BURNER
Ø BYPASS 1/100 mm
Semi-rapid
32
Auxiliary
28
9.3
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 13 kW
Gas replacement:
G30 (3+) 28-30 mbar = 931 g/h
G31 (3+) 37 mbar = 914 g/h
Electric supply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category:
II2H3+
Gas connection:
R 1/2"
Appliance class:
3
9.4
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Triple Crown
4,0
1,4
146
Rapid
3,0
0,75
119
Semi-rapid
2,0
0,45
96
Auxiliary
1,0
0,33
70
9.5
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0
1,4
98
291
286
Rapid
2,8
0,75
86
204
200
Semi-rapid
2,0
0,45
71
145
143
Auxiliary
1,0
0,33
50
73
71
www.aeg.com
18
Содержание HG956440
Страница 1: ...USER MANUAL EN User Manual Hob HG956440 ...
Страница 21: ...ENGLISH 21 ...
Страница 22: ...www aeg com 22 ...
Страница 23: ...ENGLISH 23 ...
Страница 24: ...www aeg com shop 867329002 C 012017 ...