 EL-RG-4K

Medical & Pharmacy Refrigerator

USER MANUAL

1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA

Tel:

 1-800-796-2344 / 

Fax:

 732 879 0248

 WWW.

AEGIS

FRIDGE

.COM

1.5 Power Supply 

•  The Medical Refrigerator uses a three-pin plug which must be well grounded. Never ground the Medical 

Refrigerator through a gas pipe, tap water pipe OR the grounded wire of single-phase power supply etc. Never 

share same circuit with other appliances. Before plugging in your Medical Refrigerator for the first time make 

sure the power cable is free from damage and check that your voltage corresponds to that on the serial plate.

•  Once plugged in the display will show the temperature inside the Medical Refrigerator and the compressor 

will run late on (the indicator light of cooling will be on at the same time ). This temperature is the actual 
temperature recorded by the probes inside the Medical Refrigerator and as the fridge cools to the set point 
(factory set at 4

o

C/39

o

F) so the number on the display will descend accordingly. If power is cut off, wait for at 

least 5 minutes before plugging the unit in again to avoid damaging the compressor.

•  Front panel display
•  Remote alarm connector
•  Light switch
•  Door switch
•  Door
•  LED light
•  Shelves
•  Fan
•  Adjustable leg
•  Cable port

3.Operation

This product is designed to operate at a recommended ambient temperature not more than 38℃.

3.1 Access to power

•  Close the door of the appliance.

3.2 Setting Temperature

•  Press down to decrease the set temperature.
•  Press up to increase the set temperature.

3.3 Turn on/off the light

The light will turn on while the door is opened and will turn off while the closed.
If you want to turn on the light while you do not open the door, you can turn on the switch.

2. Product description

Содержание ECS-180neo

Страница 1: ...switch ON Cabinet door open OFF Cabinet door close 3 PARAMETER LIST Menu Functions Setting range Default Unit Common user menu St Temperature set value Upper limit Lower Limit 4 C C F Po Administrator...

Страница 2: ...lays the code St press the key display the code Po then press Set key display 00 at this time press or to input the password of administrator menu Press Set key again to confirm the password input and...

Страница 3: ...safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision CAUTION Environmental Protection...

Страница 4: ...r air entry by placing object up against the cabinet Please close attention when used by or near children infirm persons Ensure adequate ventilation Do not probe any openings Do not touch any moving p...

Страница 5: ...The power supply flex exits the Medical Refrigerator at the bottom right hand side as viewed from the front For ease of access the flex should be retrieved prior to positioning the Medical Refrigerato...

Страница 6: ...be on at the same time This temperature is the actual temperature recorded by the probes inside the Medical Refrigerator and as the fridge cools to the set point factory set at 4o C 39o F so the numb...

Страница 7: ...pline Fault Possible Cause Action The appliance is not working The unit is plugged in correctly Check the unit is plugged in correctly Plug or lead is damaged Call Our agent or qualified technician Po...