![AEG EWH 100 Trend Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/aeg/ewh-100-trend/ewh-100-trend_operation-and-installation_8549020.webp)
20
Installation - for contractors
15.
Specification
15.1
Dimensions and connections
h46
c01
c06
i13
b01
a10
100
a40
a30
61
23
D
00000
37
13
3
ewH 30
Trend
ewH 50
Trend
ewH 80
Trend
ewH 100
Trend
ewH 120
Trend
ewH 150
Trend
ewH 200
Trend
a10 Appliance
Height
mm
642
897
871
1025
1178
1410
1715
a30 Appliance
Depth
mm
410
410
520
520
520
520
520
a40 Appliance
Diameter
mm
405
405
510
510
510
510
510
b01 Entry electrical cables
Threaded fitting
PG 16
PG 16
PG 16
PG 16
PG 16
PG 16
PG 16
c01 Cold water inlet
Male thread
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Rear clearance
mm
85.5
85.5
95
95
95
95
95
c06 DHW outlet
Male thread
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Rear clearance
mm
85.5
85.5
95
95
95
95
95
h46 Temperature indicator
i13 Wall mounting bracket
Height
mm
530
590
585
735
890
1125
1425