3.3

 

Technical Data 

Type rating

Type rating

Type rating

Type rating    

Protect A 500 LCD  

 

     500 VA / 300 W 

Protect A 700 LCD 

 

     700 VA / 420 W 

Protect A 1200 LCD 

 

     1200 VA / 720 W 

Protect A 1600 LCD 

 

     1600 VA / 960 W 

 
UPS input

UPS input

UPS input

UPS input    

Nominal connection voltage  

      230 Vac 

Voltage range without battery 

      170 Vac to 280 Vac 

Frequency (automatic detection) 

      50 / 60 Hz 

Connection                                                   Non-heating appliance 

connector IEC 320 C 14 

UPS output

UPS output

UPS output

UPS output    

Rated output voltage 

                      230 Vac 

Rated output voltage in  

                      ±10 % 

battery operation 
Frequency in battery operation 

      50 Hz / 60 Hz ± 1 Hz 

Nominal output current 

                      2.2 A (Protect A 500 LCD) 

3.0 A (Protect A 700 LCD) 
5.2 A (Protect A 1200 LCD) 
7.0 A (Protect A 1600 LCD) 

Changeover time in the event  

      2-6 ms (Protect A 500 

of mains failure (typical)                        
LCD and Protect A 700 
LCD) 4-8 ms (Protect A 
1200 LCD and Protect A 
1600 LCD) 

Type of voltage wave 

 

       Modified sine wave 

Connection 

4* IEC outlet (Protect A 
500 LCD/700 LCD)6* IEC 
outlet (Protect A 1200 
LCD/1600 LCD) 

Protection against over- 

                       Yes 

temperature and short circuit 

Содержание Protect A 1200 LCD

Страница 1: ...Protect A 500 LCD Protect A 700 LCD Protect A 1200 LCD Protect A 1600 LCD PROTECTA User Manual ...

Страница 2: ...2 Status Status Status Status Change Change Change Change Date Date Date Date Name Name Name Name 00 Created 29 01 2019 Gortan REVISION ...

Страница 3: ...G PS UPS Protect A LCD from AEG Power Solutions Safety information and operating instructions are included in this manual To ensure correct use of the UPS please read this manual thoroughly before operating it Use this manual properly ...

Страница 4: ...ions when installing the software You can download the software manual and short reference manual at the following site www ups software download com Problem solving Problem solving Problem solving Problem solving Please check the chapter in your manual hardware and software on problem solving If this not solve your problem please contact your reseller for advice Service and Maintenance Service an...

Страница 5: ...1 3 3 Technical Data 14 4 SET UP 17 4 1 Unpacking and Inspection 17 4 2 Installation Site 18 4 3 Front Panel 18 4 4 Back Panel 19 4 5 Display 20 5 INSTALLATION AND INITIAL SETUP 23 5 1 Check 23 5 2 Placement and Storage Conditions 23 5 3 Connect to Utility and Charge 23 5 4 Connect the Loads 24 5 5 Connect 1000Mb Ethernet for Surge Protection 25 5 6 Connect USB Cable 25 5 7 Turn On Off the Unit 25...

Страница 6: ...nstructions comply with the current technical specifications of Protect A at the time of publication The contents do not constitute subject matter of the contract but serve for information purposes only 1 4 Warranty and Liability We reserve the right to alter any specifications given in these operating instructions especially with regard to technical data and operation prior to start up or as a re...

Страница 7: ...Power Solutions GmBH Warstein Belecke Germany All rights reserved This document must not be reproduced either in whole or in part without the express permission of AEG Power Solutions GmBH AEG is a registered trademark used under license from AB Electrolux This pro This pro This pro This product complies with the safety and environmental regulations duct complies with the safety and environmental ...

Страница 8: ... the communication interfaces and connections for telephone lines Important UPS data is monitored permanently and transferred to the computer via USB or the RS232 interface and using the CompuWatch or WinPower software Features of Protect A VI line interactive protection technology Automatic voltage regulation against mains voltage deviations AVR Microprocessor control for high reliability and eff...

