installation manual

3

power unit exhaust

pipe

power unit

wall valve

hose coverage

Location of the Power Unit 

Place the power unit preferably in a heated area like the utility room, 
garage, storage room, or laundry room. If the power unit is installed in a 
cold storage room, the vacuum tubing and the exhaust pipe should be 
insulated in order to avoid condensation. 
In buildings with two or more stories, it is recommended to always place 
the power unit on the lowest fl oor. If the equipment is placed on the upper 
fl oor, the power unit must be more powerful so that even the heaviest 
dust particles can be vacuumed and transferred into the dust container. 
When selecting the installation location, it is recommended that you 
ensure that the placement does not disturb your neighbors or interfere 
with your own comfort and activities. Make sure that there is a wall outlet 
nearby for connection to the electrical network. If you are not sure about 
the placement, contact your local building inspector or fi re authority for 
more information.

Location of Wall Inlet Valves  

Wall inlet valves can be placed in the wall or in the fl oor. Place the inlets 
preferably so that you can reach every corner of the room with a vacuum 
hose that is 27 to 33 feet long (8m to 10m). There is a utility valve in the 
power unit, which allows you to conveniently clean the space where the 
vacuum is located and close-by areas, thus eliminating the need to install 
another inlet valve and tubing route. 

Marking the Placement of the Inlet Valves 

Mark the installation points of the inlet valves in the layout drawings using 
wire of the same length as the actual vacuum hose. When using drawings 
scaled 1:1000 the wire length is 3 1/4” (8 cm), and when using drawings 
scaled 1:50 the wire length is 6 1/2” (16 cm). Suitable places for inlet 
valves are entrance halls, hallways, etc. 

In a typical house only two inlet val-
ves are needed. In such cases, the 
utility valve of the power unit can 
be used for cleaning the basement 
because it often covers the whole 
basement area. 

In this example, the main tube has 
been routed under the house. Ho-
wever, the tube in the under-house 
crawl space should be insulated to 
avoid condensation.

The whole fl oor area can often be 
vacuumed from one single inlet val-
ve. The light, broken line indicates 
an alternative installation type.

In the house of the same size, the 
power unit is in the garage, where 
the utility valve serves as a third 
inlet valve allowing you to clean 
your car, for example.

wall 
valve

door

Floor 
valve

wall 
valve

In this example, the simplest 
solution is to route the tubing in 
the attic. If the space is cold, the 
main tube should be insulated.

It is recommended to place the 
inlet valves in between different 
levels. In such cases, you can ea-
sily clean two levels from one inlet 
valve. The power unit is placed in 
the storage room.

Typical Installation Examples 

Tubing System Design 

The main principle for designing the layout of the tubing system is to 
keep it as short as possible. This will give the highest possible vacuum 
performance. However, the main tube can be routed in different ways. 

The outside diameter of the tubing system is 2” (50.08mm) and is 2 1/8” 
(56mm) at the extension. The through-holes in the walls must be 2 3/16” 
to 2 1/2” (55mm to 60mm) in diameter so that the extension and the low-
voltage cable can also go through the opening. The minimum diameter of 
the exhaust tube is 2 1/8” (56mm). 

New One-Story Houses 

The horizontal main tube is placed in the under-house crawl space or in 
the attic. In the under-house crawl space, the tubing should be insulated. 
Tubes to the inlet valves are routed in the partition walls or between 
secondary spaces, such as closets. In a cold attic, the tubes should be 
covered with insulation in order to avoid condensation.

Two- or Multi-Story Houses 

The main tube is placed in the under-house crawl space, attic, closet, 
between walls, etc. 

Existing Houses 

The main tube can be installed on the surface in existing secondary 
spaces, such as a garage or storage room. The tube can also be routed 
through the attic and then vertically inside the partition walls and closets 
all the way to the inlet valves. A lowered ceiling and closet footings can 
also be used for routing of the tubes.

Read these instructions carefully. Installation of the central vacuum 
system is easy and can be performed with regular hand tools. The 
system can be installed both in new and existing buildings. When 
using a central vacuum system, it is important to make sure there is 
a suffi cient compensation air supply. Normal ventilation ensures that 
there is enough compensation air. This central vacuum system is very 
useful, and you can enjoy it for years to come. 

Содержание Oxygen

Страница 1: ...Installation manual AEG OXYGEN CENTRAL VACUUM SYSTEM ...

Страница 2: ...m Installation Location of the Power Unit 3 Tubing System Design 3 Location of Wall Inlet Valves 3 Typical Installation Examples 3 Installation of Wall Inlets 4 Tubing System Installation 7 VacPan Installation 8 Exhaust Blow Out 9 Electrical Connections 10 ...

Страница 3: ...single inlet val ve The light broken line indicates an alternative installation type In the house of the same size the power unit is in the garage where the utility valve serves as a third inlet valve allowing you to clean your car for example wall valve door Floor valve wall valve In this example the simplest solution is to route the tubing in the attic If the space is cold the main tube should b...

Страница 4: ...llation is shown in the figure on the right A 90 inlet elbow is used in the wall installation to prevent long objects entering into the tubing system protecting it against blockages A 90 steep elbow can be fitted in two different ways In practice the partition wall can be as narrow as 2 3 4 65mm If the thickness of the wall board is more than 1 25mm you can reach the mounting bracket by using an ext...

Страница 5: ...nstalling the inlet valve sink the pipes the inlet elbow and the mounting bracket in the wall so that the highest surface of the mounting bracket is approximately 1 4 5mm deeper than the final inner surface For the tubing system make a 3 1 8 x 3 1 8 80mm x 80mm channel in the brick or concrete wall independent of the final thickness of the wall The tubing installation must be sturdy enough so that t...

Страница 6: ... needed Drill a hole for the tube also in the floor of the closet Cut the tube to the proper length and glue it into the rebuilding sleeve Insert the tube into the round hole with the floor sleeve rebuilding sleeve first so that it extends through the outer wall of the closet Mount the inlet valve in the rebuilding sleeve Measure and cut the tube to the proper length so that it reaches with the inlet...

Страница 7: ...t notes for installation correct incorrect incorrect pipe collars are attached to the wall wire mesh concrete sand vacuum pipe electrical tube 2 51 mm fire stopping pipe collars E F correct correct incorrect D min 3 4 18 mm push the pipe completely into the fitting C Begin the main tube installation with the farthest inlet valve and place the tubes temporarily at first Do not glue the joints yet unti...

Страница 8: ...ay be generated To reduce the amount of condensation close all pipe holes and inlet open ings using duct tape during installation Before starting to use the central vacuum system for the first time let the system vacuum and circulate fresh air for a few minutes and make sure that there is no water in the dust container If there is water in the container drain it and continue vacuuming until no more...

Страница 9: ...ecause the exhaust tube must be as short as possible it is recommended to place the power unit as close to an outside wall as possible Shown below are examples indicating how to install the exhaust tube The exhaust muffler can be installed upwards downwards as well as horizontally Min 30cm 12 Min 30cm 12 Min 70cm 27 5 ceiling exterior wall ...

Страница 10: ...dden in cast concrete If the cable becomes defective it is also much easier to change it afterwards In these installations only certified electrical components may be used The power unit is connected to an electrical outlet If there is no outlet nearby an electrician will carry out installation All the high voltage connections are under the turbine cover Only an electrician is allowed to open the c...

Страница 11: ...Electrolux Central Vacuum Systems St Göransgatan 143 105 45 Stockholm Sweden ...

Отзывы: