The inlet hose must not be lengthened. If it is too short and you do not
wish to move the tap, you will have to purchase a new, longer hose spe-
cially designed for this type of use.
Water drainage
The end of the drain hose can be positioned in three ways:
Hooked over the edge of a sink using the plastic hose guide sup-
plied with the machine.
In this case, make sure the end cannot come
unhooked when the machine is emptying.
This could be done by tying it to the tap
with a piece of string or attaching it to the
wall.
In a sink drain pipe branch.
This branch
must be above the trap so that the bend is
at least 60 cm above the ground.
Directly into a drain pipe at a height
of
not less than 60 cm and not more than
90 cm.
The end of the drain hose must always be
ventilated
, i.e. the inside
diameter of the drain pipe must be larger than the outside diameter of
the drain hose.
The drain hose
must not be
kinked. Run it
along the floor;
only the part near
the drainage
point must be
raised.
48
Installation
132993360 gb.qxd 10/25/02 9:27 AM Pagina 48 (Nero/Process Black pellicola)