AEG Oxygen Скачать руководство пользователя страница 5

AEG 

installation manual

5

Inlet Hole

Make a hole in the board material for the inlet valve as shown in the fi gure. 
The size of the rectangular opening should be 2 3/8” x 4 3/4” (60mm x 
110mm). In existing houses where tubes are routed underneath, a hole can 
be drilled for the tube using a guide hole as a template. Glue the 90° inlet 
elbow onto the sleeve of the mounting bracket. Leave a gap of approxi-
mately 5/8” (15cm) for the low-voltage cable to be connected to the inlet 
valve. Then the dust tube is glued into the inlet elbow.

Strip off approximately 1” (2cm to 3cm) of the insulation from the end 
of the low-voltage cable. Roll the end of the cable two turns around the 
screws in the inlet valve and tighten the screws. 

Screw the inlet valve into the mounting bracket and make sure that the 
screw does not extend through the tube. If necessary, use shorter screws. 
In a complete wall structure, the mounting bracket is held in place by a 
hook as shown in the fi gure.

Installation in a Brick or Concrete Wall

When installing the inlet valve, sink the pipes, the inlet elbow, and the 
mounting bracket in the wall so that the highest surface of the mounting 
bracket is approximately 1/4” (5mm) deeper than the fi nal inner surface. 
For the tubing system, make a 3 1/8” x 3 1/8” (80mm x 80mm) channel 
in the brick or concrete wall independent of the fi nal thickness of the wall. 
The tubing installation must be sturdy enough so that tubes and parts 
do not move out of their positions later during the installation work. It is 
recommended to cover the opening of the inlet valve to protect it from cast 
material.

fi nished wall surface

wall mounting 
bracket

3 1/8” (80 mm)

pipe

90° elbow

low voltage 

cable

Thread the low voltage cable through the slot 
in the mounting bracket

mounting 

bracket

    

min. 5/8” (15 cm)

wall

The tube can also be installed block / brick 
wall with the rear side. In this case, the wall 
is made imurasiaa for a picture with the hole.

2 3/8”

(60 mm)

4 3/4”

 (110 mm)

2 3/8” (

60 mm)

4 3/4” (

110 mm)

2 1/4”-2 1/2”

(57–62 mm)

Do not disconnect the mounting screws 
completely. Loosen them enough to fi t 
the low voltage cable around them and 
then tighten.

long screw

short screw

inlet vavle

mounting bracket

low voltage cable

90° elbow

pipe

hook

wall

fi nis

Содержание Oxygen

Страница 1: ...Installation manual AEG OXYGEN CENTRAL VACUUM SYSTEM ...

Страница 2: ...m Installation Location of the Power Unit 3 Tubing System Design 3 Location of Wall Inlet Valves 3 Typical Installation Examples 3 Installation of Wall Inlets 4 Tubing System Installation 7 VacPan Installation 8 Exhaust Blow Out 9 Electrical Connections 10 ...

Страница 3: ...single inlet val ve The light broken line indicates an alternative installation type In the house of the same size the power unit is in the garage where the utility valve serves as a third inlet valve allowing you to clean your car for example wall valve door Floor valve wall valve In this example the simplest solution is to route the tubing in the attic If the space is cold the main tube should b...

Страница 4: ...llation is shown in the figure on the right A 90 inlet elbow is used in the wall installation to prevent long objects entering into the tubing system protecting it against blockages A 90 steep elbow can be fitted in two different ways In practice the partition wall can be as narrow as 2 3 4 65mm If the thickness of the wall board is more than 1 25mm you can reach the mounting bracket by using an ext...

Страница 5: ...nstalling the inlet valve sink the pipes the inlet elbow and the mounting bracket in the wall so that the highest surface of the mounting bracket is approximately 1 4 5mm deeper than the final inner surface For the tubing system make a 3 1 8 x 3 1 8 80mm x 80mm channel in the brick or concrete wall independent of the final thickness of the wall The tubing installation must be sturdy enough so that t...

Страница 6: ... needed Drill a hole for the tube also in the floor of the closet Cut the tube to the proper length and glue it into the rebuilding sleeve Insert the tube into the round hole with the floor sleeve rebuilding sleeve first so that it extends through the outer wall of the closet Mount the inlet valve in the rebuilding sleeve Measure and cut the tube to the proper length so that it reaches with the inlet...

Страница 7: ...t notes for installation correct incorrect incorrect pipe collars are attached to the wall wire mesh concrete sand vacuum pipe electrical tube 2 51 mm fire stopping pipe collars E F correct correct incorrect D min 3 4 18 mm push the pipe completely into the fitting C Begin the main tube installation with the farthest inlet valve and place the tubes temporarily at first Do not glue the joints yet unti...

Страница 8: ...ay be generated To reduce the amount of condensation close all pipe holes and inlet open ings using duct tape during installation Before starting to use the central vacuum system for the first time let the system vacuum and circulate fresh air for a few minutes and make sure that there is no water in the dust container If there is water in the container drain it and continue vacuuming until no more...

Страница 9: ...ecause the exhaust tube must be as short as possible it is recommended to place the power unit as close to an outside wall as possible Shown below are examples indicating how to install the exhaust tube The exhaust muffler can be installed upwards downwards as well as horizontally Min 30cm 12 Min 30cm 12 Min 70cm 27 5 ceiling exterior wall ...

Страница 10: ...dden in cast concrete If the cable becomes defective it is also much easier to change it afterwards In these installations only certified electrical components may be used The power unit is connected to an electrical outlet If there is no outlet nearby an electrician will carry out installation All the high voltage connections are under the turbine cover Only an electrician is allowed to open the c...

Страница 11: ...Electrolux Central Vacuum Systems St Göransgatan 143 105 45 Stockholm Sweden ...

Отзывы: