associated circuitry
on Control Board.
2. Low speed data problem: Troubleshoot the related encode or
decode circuitry on the Control Board
Aegis Mode Problems
1. Verify outside addresses and data polarity.
2. If optionally equipped for encryption, verify correct keys are
loaded and selected.
3. Verify CUE codes.
4. Problem on Control Board with Aegis circuitry.
5. See "Trunked Mode Problems" above.