Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed at least once every 4 months, or
when led H starts to flash. The alarm signal only appears when the Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button G.
• Within 5 seconds, press Button H until Led H flashes in confirmation:
• Led flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• Led flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
Changing the Activated Charcoal Filter
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press button H.
Changing the Filter
• Open the comfort panels pulling them downwards.
• Remove the metal grease filters.
• Remove the saturated charcoal filter by releasing the fixing
hooks
• Fit the new filter and fasten it in its correct position.
• Put the metal grease filters in their seats.
• Close the comfort panels.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Refit the Support, fixing it in place with the two screws re-