Aegis ECS-180neo Скачать руководство пользователя страница 2

Operation and display panel

Wiring diagram   Refer to the actual product.

4. KEYS DESCRIPTION

Keys

Function

Button action

Set

Enter the status of parameter setting

Pressing the keys for 3s

Switch between menu and parameter

Press the response

Adjust menu and parameters

Pressing the keys for 3s

Open/close light

(only valid for the model with light control)

Press the response

Upload the data to copy card

Pressing the keys for 3s

Adjust menu and parameters

Press the response

Download the copy card

Pressing the keys for 3s

View evaporator sensor temperature

Press the response

Exit from parameter setting

Press the response

6. INTERNAL ALARM

Alarm

code

Alarm reason

E1

Cabinet temperature sensor failure

E2

Evaporator sensor failure

E3

Condenser sensor failure

cH

Condenser high temperature alarm

rH

Cabinet high temperature alarm

rL

Cabinet low temperature alarm

Er

Copy card programming failure

EP

Inconsistent data between copy card and controller, programming failure

Temperature Controller

ECS-180neo

USER MANUAL

1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA

Tel:

 1-800-796-2344 / 

Fax:

 732 879 0248

 WWW.

AEGIS

FRIDGE

.COM

5. KEYS OPERATION

In the status of temperature measuring and controlling, press Set key for three 

seconds to enter user menu, it displays the code St, then press Set key again, display 

the value of St. It could be modified by pressing the key      or    .  

When it displays the code St, press the key      display the code Po, then press Set key, 

display 00,  at this time, press      or     to input the password of administrator menu. 

Press Set key again to confirm the password input, and the controller will 

automatically verify the correctness of password. When it passes, it could select 

parameter items St, Po, C1, C2……U1 (that is, any parameter items both in the 

administrator menu and user manuals) by pressing the key     or    . Or else, only the 

parameters items St and Po available, others could not be displayed. 

When the parameter item is selected, press Set key to enter to the setting of the current 

item, press     or     to modify the value, and then press Set key to return to the menu. 

Under the status of parameter setting, press       key or no key operation within 30s, it 

will exit from parameter setting and automatically save the current parameter value.

7. SAFETY RULES

Danger

Strictly distinguish the power wire, relay output, sensor down-lead and 

data line, and the relay could not be overloaded.

Prohibit connecting the wire terminals without electricity cut-off.

Warning Prohibit using this unit under the environment of over damp, high temp., 

strong electromagnetism interference or strong corrosion.

Notice

The power supply should conform to the voltage value indicated in the 

instruction, and make sure a steady power supply.

To avoid the possible interference, the sensor down-lead/data line and 

power wire should be kept in a proper distance. 

 When evaporator sensor is installed, the sensor should be well connected 

with the copper tube which is 5cm away from evaporator inlet.

Содержание ECS-180neo

Страница 1: ...switch ON Cabinet door open OFF Cabinet door close 3 PARAMETER LIST Menu Functions Setting range Default Unit Common user menu St Temperature set value Upper limit Lower Limit 4 C C F Po Administrator...

Страница 2: ...lays the code St press the key display the code Po then press Set key display 00 at this time press or to input the password of administrator menu Press Set key again to confirm the password input and...

Страница 3: ...safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision CAUTION Environmental Protection...

Страница 4: ...r air entry by placing object up against the cabinet Please close attention when used by or near children infirm persons Ensure adequate ventilation Do not probe any openings Do not touch any moving p...

Страница 5: ...The power supply flex exits the Medical Refrigerator at the bottom right hand side as viewed from the front For ease of access the flex should be retrieved prior to positioning the Medical Refrigerato...

Страница 6: ...be on at the same time This temperature is the actual temperature recorded by the probes inside the Medical Refrigerator and as the fridge cools to the set point factory set at 4o C 39o F so the numb...

Страница 7: ...pline Fault Possible Cause Action The appliance is not working The unit is plugged in correctly Check the unit is plugged in correctly Plug or lead is damaged Call Our agent or qualified technician Po...

Страница 8: ...4M EL RG 4K Medical Pharmacy Refrigerator USER MANUAL 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA Tel 1 800 796 2344 Fax 732 879 0248 WWW AEGISFRIDGE COM Certificate of Quality Checker Checker Che...

Отзывы: