32
Concern
Potential Cause
Common Solution
Ice dispenser
is jammed.
• Ice has melted and frozen
around auger due to
infrequent use, temperature
fluctuations, and/or power
outages.
• Ice cubes are jammed
between ice maker and
back of ice container.
• Remove ice container, thaw,
and empty the contents.
Clean container, wipe
dry, and replace in proper
position. When new ice is
made, dispenser should
operate.
• Remove ice cubes that are
jamming the dispenser.
Dispenser will not
dispense water.
•
Water filter not seated
properly.
•
Water filter is clogged.
• Household water line valve
is not open.
• Remove and reinstall the
water filter. For Puresource
Ultra II, be sure to rotate it
to the right until it stops and
the grip end is vertical.
•
Replace filter cartridge. Be
sure to rotate it to the right
until it stops and the grip
end is vertical.
• Open household water
line valve. See CONCERN
column AUTOMATIC ICE
MAKER.
Water not cold
enough.
• As warmer tap water goes
through the filter and enters
the water supply system,
the chilled water is pushed
through to the dispenser.
Once the chilled water is used
up, it will take several hours
to bring the freshly replaced
water to a cooler temperature.
• Add ice to cup or container
before dispensing water.
Note: Only first 750 ml are
chilled.
Water has an odd
taste and/or odor.
• Water has not been
dispensed for an extended
period of time.
• Unit not properly connected
to cold water line.
• Draw and discard
10-12 glasses of water
to freshen the supply.
• Connect unit to cold water
line that supplies water
to the kitchen faucet.
Содержание RMB96719CX
Страница 36: ...36 www aeg com 18 NOISES There are some sounds during normal running compressor refrigerant circulation ...
Страница 37: ...37 ENGLISH ...
Страница 71: ...71 DANSK 18 LYDE Der kommer lyde under normal drift kompressor kølekredsløb ...
Страница 72: ...72 www aeg com ...
Страница 107: ...107 SUOMI 18 ÄÄNET Tietynlaiset äänet kuuluvat laitteen normaaliin toimintaan kompressori jäähdytysaineen kierto ...
Страница 108: ...108 www aeg com ...
Страница 143: ...143 NORSK 18 STØY Skapet lager lyder under normal bruk kompressor sirkulering av kjølevæske ...
Страница 144: ...144 www aeg com ...
Страница 179: ...179 SVENSKA 18 LJUD Vissa ljud hörs under normal användning kompressor cirkulation av köldmedel ...
Страница 180: ...180 www aeg com ...
Страница 217: ...217 NEDERLANDS 18 GELUIDEN Tijdens normaal gebruik hoort u geluiden compressor koelmiddelcirculatie ...
Страница 218: ...218 www aeg com ...
Страница 257: ...257 FRANÇAIS ...
Страница 258: ...258 www aeg com ...
Страница 298: ...298 www aeg com ...
Страница 334: ...334 www aeg com ...
Страница 335: ......
Страница 336: ...A10883128 A 322019 www aeg com shop ...