![AEG LAVATHERM 56740 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/aeg/lavatherm-56740/lavatherm-56740_user-manual_10163019.webp)
1. Unscrew cover above the bulb (this can be found directly behind the loading aperture,
at the top; refer to “Description of machine” section.)
2. Replace defective bulb.
3. Screw cover back down.
Check the correct positioning of o-ring gasket before screwing back the door light cover.
Do not operate the dryer when missing o-ring gasket on door light cover.
WARNING!
For safety reasons, the cover must be screwed down tightly. If this is not done, the dryer
must not be operated.
Machine settings
Setting
Implementation
Buzzer permanent
on/off
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE and LONG ANTI-CREASE buttons
and hold down for approx. 5 seconds.
– diode above BUZZER button starts lighting - buzzer permanently
on.
– lighting diode comes off - buzzer permanently off.
3. The buzzer is by default always off. You can use the BUZZER button
to activate or deactivate sound but the machine does not memorize
your selection.
Water hardness
1)
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE and TIME buttons and hold down
for approx. 5 seconds. The current setting is on the display:
–
low conductivity <300
S/cm
–
medium conductivity 300-600
S/cm
–
high conductivity >600
S/cm
3. Press the START PAUSE button sequentially until you set desired level.
4. To memorize setting press simultaneously the DELICATE and TIME
buttons or turn knob to OFF position
Emptying water res-
ervoir - warning LED
off
2)
1. Turn the programme selector to any programme.
2. Press simultaneously the LONG ANTI-CREASE and TIME buttons and
hold down for approx. 5 seconds.
The current setting is on the display:
– warning
icon and
- warning message is off
– warning
icon and
- warning message is switched on
1)
Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to
geographical locations thus varying its conductivity values. Relevant variations of the conductivity of the water
compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the
end of the cycle. Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity
values of the water.
2)
By default the warning LED is always on at the end of the drying cycle or during the cycle if the water reservoir
is full. When using an external drain for the condensed water warning can be offi