Страница 9: ...s filters which provide effective protection against mains voltage peaks and high frequency faults In case of sustained mains under voltage or overvoltage within defined ranges the automatic voltage regulator AVR further stabilises the load voltage As a result voltage fluctuations in the public utility s mains are reduced to a level which is acceptable for the loads This is performed without recou...

Страница 10: ...ically switch back the loads to mains supply The battery charger will then recharge the battery For safety reasons as required by German standards VDE the mains input in the unit will be disconnected by a two pole switch in the event of a mains failure Energy backfeed to the mains and voltage supply to the pins of the mains connector are thus reliably avoided Furthermore additional measures ensure...

Страница 11: ...ollowing pictograms are used in these operating instructions to identify dangers and important information 3 2 Safety Instructions for Protect A This chapter contains important instructions for Protect A These must be followed during assembly operation and maintenance of the uninterruptible power supply and the batteries The UPS is live and the voltage can be dangerous The unit may only be opened ...

Страница 12: ... working in its normal mode Observe the following safety instructions to ensure permanent operational safety of and safe work with the UPS Do not dismantle the UPS The UPS does not contain any parts that require regular maintenance Bear in mind that the warranty will be invalidated if the unit is opened Do not install the unit in direct sunshine or in close proximity of heaters The unit is designe...

Страница 13: ... battery or carry out maintenance work this must be done by or under the supervision of a specialist familiar with batteries and the necessary safety precautions Only authorized Only authorized Only authorized Only authorized persons are allowed in the persons are allowed in the persons are allowed in the persons are allowed in the vicinity of the batteries vicinity of the batteries vicinity of th...

Страница 14: ... output UPS output UPS output UPS output Rated output voltage 230 Vac Rated output voltage in 10 battery operation Frequency in battery operation 50 Hz 60 Hz 1 Hz Nominal output current 2 2 A Protect A 500 LCD 3 0 A Protect A 700 LCD 5 2 A Protect A 1200 LCD 7 0 A Protect A 1600 LCD Changeover time in the event 2 6 ms Protect A 500 of mains failure typical LCD and Protect A 700 LCD 4 8 ms Protect ...

Страница 15: ...aces USB and RS232 Shutdown software For all common operating systems e g Windows Linux Mac Unix FreeBSD Novell Sun General data General data General data General data Inherent noise 1m distance 40 dB A Protect A 500 700 1200 LCD 45 dB A Protect A 1600 LCD Operating temperature range 0 C to 40 C Humidity 0 to 90 without condensation Installation height Up to 1000m at nominal output Housing colour ...

Страница 16: ...ery 0 C to 40 C Conformity CE Directives Directives Directives Directives Protect A product line meets the product standard EN 62040 3 2011 The CE mark on the unit confirms compliance with the EC outline directives for 2014 30 EU EMC guideline and 2014 35 EU Low voltage guideline and in conformity with related standards EN 62040 2 2006 and EN 62040 1 2008 A1 2013 ...

Страница 17: ...ployee and report the damage to the AEG representative or dealer within eight days of delivery Check the content is complete Check the content is complete Check the content is complete Check the content is complete package UPS Unit x 1 Start up manual x 1 Warranty card x 1 USB cable x 1 RJ45 cable x 1 Input power cord x 1 Output power cord x 1 Please contact your distributor in case of any discrep...

Страница 18: ...r vents The UPS should preferably be operated at room temperature between 15 C and 25 C Install the UPS in a room that is dry relatively dust free and free of chemical vapours Make sure that no magnetic storage media are stored and or operated close to Protect A Check the nameplate to make sure the voltage and frequency data correspond to the values applicable to your loads 4 3 Front Panel Power O...

Страница 19: ...ction 3 RS232 4 AC Input 5 Bypass Surge Protect A 500 700 2 Bypass Surge Protect A 1200 1600 6 3 IEC outlet Protect A 500 700 4 IEC outlet Protect A 1200 1600 7 Fan Protect A 500 LCD Protect A 700 LCD Protect A 1200 LCD Protect A 1600 LCD 1 2 3 4 5 6 4 3 7 5 2 1 6 ...

