background image

INTRODUCTION

Thank you for purchasing an Aegis Battery product. It is a wise choice. You are kindly advised to

read and familiarize with the contents of this manual prior to use as failure to do so may result in

degraded battery characteristics.

The model you have purchased is the

ALF-048100A 48V, 100Ah

rated LiFePO4 (LFP) Battery

featuring enhanced safety, non-toxicity, higher performance and extended service life as

compared with traditional lead-type batteries including but not limited to SLA, AGL and GEL. This

battery was assembled in our ISO 9001 Certified production facilities and as such you can expect

performance and consistency from this product and every other product you may be using or

have used.

CONTENTS

+ Aegis Energies (dba: Aegis Battery) LiFePO4 (LFP) Battery Pack (ALF-048100A)

+ Model Compatible Charger (If an optional Charger was purchased)

+ 1 Copy User Manual

SPECIFICATIONS*

Battery Type

ABS Case

Voltage (V)

48V

Capacity (Ah)

100Ah

Energy Stored (Wh)

4800 Watt-Hours

Weight

88.9 lbs. (40.0kg)

Dimension (L x W x H)

520 mm x 260 mm x 220 mm

20.8 in. x 10.2 in. x 8.6 in.

Normal Charge Voltage

58.4V

Normal Charge Current

20.0 Amps

Normal Battery Cutoff Voltage

36.8V

Nominal Continuous Discharge Current

50.0 Amps

Maximum Continuous Discharge Current

100.0 Amps

Maximum Peak Pulse Discharge Current

200.0 Amps (

2 Seconds

)

Charge Temperature

0°C to 45°C

Discharge Temperature

-20°C to 60°C

Operating/Storage Humidity

60±25%R.H

Automatic Battery Protection

Module/System

Low /Over Voltage Disconnect

Cell Balancing

Short Circuit Protection

Reverse Polarity Protection

CHARGING

PRIOR TO INITIAL USE, ENSURE BATTERY HAS TAKEN FULL CHARGE AND IS IN A FULLY

CHARGED STATE. OUR BATTERIES MAY NOT BE SHIPPED FULLY CHARGED!

MAKE SURE THE CHARGER’S INDICATOR LIGHT HAS TURNED

GREEN

AND WAIT FOR 30

MIN. ELAPSE BEFORE UNPLUGGING, CHARGE TIME VARIES FROM MODEL TO MODEL!

When charging your battery, please follow the provided sequence below:

1. Attach Battery Charging Connector to Charger (This will vary depending on your selected

model and configuration of battery).

2. Attach Charger to 110VAC Outlet.

3. When Charging you should observe a

RED

LED Indicator: this indicates that the battery is

currently in the Constant Current (CC) charging phase.

4. Wait for a

GREEN

LED Indicator: this indicates the battery is currently in the Constant Voltage

(CV) charging phase.

5. Wait 30 MINUTES before unplugging the Charger from the 110VAC Outlet

FIRST

and then

disconnecting the Battery from the Charger

SECOND.

DISCHARGING (STANDARD, SERIES/PARALLEL <0.5C DISCHARGE)

1. Make sure your load accepts

48V

nominal voltage.

2. Ensure the connection between the battery and the load can handle the current draw. Please

consult references for the appropriate wire type.

3. The maximum continuous discharge current is

100A

. Please make sure your electrical load

consumes a current

less than100A continuous and maximum 4800 watts of power.

4. The battery outputs steady voltage until little capacity remains, do NOT rely on voltage as an

indicator of remaining capacity, Aegis Battery recommends the usage of an In-Line Watt Meter

for conveyance of accurate battery discharge telemetry.

Series:

Each battery must be charged separately and given a full charge before connecting in

series.

Parallel:

Only connect batteries with equal state of charge in parallel. Also, measure the internal

resistance of each battery and only use batteries with closely matched internal resistance of the

same make, model and batch origin. It is highly recommended that resistors be used to achieve

equal internal resistance between batteries and to add fuse(s) to the circuit for safety reasons.

SAFETY GUIDELINES

Please adhere to the following Safety Guidelines in addition to all disclosed information when

using your battery. Any damage incurred as a result of a failure to adhere to the recommended

usage guidelines as collectively disclosed may result in a partial or complete voiding of the

warranty as provided upon purchase of this battery product.

Additional Safety Guidelines are as

follows.

1. Do not disassemble and/or attempt self-repair.

2. Do not short circuit positive and negative terminals.

3. Do not use lead acid chargers as they will cause damage to internal hardware.

4. Do not dispose in normal refuse bin, recycle this product only at designated facilities.

5. For long term storage, fully charge the battery and then discharge to 50% of the full capacity.

6. Do not leave the battery unattended for more than 6 months or in the presence of children. It

is recommended to charge the battery every three months if it is not used.

7. Do not use the battery in or expose the battery to extreme temperatures.

(

*

For full specifications, please visit

www.aegisbattery.com

)

SPECIFICATIONS*