Operation and display panel
Wiring diagram Refer to the actual product.
4. KEYS DESCRIPTION
Keys
Function
Button action
Set
Enter the status of parameter setting
Pressing the keys for 3s
Switch between menu and parameter
Press the response
Adjust menu and parameters
Pressing the keys for 3s
Open/close light
(only valid for the model with light control)
Press the response
Upload the data to copy card
Pressing the keys for 3s
Adjust menu and parameters
Press the response
Download the copy card
Pressing the keys for 3s
View evaporator sensor temperature
Press the response
Exit from parameter setting
Press the response
6. INTERNAL ALARM
Alarm
code
Alarm reason
E1
Cabinet temperature sensor failure
E2
Evaporator sensor failure
E3
Condenser sensor failure
cH
Condenser high temperature alarm
rH
Cabinet high temperature alarm
rL
Cabinet low temperature alarm
Er
Copy card programming failure
EP
Inconsistent data between copy card and controller, programming failure
Temperature Controller
ECS-180neo
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel:
1-800-796-2344 /
Fax:
732 879 0248
WWW.
AEGIS
FRIDGE
.COM
5. KEYS OPERATION
In the status of temperature measuring and controlling, press Set key for three
seconds to enter user menu, it displays the code St, then press Set key again, display
the value of St. It could be modified by pressing the key or .
When it displays the code St, press the key display the code Po, then press Set key,
display 00, at this time, press or to input the password of administrator menu.
Press Set key again to confirm the password input, and the controller will
automatically verify the correctness of password. When it passes, it could select
parameter items St, Po, C1, C2……U1 (that is, any parameter items both in the
administrator menu and user manuals) by pressing the key or . Or else, only the
parameters items St and Po available, others could not be displayed.
When the parameter item is selected, press Set key to enter to the setting of the current
item, press or to modify the value, and then press Set key to return to the menu.
Under the status of parameter setting, press key or no key operation within 30s, it
will exit from parameter setting and automatically save the current parameter value.
7. SAFETY RULES
Danger
Strictly distinguish the power wire, relay output, sensor down-lead and
data line, and the relay could not be overloaded.
Prohibit connecting the wire terminals without electricity cut-off.
Warning Prohibit using this unit under the environment of over damp, high temp.,
strong electromagnetism interference or strong corrosion.
Notice
The power supply should conform to the voltage value indicated in the
instruction, and make sure a steady power supply.
To avoid the possible interference, the sensor down-lead/data line and
power wire should be kept in a proper distance.
When evaporator sensor is installed, the sensor should be well connected
with the copper tube which is 5cm away from evaporator inlet.