Страница 20: ...starts to work it will display all information for 3 seconds When in normal mode it will display as below When in AVR mode it will display as below And the mark will flicker every 1 second When in battery mode it will display as below And the mark will flicker every 1 second ...

Страница 21: ...ng used by the protected equipment Each LCD level bar indicates a 25 of the total UPS output capacity 4 5 2 4 5 2 4 5 2 4 5 2 Battery capacity definition Battery capacity definition Battery capacity definition Battery capacity definition Indicate the amount of battery volume remaining Each battery volume level bar indicates a 20 of total battery volume When in off charging mode it will display as ...

Страница 22: ...tion Battery low indication Battery low indication Indicate low battery When battery low on the UPS mark flickers every 1 second 4 5 5 4 5 5 4 5 5 4 5 5 Audio indication Audio indication Audio indication Audio indication Audible Alarm Audible Alarm Audible Alarm Audible Alarm Situation Situation Situation Situation Sounding every 10 seconds Battery Mode Sounding every 1 second Battery Low Sounding...

Страница 23: ...corrosive fumes and conductive contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH 5 3 Connect to Utility and Charge Plug in the AC input cord to the 2 pole 3 wire grounded wall outlet For the best results we suggest charging the battery at least 6 hours with no loa...

Страница 24: ...e UPS 5 4 Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit and devices connected to the UPS will be protected by UPS unit Do not attach a power strip or surge suppressor to the UPS ...

Страница 25: ... start up by using bundled software please connect the UPS and PC with USB cable included NEVER NEVER NEVER NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by motor s devices may cause the damage of the unit 5 7 Turn On Off the Unit Turn on the UPS unit by pressing the power switch Turn off the UPS unit by pressing again the power switch Normally the UPS ...

Страница 26: ...also send warning messages via pager e mail etc Use the bundled CD and follow the on screen instructions to install the software Enter the following serial No to install software 511C1 01220 0100 478DF2A After the software is successfully installed the communication with UPS has been established and a green icon will appear in the system tray Double click the icon to use the monitor software as ab...

Страница 27: ...ormation e g Charging Discharging battery remaining capacity by clicking the battery icon on charging status on discharging status You can set PC s Operating System OS to Sleep Hibernate Shutdown OS or do nothing when it reached Battery Low Level or Battery Critical Level even without any additional software installation 7 SMART BATTERY FUNCTION ...

Страница 28: ... shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery for 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation of battery 3 Replace with the same type of battery Mains normal but LED is flashing Power cord is loose Reconnect the power cord If any abnormal situations occur that are not listed abov...

Страница 29: ...uld be performed are primarily determined by the site conditions Checking the bat Checking the bat Checking the bat Checking the battery tery tery tery Progressive ageing of the battery system can be detected by regular capacity checks Every 12 months perform measurements to compare the achievable standby times e g by simulating a mains failure In this case the load should always have approximatel...

Страница 30: ...ing please contact your dealer immediately Recycle or dispose of the used battery appropriately Never dispose of batteries by burning The batteries might explode If you are not qualified to renew the battery do not try to open the battery cover Leave this work to qualified personnel ...

Страница 31: ...g Packaging Dispose of the stretch plastic film and the moulded parts made from polyethylene foam with normal industrial waste They are chemically inactive and can be disposed of or recycled Metal parts Metal parts Metal parts Metal parts Take metal parts to a scrap metal dealer The equipment housing the lines the inverter the rectifier and the transformers can be recycled via normal routes Electr...

Страница 32: ...terial batteries or battery material batteries or battery material batteries or battery material with refuse Ensure compliance with local legislation and regulations governing the storage handling and disposal of batteries and battery material In the interest of environmental protection and recycling please dispose of the individual system components in accordance with the regulations and legal gu...

Страница 33: ...g nature of these terms we assume liability neither for the accuracy nor completeness of the data provided here Product made in China AEG is a registered trademark used under license from AB Electrolux AEG Power Solutions Emil Siepmann Str 32 I 59581 Warstein Belecke I Germany I Tel 49 180 523 4787 I Fax 49 180 523 4789 I www aegps com Certificate of guarantee Model Serial number Date of purchase ...

Отзывы: